Closed-loop system
DeviceClosed-loop system consisting of a terminal including the Diabeloop algorithm that is associated with the Dexcom G6 CGM and the Accu-Chek Insight insulin pump.
NCT Number: NCT05369871
The objective of this clinical trial is to study the feasibility of using a closed loop and its impact on glycemic control, in patients with type 2 diabetes (T2D) treated with insulin pumps.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
CH Métropole Savoie, Chambéry, France
T2D is a condition that combines insulin resistance and relative insulin deficiency. T2D naturally evolves into an increasingly marked insulin deficiency that leads to the need for pancreatic replacement, by administering insulin.
Type 1 diabetes (T1D) requires an integral and immediate substitution of pancreatic insulin secretion. Artificial intelligence, through a self-learning algorithm, enables the automation and personalization of insulin delivery. These devices, called "closed loops" bring a real benefit for the patients included in the studies, by improving the glycemic balance, by reducing the number of hypo- and hyperglycemias but also by reducing the mental load associated with the disease, improving their quality of life.
The objective of this clinical trial is to study the feasibility of using a closed loop and its impact on glycemic control, in patients with T2D treated with insulin pumps.
A 13-week interventional, randomized, controlled, crossover, open-label, multicenter main study, followed by an optional, open-label, additional 4-week study is proposed to patients.
Main objective: study of the impact of the closed loop for 6 weeks, compared to 6 weeks in an open loop, on glycemic balance (evaluated by the time in range 70-180 mg/dL).
Secondary objectives: study of the impact of the closed loop for 6 weeks, compared to 6 weeks in an open loop, on:
Evaluation of the satisfaction of the use (usability) of the system at the end of the closed loop period.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
No Inclusion Criteria:
Closed-loop system consisting of a terminal including the Diabeloop algorithm that is associated with the Dexcom G6 CGM and the Accu-Chek Insight insulin pump.
Open-loop system consisting of a terminal without the Diabeloop algorithm that is associated with the Dexcom G6 CGM and the usual insulin pump.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the glycemic balance (time spent in the target 70-180 mg/dL).
The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the daily glycemic variability measured by the coefficient of variation The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the daily glycemic variability measured by the standard deviation.
The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the percentage of daily time spent in hypoglycemia.
The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the percentage of daily time spent in hyperglycemia.
The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the average daily amount of insulin administered.
The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the Glucose management indicator (GMI) measurement using CGM data.
The data used for the analysis are the last 4 weeks of each 6-week sequence.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the daily physical activity, measured by actimetry for 7 days.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the sleep quality (duration and fragmentation), measured by actimetry for 7 days.
Time frame: Days 42 and 84 (according to the randomized arm)
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the diabetes treatment satisfaction, measured by the Diabetes Treatment Satisfaction Questionnaire (DTSQ).
The DTSQ questionnaire is composed by a score which has a minimum of zero and a maximum of 36. The higher the score, the more satisfied the patient is with their treatment.
Time frame: Days 42 or 84 (according to the randomized arm)
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the quality of life, measured by a questionnaire.
This questionnaire is composed of 10 items. For each item, there are 3 possible answers: "less well than before"; "same as before"; "better than before". A score will be calculated from the 10 items by adding 1 point for each improvement answer allowing the calculation of a score varying between 0 and 10. A high score represents a better improvement in quality of life.
Time frame: Day 84
Impact of 6 weeks of closed-loop compared to 6 weeks of open-loop on the treatment safety, measured by the number of adverse events
Time frame: Days 42 or 84 (according to the randomized arm)
Evaluation of the closed loop system satisfaction by an usability questionnaire
This questionnaire is composed of 5 sections. Section 1 evaluates satisfaction with the use of the medical device and will be evaluated through a score varying between 10 and 50. A high score means that satisfaction with the use of the device is high.
Section 3 evaluates the ease of use of the device and will be evaluated through a score varying between 16 and 80. A high score means that the system is easy to use.
Sections 2, 4 and 5 will not be scored and will only be subject to descriptive analysis.
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the glycemic balance (time spent in the target 70-180 mg/dL).
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the daily glycemic variability measured by the coefficient of variation
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the daily glycemic variability measured by the standard deviation
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the daily time spent in hypoglycemia
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the daily time spent in hyperglycemia
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the average daily amount of insulin administered
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the Glucose management indicator (GMI) measurement using CGM data.
Time frame: Day 112
Impact of 4 weeks of closed-loop without meal declaration compared to 4 weeks of closed-loop with meal declaration on the diabetes treatment satisfaction, measured by the Diabetes Treatment Satisfaction Questionnaire.
The DTSQ questionnaire is composed by a score which has a minimum of zero and a maximum of 36. The higher the score, the more satisfied the patient is with their treatment.
Time frame: Day 112
Evaluation of the system satisfaction by an usability questionnaire
This questionnaire is composed of 5 sections. Section 1 evaluates satisfaction with the use of the medical device and will be evaluated through a score varying between 10 and 50. A high score means that satisfaction with the use of the device is high.
Section 3 evaluates the ease of use of the device and will be evaluated through a score varying between 16 and 80. A high score means that the system is easy to use.
Sections 2, 4 and 5 will not be scored and will only be subject to descriptive analysis.
Diabeloop
Industry
Acronym: Close2target
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.