Dermscan-Pharmascan
Villeurbanne, 69100, France
NCT Number: NCT03842566
This trial is a knowledge study utilizing skin measurement probes that are non-invasive instruments, with negligible risks for the subjects. No product will be studied.
Looking for future studies?
Notify Me18 year–80 year
Female
Observational
Villeurbanne, 69100, France
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 4 Months
Measured using a 5 point photonumeric scale (Allergan Fine Lines scale)
The scale range is 0 to 4, with 0 indicating no fine lines and 4 being the most severe fine lines (greater than 5 superficial lines with crosshatching).
Time frame: 4 Months
Tissue dielectric constant measurement using MoistureMeter D (Delfin Technologies). Tissue dielectric constant is expressed as a unitless value that is directly proportional to the amount of water in the tissue.
Time frame: 4 Months
Tissue dielectric constant measurement using a Corneometer (Courage & Khazaka). Tissue dielectric constant is expressed as a unitless value that is directly proportional to the amount of water in the tissue.
Time frame: 4 Months
Transepidermal water loss measurement using an AquaFlux AF100 (Biox Systems Ltd)
Time frame: 4 Months
Measurement of light reflection using a Skin-Glossymeter GL200 (Courage & Khazaka)
Time frame: 4 Months
Skin colorimetric measurement using a Spectrophotometer (Konica Minolta)
Time frame: 4 Months
Colorimetric measurement of skin melanin using a Mexameter MX18 (Courage & Khazaka)
Time frame: 4 Months
Skin elasticity measurement using a Cutometer (Courage & Khazaka), ElastiMeter (Delfin Technologies), and Dermal Torque Meter (Dia-Stron Limited)
Time frame: 4 Months
Ultrasound imaging using a Dermascan Ultrasound (Cortex Technology)
Time frame: 4 Months
Skin topography imaged using a PRIMOS (Canfield Scientific) fringe projection imaging system. Output measurements from the images will include Ra (average roughness), Rz (average height of roughness), and Rt (maximum height of the roughness profile).
Time frame: 4 Months
Skin topography imaged using a DermaTOP (EOTECH) fringe projection imaging system. Output measurements from the images will include Ra (average roughness), Rz (average height of roughness), and Rt (maximum height of the roughness profile).
Time frame: 4 Months
Ultrasound imaging using a Dermascan Ultrasound (Cortex Technology)
Time frame: 4 Months
The reproducibility and repeatability of the tissue dielectric constant measurement using MoistureMeter D (Delfin Technologies) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the tissue dielectric constant measurement using a Corneometer (Courage & Khazaka) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the Transepidermal water loss measurement using an AquaFlux AF100 (Biox Systems Ltd) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the light reflection using a Skin-Glossymeter GL200 (Courage & Khazaka) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the skin colorimetric measurement using a Spectrophotometer (Konica Minolta) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the colorimetric measurement of skin melanin using a Mexameter MX18 (Courage & Khazaka) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the skin elasticity measurement using a Cutometer (Courage & Khazaka), ElastiMeter (Delfin Technologies), and Dermal Torque Meter (Dia-Stron Limited) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the measurement of ultrasound imaging using a Dermascan Ultrasound (Cortex Technology) will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the skin topographyusing a PRIMOS (Canfield Scientific) fringe projection imaging system will be determined by repeating the measurement three times by two technicians
Time frame: 4 Months
The reproducibility and repeatability of the skin topography will be imaged using a DermaTOP (EOTECH) fringe projection imaging system and will be determined by repeating the measurement three times by two technicians
Allergan
Industry
Evaluation of Age-Related Skin Changes Using Clinical Probe Measurements and Imaging
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04655300
Age-related Skin Changes
Haizhu, Guangzhou, China
View Trial DetailsNCT04552249
Age-related Skin Changes
Villeurbanne, France
View Trial Details