MVA/HIV62B vaccine
Biological1×10^8 TCID50 dose to be administered as a 1 mL intramuscular (IM) injection in the deltoid
NCT Number: NCT02852005
The purpose of this study is to evaluate the safety, tolerability, and immunogenicity of the AIDSVAX B/E vaccine and the MVA/HIV62B vaccine in healthy, HIV-1-uninfected adults who previously received MVA/HIV62B in DNA/MVA or MVA/MVA vaccine regimens in the HVTN 205 study.
Looking for future studies?
Notify Me18 year–55 year
All sexes
Interventional
Phase 1
ACSA CRS, Iquitos, Maynas, Peru
This study will evaluate the safety, tolerability, and immunogenicity of the AIDSVAX B/E vaccine and the MVA/HIV62B vaccine in healthy, HIV-1-uninfected adults who previously received MVA/HIV62B in DNA/MVA or MVA/MVA vaccine regimens as part of the HVTN 205 study.
Participants in this study will be assigned to one of five groups based on their previous vaccine regimen received in HVTN 205. Depending on their group, participants will receive the MVA/HIV62B vaccine, the AIDSVAX B/E vaccine, or both the MVA/HIV62B vaccine and the AIDSVAX B/E vaccine. All participants will receive their assigned vaccines at study entry (Day 0) and Month 4. Participants will attend several study visits through Month 10. Visits will include physical examinations, blood collection, HIV testing and risk reduction counseling, and interviews and questionnaires. Optional procedures at some visits include collection of rectal fluids, cervical fluids, and semen. Study staff will contact participants 2 years following the initial study injection for follow-up health monitoring.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
General and Demographic Criteria:
HIV-Related Criteria:
Laboratory Inclusion Values:
Hemogram/Complete Blood Count (CBC)
Chemistry
Virology
Urine
Reproductive Status
Exclusion criteria
General
Vaccines and Other Injections
Immune System
Cardiac
Clinically Significant Medical Conditions
1×10^8 TCID50 dose to be administered as a 1 mL intramuscular (IM) injection in the deltoid
600 mcg/mL dose to be administered as a 1 mL IM injection in the deltoid
Sodium Chloride for Injection USP, 0.9% to be administered as a 1 mL IM injection in the deltoid
Time frame: Measured through 3 days after the boost at Month 0 and Month 4
Graded according to the Division of AIDS (DAIDS) Table for Grading the Severity of Adult and Pediatric Adverse Events, Version 2.0 [November 2014], The maximum grade observed for each symptom over the time frame is presented.
Time frame: Measured through 3 days after the boost at Month 0 and Month 4
Graded according to the Division of AIDS (DAIDS) Table for Grading the Severity of Adult and Pediatric Adverse Events, Version 2.0 [November 2014], The maximum grade observed for each symptom over the time frame is presented.
Time frame: Measured through Month Measured through 3 days after each boost at Month 0 and 4
Graded according to the Division of AIDS (DAIDS) Table for Grading the Severity of Adult and Pediatric Adverse Events, Version 2.0 [November 2014], The maximum grade observed for each symptom over the time frame is presented.
Time frame: Measured through Month 10
From the study termination form, early termination reasons associated with an AE or reactogenicity are tabulated by treatment arm
Time frame: Measured through the Month 4 boost
From the study product discontinuation form, study product administration reasons are tabulated by treatment arm
Time frame: Measured during screening, and 2 weeks after each boost at Month 0 and 4
For each chemistry laboratory measure, summary statistics were presented by analyte and treatment group for the overall population.
Time frame: Measured during screening, and 2 weeks after each boost at Month 0 and 4
For each chemistry laboratory measure, summary statistics were presented by analyte and treatment group for the overall population.
Time frame: Measured during screening, and 2 weeks after each boost at Month 0 and 4
For each chemistry laboratory measure, summary statistics were presented by analyte and treatment group for the overall population.
Time frame: Measured at Month 0.5 and 4.5
Serum HIV-1-specific IgG responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. The responses to the IDR of gp41 was not assayed.
Time frame: Measured at Month 0.5 and 4.5
Serum HIV-1-specific IgG responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. The responses to the IDR of gp41 was not assayed.
Time frame: Measured at Month 0.5 and 4.5
Serum HIV-1-specific IgG3 responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. The responses to the IDR of gp41 was not assayed.
Time frame: Measured at Month 0.5 and 4.5
Serum HIV-1-specific IgG3 responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. The responses to the IDR of gp41 was not assayed.
