Skip to main content
OpenTrials
Completed

NCT Number: NCT04722432

Evaluation of Deployment Capability and Accuracy of an Outside the Scope (OTS), Detachable Catheter System for Ablation of Peripheral Lung Lesions: An Ex-Vivo Human Lung Model Study

A novel OTS detachable probe system carried outside and along the flexible bronchoscope has been developed. Using this novel system, the operator can deploy the probe in the target bronchus and lesion and completely detach the scope from the probe.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

CHUM

Montreal, Quebec, Canada

About this study

Lung ablative therapies have growing interest in the treatment of early-stage primary lung cancer in surgical high-risk patients and as part of multimodal treatment in patients with large lesions or metastatic malignant disease in the lungs. Endobronchial ablative strategies allow deliver y of these therapies through a natural orifice and minimally invasive approach, potentially improving safety and reducing related morbidity. Application and deployment of this system allows the operator to have constant control of the airway, preventing life-threatening hemoptysis and other complications. We hypothesize that this novel detachable OTS system can be successfully deployed in the peripheral parenchymal target with potential clinical applications in the near future.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients who follow surgery for the removal of diseased lungs before being submitted to a bilateral lung transplant.

Exclusion criteria

  • None

Treatment and study plan

Outside the Scope (OTS), Detachable Catheter System

Device

Evaluation of Deployment Capability and Accuracy of an Outside the Scope (OTS), Detachable Catheter System for Ablation of Peripheral Lung Lesions: An Ex-Vivo Human Lung Model Study

Primary outcomes

  1. accuracy of the deployment method

    Time frame: Time of procedure

    will be measured by bidimensional fluoroscopy images (antero-posterior and latero-lateral). The deployment will be considered successful if the tip of the probe is positioned at a distance less than 5 mm in both axes from the target model and stay stable in place over 5 minutes of ventilation.

Sponsors and collaborators

Lead sponsor

Centre hospitalier de l'Université de Montréal (CHUM)

Other

Registry information

Important dates

Study start
2020
Primary completion
2023
Study completion
2023
First posted
Jan 25, 2021
Registry last updated
Feb 2, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.