Skip to main content
OpenTrials
Completed

NCT Number: NCT02843477

Evaluation of Corrected Carotid Artery Flow Time as a Predictor of Fluid Responsiveness in Spontaneous Breathing Patients

It is still challenging to assess intravascular volume status in spontaneously breathing patients. Recently, the measurement of corrected flow time in carotid artery was introduced as quite useful, simple and noninvasive for the evaluation of circulating blood volume change. The aim of this study is to evaluate whether corrected carotid artery flow time as determined by ultrasonography can be a predictor of fluid responsiveness in spontaneously breathing patients before induction of general anesthesia.

Completed

Looking for future studies?

Notify Me

Key information

Age range

19 year–80 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institue, Yonsei Universiy College of Medicine

Seoul, 03722, South Korea

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • adult patients (19-80 years of age) who were scheduled to undergo elective neurosurgery for brain tumor

Exclusion criteria

  • BMI > 35 or < 15 kg/m2
  • the presence of carotid artery stenosis > 50%
  • systolic blood pressure > 160 mmHg
  • cardiac rhythm other than sinus
  • intracardiac shunt 6. valvular heart disease
  • a left ventricular ejection fraction of < 50%
  • right ventricular dysfunction 9
  • chronic obstructive pulmonary disease
  • pulmonary hypertension
  • chronic kidney disease (eGFR < 60 mL/min/1.73m2)
  • pregnancy

Treatment and study plan

ultrasonographic measurement of corrected flow time in carotid artery

Device

Corrected carotid artery flow time is measured using 10-5 MHz linear probe on a portable ultrasound machine. On the two-dimensional image, the optimal image of the long-axis view is obtained at the left common carotid artery. The sample volume is placed on the center of the lumen, 2 cm proximal to the bulb, and a pulsed wave Doppler examination was performed while the Doppler beams were adjusted to ensure < 60° of angle for the best signal. Then, cardiac cycle time and carotid flow time is measured. Carotid flow time is measured between the upstroke of the flow tracing and the dicrotic notch, and it is corrected for pulse rate by dividing flow time by the square root of the cardiac cycle time to calculate corrected carotid artery flow time (flow time/√cycle time).

Primary outcomes

  1. ultrasonographic measurement of corrected flow time in carotid artery

    Time frame: right before fluid loading

    The ultrasonographic measurement of corrected flow time in carotid artery will be performed before fluid loading.

  2. ultrasonographic measurement of corrected flow time in carotid artery

    Time frame: 5 minutes after fluid loading

    The ultrasonographic measurement of corrected flow time in carotid artery will be performed 5 minutes after fluid loading.

Sponsors and collaborators

Lead sponsor

Yonsei University

Other

Registry information

Important dates

Study start
2016
Primary completion
2017
Study completion
2017
First posted
Jul 25, 2016
Registry last updated
Jul 17, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.