Skip to main content
OpenTrials
Completed

NCT Number: NCT04777513

Evaluation of Diagnostic Accuracy, Safety, and Cost-Effectiveness of the Non-Invasive Cardiolens FFR-CT Pro Method to Measure the Fractional Flow Reserve in Diagnostics of Chronic Coronary Syndromes Versus the Standard Diagnostic Modalities.

A multicentre, post-marketing, observational trial in 450 patients, whose standard diagnostic workup for chronic coronary syndromes provided for Invasive Coronary Angiography (ICA). Medical records of a potential subject of the trial before their enrolment contain a good quality result of at least 128-slice CCTA performed up to 3 months before the elective ICA. CCTA should find at least one ≥50% stenosis in at least one big coronary artery of ≥ 2 mm diameter. At one hour before ICA in the latest the patient should have a resting Continuous Non-Invasive Blood Pressure (CNBP) taken with a certified device delivered by LifeFlow. The last criterion before including a patient in the final analysis is at least one significant (≥50%) stenosis in one or two coronary arteries of ≥ 2 mm diameter visually confirmed by ICA with a FFR measurement taken in these arteries.

The data collection period will cover time from admission for the elective ICA to discharge from the hospital (evaluation of possible adverse events related to invasive procedures).

After initial qualification of available data by the attending physician, selected patients will be asked for a consent to participation in the trial no later than upon admission for the elective ICA and before CNBP measurement.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

American Heart of Poland, Centrum Kardiologii i Kardiochirurgii w Bielsku-Białej, Bielsko-Biala, Poland

Loading trial locations.

About this study

Stage 1

After a patient declares their consent, a doctor or another member of the study team trained by the sponsor will perform procedures in the following order:

  • Define the unique patient ID to be recorded in the CRF with the patient's demographic data
  • Assess the quality of CCTA imaging data (DICOM) according to guidelines agreed upon with the sponsor and record the number and location of the significant (≥50%) stenosis sites in the CRF based on CCTA
  • No later than one hour before ICA starts, perform a physical examination consisting in instantaneous peripheral blood pressure (systolic and diastolic) resting measurement performed with a standard sphygmomanometer and Continuous Non-Invasive Blood Pressure measurement (1-3 min).

Stage 2

After the procedures mentioned above are performed, the patient will undergo elective ICA with the outcomes, i.e.:

  • video material showing the location of the wire during the FFR measurement,
  • digital pressure signals exported from the FFR measuring device used to determine the value of the invasive FFR,
  • values of FFR measurements obtained during ICA will be entered after being anonymised in a dedicated HEMOFLOW PMS_2020 reference database.

Stage 3

Within 48 hours of ICA completion a doctor or another member of the study team trained by the sponsor:

  • will enter the following data in the Cardiolens FFR-CT Pro system:
  • Patient's data, i.e. patient's ID, gender, height, body mass, exercise tolerability, information on used medications and smoking cigarettes. Optionally, i.e. if upon admission for ICA a blood test was performed as a part of the standard diagnostic workup - haematocrit levels and total protein concentration
  • Files containing CCTA imaging data in the DICOM format.
  • Values of instantaneous peripheral blood pressure (systolic and diastolic) resting measurement performed with a standard sphygmomanometer as well as the digital signal obtained during the CNBP measurement (1-3 min)
  • Based on the CCTA description or meta data contained in the imaging data the doctor or another member of the study team will record the following information in the CRF:
  • Radiation dose during CCTA
  • Contrast medium dose during CCTA
  • Will enter the following information in the CRF:
  • Radiation dose during the diagnostic part of ICA
  • Contrast medium dose during the diagnostic part of ICA
  • Number and type of adverse events
  • Duration of the diagnostic workup.

Stage 4

Within 7 days of entering all the stage 3 data the investigator (a cardiologist) trained by the sponsor will measure the value of the virtual FFR with the Cardiolens FFR-CT Pro system at locations corresponding to ICA FFR measurements (based on video recording entered in the database during stage 2)

Based on results obtained from the Cardiolens FFR-CT Pro system vs reference data an analysis will be performed on meeting the primary and secondary end points of the trial.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥ 18
  • Declaration of informed consent to sharing medical records gathered during the standard diagnostic workup
  • History of chronic coronary syndromes (CCS)
  • Diagnostic CCTA (good quality test allowing investigation of the entire coronary artery tree), showing at least one site with stenosis ≥50% of the lumen in a large coronary artery of ≥ 2 mm diameter, with no prior revascularisation
  • Standard treatment of chronic coronary syndromes with no dosage modification required within at least 4 weeks before the enrolment
  • Patients with a prior acute coronary syndrome (ACS) or revascularisation would be found eligible under the following conditions:
  • Over 30 days from the acute coronary syndrome occurrence
  • FFR assessment during ICA may only cover the vessels that were not revascularized (both PCI and CABG) and were not the reason of ACS
  • No closed coronary arteries

