The left atrium appendage (LAA) is a remnant of the original embryonic left atrium formed during the third week of gestation. LAA is believed to function as a decompression chamber during left ventricular systole and other periods when left atrial pressure is elevated. The LAA is also a major endocrine organ and is the main producer of ANP (atrial natriuretic peptide) in the human heart. The ANP concentration is 40 times higher in the LAA walls than in the rest of the atrial wall. A study of patients having undergone the maze procedure and associated LAA removal found a significantly lower ANP secretion and an increase in salt and water retention. Whether this could eventually lead to hypertension or heart failure symptoms is not known.
Removal of the LAA is routinely performed during antiarrhythmic surgical techniques ("MAZE surgery") to reduce the risk of subsequent LAA thrombus. Furthermore, new percutaneous ablation techniques target LAA to reduce further risks of atrial fibrilation recurrences. However, in addition to effects on diastolic atrial function and atrial natriuretic peptide (ANP) secretion, this could potentially reduce stroke volume and cardiac output and may thus promote heart failure. Its removal could be particularly detrimental in patients with existing heart failure and high intraatrial pressure, as it would further promote pulmonary congestion and also reduce their cardiac output.
The study will be conducted at the CHU Brugmann Hospital, with collaboration between cardiac surgery and cardiology wards. Subjects referred for non valvular cardiac surgery will be prospectively included during the first 6 months following the onset of the protocol. Echocardiographic and invasive data will be collected simultaneously.
The goals of the study are:
* To evaluate the immediate impact of temporary closure of the LAA using a vascular clamp in the beating heart of human subjects during cardiac surgery. Impact of LAA occlusion will be measured using transesophageal echocardiography and hemodynamic measurement of the cardiac output. * To correlate echocardiographic parameters with in situ hemodynamic data.
A significant role of the LAA in the cardiac hemodynamic including the left ventricle outflow might have different clinical implications and will raise questions about:
* Appropriateness of LAA resection in antiarrhythmic surgery * Importance of restoring sinus rhythm in atrial fibrilation patients * Importance to spare LAA from ablation during atrial fibrilation ablation to avoid significant consequences on cardiac function. * Appropriateness of the LAA occluding device in atrial fibrillation patients.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Brussels, 1020, Belgium
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann. A transesophageal echocardiogram (TEE) will be performed and the TEE probe will stay continuously during the entire procedure, to allow all necessary measurements.
All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann.During the procedure, a thermistor-tipped catheter (model 93A-131-7F, Edwards, Santa Ana, CA) will be inserted into the pulmonary artery to measure right atrial pressure (Pra), pulmonary arterial pressure (Ppa), Ppao and thermodilution cardiac output. Ringer's lactate will be infused to maintain an occluded pulmonary arterial pressure (Ppao) of 8-10 mmHg.
All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann.During the procedure, a pressure/volume catheter (CD Leicom, Zoetermeer, Netherland) will be placed in the left ventricle through a left superior pulmonary vein purse string, in order to measure alternatively LV pressure/volume loops and LA pressure.
A complete transthoracic echocardiography will be performed the day before the surgical procedure. It will establish the presence of the inclusion and exclusion criteria, as stipulated above. This will be done using a Philips IE33 echocardiograph (Koninklijke Philips Electronics N.V., Netherlands).
During the surgical procedure, a transesophageal echocardiogram will be performed, using an Acuson Sequoia system (Siemens AG, Germany).
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. LV contractility will be estimated from the slope of the end-systolic pressure-volume relation.
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. LV contractility will be estimated from the slope of the end-systolic pressure-volume relation.
Time frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Time frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: AFS 2CME90°= (Amax-Amin)/Amax.
Time frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: AFS 2CME90°= (Amax-Amin)/Amax.
Time frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: LAA ejection volume= 3,14*D1*D2*TVI PW LAA/4, where D1 and D2 are the diameters of the opening of the LAA at 0° and 90°
Time frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: LAA ejection volume= 3,14*D1*D2*TVI PW LAA/4, where D1 and D2 are the diameters of the opening of the LAA at 0° and 90°
Time frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: Stroke volume= 3,14D²*Aortic PW TVI /4, where D is the LVOT (left ventricular outflow tract)diameter in A3C.
Time frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: Stroke volume= 3,14D²*Aortic PW TVI /4, where D is the LVOT (left ventricular outflow tract) diameter in A3C.
Time frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). 2C ME 90° measure
Time frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). 2C ME 90° measure
Time frame: Baseline (before LAA clamping)
Transgastric or deep transgastric aortic Pulse Wave Doppler. 2C ME 90° measure
Time frame: 5 minutes after LAA clamping
Transgastric or deep transgastric aortic Pulse Wave Doppler. 2C ME 90° measure
Time frame: Baseline (before LAA clamping)
Amplitude A wave: measured with DTI (Tissue Doppler ) 4C ME 0° lateral ring
Time frame: 5 minutes after LAA clamping
Amplitude A wave: measured with DTI (Tissue Doppler ) 4C ME 0° lateral ring
Time frame: Baseline (before LAA clamping)
Measured by aortic Pulse Wave (PW) Doppler flow
Time frame: 5 minutes after LAA clamping
Measured by aortic Pulse Wave (PW) Doppler flow
Brugmann University Hospital
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05345639
Agnosia, Bites and Stings
Angers, maine et loire, France
View Trial DetailsNCT03772990
Cardiac Surgery, Cardiopulmonary Bypass
Manama, Bahrain
View Trial DetailsNCT07725445
Arrhythmias, Cardiac, Cardiac Arrhythmias
Seoul, South Korea
View Trial DetailsNCT07736066
Cardiac Rehabilitation, Cardiac Surgery
Seoul, South Korea
View Trial Details