ACUVUE OASYS® 1-Day for Astigmatism - TAM 24
DeviceTEST
NCT Number: NCT04794270
This is a bilateral, dispensing, randomized, controlled, double-masked, 2×2 cross-over study to evaluate the clinical performance of ACUVUE OASYS® 1-Day for Astigmatism contact lenses produced on a recently qualified manufacturing line.
Looking for future studies?
Notify Me18 year–39 year
All sexes
Interventional
Not applicable
Sabal Eye Care, Longwood, Florida, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
The subject must:
Exclusion criteria
The subject must not:
TEST
CONTROL
Time frame: Fitting, 1-Week Follow-up
Overall comfort was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
Time frame: Fitting, 1-Week Follow-up
Overall vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
Time frame: Fitting, 1-Week Follow-up
Overall handling was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
Time frame: 1-Week Follow-up
Visual performance was calculated as monocular contact lens-corrected distance visual acuity using a Logarithm of Minimal Angle of Resolution (logMAR) visual acuity scale. This was evaluated under high luminance and high contrast conditions (HLHC) at 4 meters from Early Treatment Diabetic Retinopathy Study (ETDRS) charts at the 1-week follow-up visit. Lower visual performance values indicate better vision. Two measurements were performed for each eye. The average visual performance was reported for each lens type.
Time frame: Post-Fitting at 1-minute, at 3-minute
Lens rotation was recorded from direction and magnitude in degrees to the nearest degree at one and three minutes following lens insertion during settling period. All lenses in this study have scribe marks at 6 o'clock and 12 o'clock positions and rotation measurements were made relative to a vertical reference line.
Time frame: Fitting, 1-Week Follow-up
Mean settled rotation was calculated from all repeated measures of signed lens orientation upon settling for each subject/eye/lens.
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details