The semiconductor (cadmium-zinc-telluride, CZT) cameras significantly increase detection sensitivity in Single Photon Emission Computer Tomoscintigraphy (SPECT)(1) . The clinical routine applications of these cameras are today mainly limited to myocardial tomoscintigraphy with CZT dedicated cameras. Several studies whose one was done in Hospital of Nancy, made it possible to demonstrate a good diagnosis agreement between conventional cameras and semiconductor cameras in this indication, with better image quality obtained with semiconductor cameras (2). Today, so-called "wide field" semiconductor cameras are available in the clinic and allow for any type of SPECT examination. A comparative study between conventional and semiconductor cameras has been conducted for bone scintigraphy, and shows diagnostic superiority with this new type of camera (3).
In addition, the new VERITON-CT ™ (Spectrum Dynamics Medical) camera has 12 mobile CZT-based detectors positioned around the patient allowing tomographic acquisitions and focusing the acquisition on the organ studied. This camera has a sensitivity of detection higher than that of conventional cameras and thus reduces the activity injected into the patient and / or the recording time.
To date, no study has compared the two types of cameras in nuclear neurology and in particular, for the SPECT DaTSCAN ™ imaging of the pre-synaptic dopaminergic pathway.
DaTSCAN ™ exam is used in clinical routine:
1. for the diagnosis of Parkinson's disease or related diseases when in doubt with an essential tremor (4) or 2. if suspicion of Lewy body disease, if in doubt with Alzheimer's disease (5). If the interpretation of DaTSCAN ™ exam is first visual, the quantification may increase accuracy diagnosis (6). Also, the database creation specific to each type of camera is recommended(7).
The purpose of this study is to compare the diagnostically relevant informations and the quantitative analysis provided by the DaTSCAN™ SPECT, recorded on the conventional camera and recorded on the semiconductor camera VERITON-CT™
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Vandœuvre-lès-Nancy, 54511, France
The clinical study is monocentric, interventional, non randomized, with minimal risk and constraints.
All patients going to the nuclear medicine department for a DaTSCAN exam will be able to participate in this study if they understood study informations given by the physician and if they signed the inform consent.
In first, patients will have a DaTSCAN™ SPECT on a conventional camera and after, they will have DaTSCAN™ SPECT on VERITON-CT™ camera with two records: one in focus striatum mode and the second in focus brain mode.
The attenuation correction will be made with the computer tomography (CT) recorded at the same time as the SPECT (SPECT/CT)
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
the intervention is based on two recordings in camera VERITON-CT ; the first, in focus striatum mode and the second in brain focus mode
Time frame: 16 months
comparison between the exam results (positive diagnosis of Parkinson disease or Lewy bodies dementia versus differential diagnosis) in conventional camera and the one obtained with the VERITON-CT in striatum focus mode
Time frame: 16 months
comparison between the exam results (positive diagnosis of Parkinson disease or Lewy bodies dementia versus differential diagnosis) in conventional camera and the one obtained with the VERITON-CT in brain focus mode
Time frame: 16 months
comparison between the exam results (positive diagnosis of Parkinson disease versus differential diagnosis) in conventional camera and the one obtained with the VERITON-CT in striatum focus mode
Time frame: 16 months after the first enrollment
comparison between the exam results (positive diagnosis of Lewy bodies dementia versus differential diagnosis) in conventional camera and the one obtained with the VERITON-CT in striatum focus mode
Time frame: immediately after SPECT-CT exam
the uptake ratios are:caudate nuclei/occipital cortex, putamen/occipital cortex, to the right and caudate nuclei/medium cingulate cortex, putamen/medium cingulate cortex to left, obtained with conventional camera and on the striatum focus record with VERITON-CT camera
Time frame: immediately after SPECT-CT exam
0= very bad quality and impossible to do a diagnosis, 1=bad quality and difficult diagnosis, 2= medium quality, 3 = good quality and 4= excellent quality
Time frame: immediately after SPECT-CT exams
recorded activities will be reported by injected MBq for the images obtained with the conventional camera and with VERITON striatum focus record
Time frame: 18 months
The agreement will be between conventional record and striatum focus record with VERITON camera
Time frame: after each SPECT/CT exams
the uptake ratios are:caudate nuclei/occipital cortex, putamen/occipital cortex, to the right and caudate nuclei/medium cingulate cortex, putamen/medium cingulate cortex to left, obtained with conventional camera and on the brain focus record with VERITON-CT camera
Time frame: immediately after SPECT-CT exams
0= very bad quality and impossible to do a diagnosis, 1=bad quality and difficult diagnosis, 2= medium quality, 3 = good quality and 4= excellent quality
Time frame: 18 months
recorded activities will be reported by injected MegaBecquerel (MBq) for the images obtained with the conventional camera and with VERITON brain focus record
Time frame: 18 months
The agreement will be between conventional record and brain focus record with VERITON camera
Central Hospital, Nancy, France
Other
Comparative Study of DaTSCAN ™ Cerebral SPECT Recorded by Conventional Anger Cameras and Semiconductor Camera (VERITON-CT ™)
Acronym: VERIDAT
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06133283
Basal Ganglia Diseases, Brain Diseases
San Antonio, Texas, United States
View Trial DetailsNCT05766813
Basal Ganglia Diseases, Brain Diseases
Phoenix, Arizona, United States
View Trial DetailsNCT07723027
Basal Ganglia Diseases, Brain Diseases
Shakargarh, Punjab Province, Pakistan
View Trial DetailsNCT07361250
Basal Ganglia Diseases, Brain Diseases
Wuhan, Hubei, China
View Trial Details