San Diego State University, Audiology Clinic
San Diego, California, 93402, United States
NCT Number: NCT03686046
Determining acceptability and usability of a wearable open-source speech processing platform (Master Hearing Aid) developed for hearing-aid research
Looking for future studies?
Notify Me30 year–90 year
All sexes
Observational
San Diego, California, 93402, United States
Part 1 Speech perception tests. You will hear words and sentences under a variety of listening conditions and be asked either to either repeat them or to select what you heard from a set of options. You will also answer a few questions about the speech and the background noise. The goal is to determine the ability of the most recent version of the device to deliver good quality speech that is comfortable and understandable over a range of conditions that are representative of everyday listening.
Part 2. Suitability and Acceptability. You will be asked to respond to a short structured interview about the device. If the device has reached a wearable stage, you will wear it outside the laboratory while engaging in discussion with one of the researchers before completing the interview. The goal is to obtain the opinions of persons with hearing loss about the device itself, and about their willingness to wear it as a hearing aid in their everyday life, if they were to be involved in a research study.
Part 3 is a focus-group session with about 10 hearing-aid users, some of whom will have participated in Parts 1 and 2. Topics will deal with hearing aids in general and about the current version of the experimental device. Discussion will be recorded for later transcription and analysis. The goal is to gain the perspective of hearing-aid users about hearing aids, hearing-aid research, and the acceptability of this experimental device for field research.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Participants will be accompanied by a researcher while wearing the open-source speech processing platform as a hearing aid - adjusted to their needs using a widely accepted Fitting prescription. Using a hand-held controller, they will readjust to their liking as the acoustic conditions change. After returning to the laboratory, they will complete speech perception tests using under their self-selected amplification conditions and respond to a structured interview dealing with perceived performance of the device and its acceptability as a hearing aid during possible field studies.
Time frame: 1 hour after use of device in lab and field
5-point rating scale. 5 = definitely would use. 0 = definitely would not use
Time frame: 1 hour after self-fitting
Real-ear device output level in dB SPL was measured, as a function of frequency after self-fitting under 2 conditions:
These results were compared with prescriptions based on each participants audiogram.
Note: Although dB outputs were measured at several frequencies, only the average of values at 2, 3, and 4 kHz was used, this being the frequency region at which the greatest effects effects of self-adjustment were observed in earlier studies.
Time frame: 1 hour after use of Master Hearing Aid
% Recognition of speech sounds in lists of monosyllabic words after self-fitting of the Master Hearing Aid
Time frame: 1 hour after final self-fitting in the lab
Adjustment time
Time frame: 1 hour after final self-fitting in the lab
Number of adjustment steps the participant took during self adjustment in the laboratory. The available changes were in overall output level (a single button labelled "Loudness"), in low-frequency output alone (a single button labeled "Fullness"), and high-frequency output alone (a single button labeled "Crispness"). Each increase or decrease was in 3 dB steps.
Time frame: 1 hour after final self-fitting in the lab
Ranges of output
Time frame: 1 hour after final self-fitting in the lab
Spectral tilt explored: The difference between self-adjusted outputs at 750 and 1500 Hz, divided by 2, was defined as "spectral tilt" and recorded in dB per octave. Individual values were averaged and a standard deviation clculated.
San Diego State University
Other
Acronym: EOSP
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06424262
Ear Diseases, Hearing Disorders
Sydney, New South Wales, Australia
View Trial DetailsNCT07667140
Ear Diseases, Hearing Disorders
Oldenburg, Germany
View Trial DetailsNCT06176625
Behavior, Behavioral Symptoms
Baltimore, Maryland, United States
View Trial DetailsNCT07091071
Cochlear Hearing Loss, Cochlear Synaptopathy
Antwerp, Belgium
View Trial Details