Exclusion criteria

  • CCTA-confirmed myocardial bridges causing >50% stenosis of the epicardial vascular lumen
  • Coronary obstruction confirmed by CCTA or invasive coronarography
  • History of ACS with coronary angioplasty or Coronary Artery Bypass Grafting (CABG) performed unless point 6 conditions are met
  • Significant haemodynamic abnormalities of the valve or history of surgical correction of the defect or CABG
  • Second-degree or third-degree atrioventricular block, sinus node dysfunction, QTc > 450 ms or prolonged QTc
  • LVEF ≤ 35% found in an echocardiogram performed within the last 6 months
  • BMI ≥ 35
  • Clinically apparent infection
  • Thrombocytopenia below 100.000/mm3
  • Active neoplastic disease (apart from basal cell carcinoma and carcinoma in situ) and other conditions, which, in the investigator's opinion significantly affect their life expectancy
  • Other significant conditions, infections, addictions and psychological or social factors, which, in the doctor's opinion, may affect patient's ability to participate in the trial or significantly affect their safety

Treatment and study plan

CCTA (Coronary Computed Tomography Angiography)

Procedure

Per the protocol, patients had a coronary computed tomography angiography within standard of care before the enrollment to the study.

ICA (Invasive Coronary Angiography)

Procedure

Per the protocol, patients will have an Invasive Coronary Angiography within standard of care.

FFR (Fractional Flow Reserve)

Procedure

Per the protocol, patients will have a Fractional Flow Reserve procedure within standard of care.

CNBP measurement

Device

Per the protocol, patients will have the measurement of the resting Continuous Non-Invasive Blood Pressure (CNBP). The signal is required for iSIL-FFR technology.

Cardiolens FFR-CT Pro

Device

Per the protocol, non-invasive FFR measurements will be perfomed via Cardiolens FFR-CT Pro technology for the enrolled patients.

Primary outcomes

  1. The evaluation of the increased diagnostic accuracy of the non-invasive Cardiolens FFR-CT Pro technology

    Time frame: Up to 18 months

    Evaluation of the increased diagnostic accuracy (area under ROC curve, AUC) in detection of haemodynamically significant stenoses in coronary arteries with a non-invasive Cardiolens FFR-CT Pro technology compared to CCTA in reference to the invasive fractional flow reserve (FFR) testing at the arterial level.

Secondary outcomes

  1. The evaluation of diagnostic accuracy of the non-invasive Cardiolens FFR-CT Pro technology

    Time frame: Up to 18 months

    Evaluation of diagnostic accuracy of Cardiolens FFR-CT Pro in detection of haemodynamically significant stenoses in coronary arteries (FFR value ≤0.80) compared to CCTA (stenosis ≥ 50%), in reference to the invasive FFR testing at the patient and arterial level, based on parameters like sensitivity, specificity, positive/negative predictive value, accuracy at the patient and arterial level.

  2. The evaluation of safety of the non-invasive Cardiolens FFR-CT Pro technology

    Time frame: Up to 5 days. The date from admission for the scheduled ICA to discharge from the hospital.

    Evaluation of safety of the non-invasive Cardiolens FFR-CT Pro technology (the result of the non-invasive test completes the diagnostic workup for coronary disease) compared to the standard diagnostics in chronic coronary syndromes based on the following parameters:

    • Radiation dose during the diagnostic workup
    • Contrast medium dose in the diagnostic workup
    • Adverse events during the diagnostic workup
    • Duration of the diagnostic workup
  3. The evaluation of the costs of Cardiolens FFR-CT Pro technology

    Time frame: Up to 5 days. The date from admission for the scheduled ICA to discharge from the hospital.

    • Evaluation of the costs of Cardiolens FFR-CT Pro in diagnostics of chronic coronary syndromes compared to the standard diagnostic workup (the sum of the costs for individual diagnostic modalities according to the National Health Fund reimbursement prices as well as Procedural Reimbursement Payment Guide)

Sponsors and collaborators

Lead sponsor

Hemolens Diagnostics Sp. z o.o.

Other

Collaborators

  • GENELYTICA Sp. z o.o.

Registry information

Official study title

Evaluation of Diagnostic Accuracy, Safety, and Cost-Effectiveness of the Non-Invasive Cardiolens FFR-CT Pro Method to Measure the Fractional Flow Reserve in Diagnostics of Chronic Coronary Syndromes Versus the Standard Diagnostic Modalities. A Multicentre Post-marketing Trial of a Class 2a Medical Device, Cardiolens FFR-CT Pro - Software for Non-invasive Determination of Haemodynamic Parameters in Coronary Arteries.

Important dates

Study start
2020
Primary completion
2022
Study completion
2023
First posted
Mar 2, 2021
Registry last updated
May 16, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.