Skip to main content
OpenTrials
Completed

NCT Number: NCT01336101

Evaluation of Efficacy of the EPIC™ Self-Expanding Nitinol Vascular Stent

The intent of this clinical registry is to demonstrate the efficacy of the EPIC™ stent in patients with superficial femoral/ popliteal artery disease.

100 patients with symptomatic femoropopliteal artery lesion will be enrolled in the study and shall undergo 4 visits during the trial -a pre-procedure visit, procedure visit at which time the stent will be placed, and follow-up visits at 6 and 12 months.

Study hypothesis: The EPIC™ Self-Expanding Nitinol Vascular Stent with Delivery System will be efficacious in patients with Superficial Femoro/Popliteal Artery disease.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Herz-Zentrum, Bad Krozingen, Germany

Loading trial locations.

About this study

The SUMMIT Registry addresses the treatment of peripheral arterial disease (PAD).

PAD represents a major challenge to physicians in treating the Superficial Femoral (SFA) and Popliteal arteries. These vessels are exposed to enormous mechanical stress what represents a harsh environment for any endovascular device. During flexing of the knee, the SFA/Popliteal arteries can bend, rotate, elongate and compress dramatically. An ideal stent designed for use in the SFA/Popliteal arteries would offer great ranges of movement while adequately supporting the arteries.

Subject of study is the EPIC™ Femoropopliteal Self-Expanding Stent System which provides a great range of motions for a highly flexible femoral artery while adequately supporting the vessel.

Primary objective is to evaluate the efficacy of the device in treating lesions of the SFA/Popliteal artery.

The project is a multi-centre open label study. Primary efficacy parameter will be assessed by measuring the in-stent binary stenosis using duplex ultrasound at 6 and 12 months after the stent placement. Binary restenosis is defined as a peak systolic velocity ratio (PSVR) ≥2.5:1.

Anticipated study duration is 18 months: 6 months recruiting and 12 months follow-up.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subjects, male or female, must be between the ages of 18 to 85 years inclusive at the time of consent. A female of childbearing potential may be enrolled, provided she has a negative pregnancy test at Screening.
  • Subjects must give written informed consent prior to participation in the study and must understand the purpose of this study and be willing to adhere to the study procedures described in this protocol.
  • Rutherford Classification Category 2-4
  • Single de novo lesion in the superficial femoro/popliteal artery
  • Disease segment length ≤150mm
  • >70% diameter stenosis and occlusion
  • Patent ipsilateral iliac artery
  • Patent ipsilateral popliteal artery and at least 1 patent tibial artery in continuity to ankle
  • Target reference vessel diameter 3.5-7.5 mm

Exclusion criteria

  • Target lesion previously treated with a stent or surgery.
  • Rutherford Classification Category 0, 1, 5 or 6.
  • Inability to tolerate antithrombotic or antiplatelet therapies.
  • Pregnancy.
  • Other co morbidity risks which in the opinion of the investigator limit longevity or likelihood of complying with protocol follow up.
  • Serum creatinine > 2.5 mg/dL.
  • Myocardial infarction or stroke within 90 days of enrollment.
  • Hypercoagulable state.
  • Uncontrollable hypertension.
  • Patients currently enrolled in any other clinical trial(s).

Treatment and study plan

EPIC™ Self-Expanding Nitinol Vascular Stent

Device

SFA/Popliteal Artery stenting

Primary outcomes

  1. efficacy of the EPIC™ Stent as measured by the in-stent binary restenosis using duplex ultrasound (DUS)

    Time frame: at 6 months after procedure

    Binary restenosis is defined as a peak systolic velocity ratio (PSVR) ≥2.5:1.

  2. efficacy of the EPIC™ Stent as measured by the in-stent binary restenosis using duplex ultrasound (DUS)

    Time frame: at 12 months after procedure

    Binary restenosis is defined as a peak systolic velocity ratio (PSVR) ≥2.5:1.

Secondary outcomes

  1. Technical Success

    Time frame: after stent placement intra-procedural via angiographic images (day 1)

    defined as the ability to implant the stent with a residual angiographic stenosis no greater than 30%.

Sponsors and collaborators

Lead sponsor

Provascular GmbH

Other

Collaborators

  • Boston Scientific Corporation

Registry information

Official study title

Evaluation of Efficacy of the EPIC™ Self-Expanding Nitinol Vascular Stent With Delivery System -The SUMMIT Registry

Acronym: SUMMIT

Important dates

Study start
2011
Primary completion
2012
Study completion
2012
First posted
Apr 15, 2011
Registry last updated
Apr 24, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.