Tufts Medical Center
Boston, Massachusetts, 02111, United States
NCT Number: NCT01825278
This study proposes to evaluate the clinical applicability of the ExSpiron Respiratory Volume Monitor (RVM, ExSpiron™, Respiratory Motion, Inc.; Waltham, MA) in obese surgical patients undergoing general anesthesia. Previous work has demonstrated the ability of the ExSpiron monitor to provide non-invasive, real-time, continuous measurements of respiratory parameters such as tidal volume (TV), minute ventilation (MV) and respiratory rate (RR) mostly in normal weight patients but those studies did not specifically look at obese subjects. Respiratory depression, in the postoperative setting due to residual anesthetics and/or opioid administration, continues to be a significant cause of adverse outcomes. Obese patients are at increased risk for respiratory complications. Currently, there is no objective measure of early respiratory indicators for developing respiratory compromise. Current respiratory assessment in non-intubated patients relies on oximetry data and subjective clinical assessment. Pulse oximetry has been extremely helpful in recognizing oxygen desaturations but it is a late indicator of respiratory decline. There is no current device capable of giving real time ventilatory information such as tidal volume and minute ventilation of a patient that is not mechanically ventilated. The ExSpiron system utilizes an impedance based technology and proprietary algorithms (Respiratory Motion Inc.) to obtain these measurements. The study hypotheses are that the non-invasive, impedance-based RVM monitor will accurately reflect TV, RR and MV in obese surgical patients before induction of general anesthesia, during controlled ventilation and following extubation; that ExSpiron will accurately reflect the post-extubation respiratory status of the patient; and that apnea and hypopnea episodes in the recovery room as detected by the ExSpiron monitor are correlated with the individual risk for obstructive sleep apnea as determined by the STOP-Bang risk stratification.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Boston, Massachusetts, 02111, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Monitoring sensors will be applied to patient's right chest and the monitoring device will collect breathing parameters such as breathing rate and volumes before, during and after the procedure until patient is ready to leave the recovery room. At the beginning and at the end of the study investigator will perform a one-time measurement of patient's respiratory parameters using a standard handheld spirometer. This is a non-invasive device that is commonly used in clinical care not related to research.
Other names: ExSpiron monitor
Time frame: 1 - 1.5 hours before surgery
Patient will have a monitoring strip applied to right chest in the pre op holding area, and respiratory data will be recorded to the monitor. These will be compared with data from a manual handheld spirometer via 5 recordings over a time period of 5 minutes.
Time frame: 1 - 3 hours in the recovery room
Patient will continue to be monitored for MV, TV and RR after surgery in the recovery room, until recovery from anesthesia up to 3 hours. Respiratory data will be recorded to the monitor. These will be compared with data from a manual handheld spirometer via 3 recordings over a time period of 3 minutes. The change in the respiratory values to preoperative baseline will also be compared
Time frame: 1 - 3 hours postoperatively
The pattern of respiration as assessed by the Exspiron monitor continued in the recovery room after surgery will be correlated with the patients OSA risk as determined by the STOP-BANG questionaire
Tufts Medical Center
Other
The Evaluation of a Respiratory Monitor in Surgical Patients With a BMI >35 Undergoing Elective Surgery Under General Anesthesia
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05929079
Apnea, Body Weight
Anniston, Alabama, United States
View Trial DetailsNCT05929066
Apnea, Arthritis
Phoenix, Arizona, United States
View Trial DetailsNCT04793334
Apnea, Body Weight
La Jolla, California, United States
View Trial DetailsNCT05343000
Apnea, Body Weight
Rochester, Minnesota, United States
View Trial Details