NCT Number: NCT02608281
Clinical study to evaluate diagnostic accuracy of low dose contrast enhanced dual energy mammography imaging (CEDEM+PRIME) in comparison with CE-MRI The primary objective of this clinical study is to assess diagnostic accuracy in breast cancer detection in Contrast Enhanced Dual Energy Mammography compared to CEMRI. Sensitivity and specificity will be compared for both modalities.
Looking for future studies?
Notify Me21 year and older
Female
Interventional
Not applicable
Vienna, 1090, Austria
STUDY OBJECTIVES The primary objective of this clinical study is to assess the value of low-dose CEDEM in comparison with CE-MRI. The diagnostic accuracy in breast cancer detection of low dose CEDEM will be evaluated.
Investigator plans to explore the diagnostic quality of 4 standard view bilateral dual energy subtracted images compared to CE-MRI in a blinded reader study. A goal is to evaluate, whether sensitivity and specificity of low-dose CEDEM are comparable with breast MRI.
Subjects will be asked before diagnostic workup to participate in this clinical study. Approximately 80 subjects scheduled for a diagnostic CE-MRI (i.e., based on screening mammography classified as BI-RADS® 0, 4 or 5), will be eligible to participate in this study and will undergo a follow up 4 view bilateral low dose contrast enhanced mammography procedure.
Radiologically, subjects included in the study population will have even distribution of masses, clusters of microcalcifications, and architectural distortions as given by the nature of breast cancer development.
The study population will include all breast compositions. Diagnostic CE-MRI Examination If eligible, subjects with a positive or incomplete screening mammogram (BI-RADS 0, 4 or 5) will undergo a CE-MRI of the breast. MRI examinations will be performed on a 3 Tesla scanner (Tim trio, Siemens) with a dedicated 16 channel breast coil. A combination of high temporal and high spatial resolution imaging protocol will be used. All patients will be examined in the prone position and contrast agent (0.2mmol / body weight, GD-DOTA) will be administered i.v. as a bolus followed by a 20 ml saline flush.
Both exams (CEDEM and CE-MRI) will be scheduled in the second week of the menstrual cycle in premenopausal women. Each suspicious lesion will undergo needle or surgical biopsy (after completion of the CEDEM+PRIME procedure). Imaging findings will be compared with findings of histology.
Diagnostic CEDEM+PRIME If eligible, subjects with a completed MRI procedure will undergo a 4 standard view (CC, MLO) bilateral CEDEM examination. Due to use of the grid-less PRIME acquisition technology the AGD is limited and lies in the range of a standard mammogram. The high energy images will be acquired with the titanium filter. All acquired images - including the unprocessed images - will be collected. Recombined CEDEM images will be created offline. Contrast agent is injected as a bolus of 2 ml/kg body weight of non-ionic iodine contrast media with a power injector at a rate of 3.5ml/s followed by a 25ml saline flush.
The CEDEM diagnostic procedure will be performed not later than 7 days and at least 24 hours after the CE-MRI procedure.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The CEDEM application requires the intravenous injection of iodide contrast agents. For each projection view (CC, MLO) a low and a high energy x-ray image will be acquired after Iodine based contrast medium administration. Patient will undergo CE MRI procedure.
Time frame: 24 months
Difference in accuracy of 11% comparing a 4-view contrast-enhanced dual energy imaging to CE-MRI assuming 11% discordant rate in the diagnosis
Time frame: 24 months
The ROC area will be estimated from the BI-RADSS scores assigned by the readers to each suspicious lesion. The BI-RADS scores assigned by the readers in the interpretation of a CEDEM lesion will be used for the CEDEM+PRIME ROC area; the BI-RADS scores assigned by the readers in the interpretation of a CE-MRI case per lesion will be used for the CE-MRI ROC area. A receiver operating characteristic (ROC), or ROC curve, is a graphical plot that illustrates the performance of a binary classifier system as its discrimination threshold is varied. The curve is created by plotting the true positive rate (TPR) against the false positive rate (FPR) at various threshold settings
Siemens Healthcare QT
Industry
Clinical Study to Evaluate Diagnostic Accuracy of Low Dose Contrast Enhanced Dual Energy Mammography Imaging in Comparison to CE-MRI
Acronym: CEDEM
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05989022
Breast Cancer Diagnosis, Breast Diseases
Regensburg, Bavaria, Germany
View Trial DetailsNCT01885741
Breast Cancer Diagnosis, Breast Cancer Screening
Hamilton, Ontario, Canada
View Trial DetailsNCT01952717
Breast Cancer Diagnosis, Breast Diseases
View Trial DetailsNCT06559059
Breast Cancer Diagnosis, Breast Diseases
Brooklyn, New York, United States
View Trial Details