Time frame: Measured at Month 0.5 and 4.5
Serum HIV-1-specific IgA responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. IgA responses to V1V2 and the IDR of gp41 were not assayed.
Time frame: Measured at Month 0.5 and 4.5
Serum HIV-1-specific IgA responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. IgA responses to V1V2 and the IDR of gp41 were not assayed.
Time frame: Measured at Month 0.5 and 4.5
Neutralizing antibodies against HIV-1 were measured as a function of reductions in Tat-regulated luciferase (Luc) reporter gene expression in TZM-bl cells. The assay measured neutralization titers against a panel of autologous and heterologous Env-pseudotyped viruses.
Time frame: Measured at Month 0.5 and 4.5
Neutralizing antibodies against HIV-1 were measured as a function of reductions in Tat-regulated luciferase (Luc) reporter gene expression in TZM-bl cells. The assay measured neutralization titers against a panel of autologous and heterologous Env-pseudotyped viruses. A serum neutralization titer was defined as the serum dilution that reduced relative luminescence units (RLUs) by 50% (ID50) relative to the RLUs in virus control wells (cells + virus only) after subtraction of background RLU (cells only). Titer < 10 is truncated at 5.
Time frame: Measured at Month 4.5
PBMC samples are stimulated with synthetic peptide pools or left unstimulated as a negative control. For each sample, T-cell subset, and peptide pool, response magnitude is % cells expressing markers after peptide stimulation minus % cells expressing markers after no stimulation. Response positivity is derived by testing if the number of cells expressing the marker is equal in the stimulated vs. unstimulated cells. Response is positive if the one-sided Fisher's exact test (discrete Bonferroni adjustment over the peptide pools) p<=0.00001. The Fisher's exact test is not applied to compare between endpoints. Data are excluded if the blood draw date was outside the visit window, the participant was HIV-infected, PBMC viability or T-cell count were low, or negative control was high. The responses at month 0.5 was not assayed.
Time frame: Measured at Month 4.5
PBMC samples are stimulated with synthetic peptide pools or left unstimulated as a negative control. For each sample, T-cell subset, and peptide pool, response magnitude is % cells expressing markers after peptide stimulation minus % cells expressing markers after no stimulation. Response positivity is derived by testing if the number of cells expressing the marker is equal in the stimulated vs. unstimulated cells. Response is positive if the one-sided Fisher's exact test (discrete Bonferroni adjustment over the peptide pools) p<=0.00001. The Fisher's exact test is not applied to compare between endpoints. Data are excluded if the blood draw date was outside the visit window, the participant was HIV-infected, PBMC viability or T-cell count were low, or negative control was high. The responses at month 0.5 was not assayed.
Time frame: Measured at Month 4.5
PBMC samples are stimulated with synthetic peptide pools or left unstimulated as a negative control. For each sample, T-cell subset, and peptide pool, response magnitude is % cells expressing markers after peptide stimulation minus % cells expressing markers after no stimulation. A contingency table is constructed to assess response: stimulation (peptide/none) vs. marker expression (yes/no). A one-sided Fisher's exact test is applied, testing if the number of cells positive for the marker is equal in the stimulated vs. unstimulated cells. A discrete Bonferroni adjustment is made over the peptide pools. Response is positive if p<=0.00001. Data are excluded if the blood draw date was outside the visit window, the participant was HIV-infected, PBMC viability or T-cell count were low, or negative control was high. The responses at month 0.5 was not assayed.
Time frame: Measured at Month 4.5
PBMC samples are stimulated with synthetic peptide pools or left unstimulated as a negative control. For each sample, T-cell subset, and peptide pool, response magnitude is % cells expressing markers after peptide stimulation minus % cells expressing markers after no stimulation. A contingency table is constructed to assess response: stimulation (peptide/none) vs. marker expression (yes/no). A one-sided Fisher's exact test is applied, testing if the number of cells positive for the marker is equal in the stimulated vs. unstimulated cells. A discrete Bonferroni adjustment is made over the peptide pools. Response is positive if p<=0.00001. Data are excluded if the blood draw date was outside the visit window, the participant was HIV-infected, PBMC viability or T-cell count were low, or negative control was high. The responses at month 0.5 was not assayed.
Time frame: Measured at Month 10
Serum HIV-1-specific IgG responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. The responses to the IDR of gp41 was not assayed.
Time frame: Measured at Month 10
Serum HIV-1-specific IgG responses were measured on a Bio-Plex instrument using a standardized custom Luminex assay. The readout is background-subtracted mean fluorescent intensity (MFI), with background adjustment for an antigen-specific plate level control. For each sample, response magnitude is net MFI, defined as experimental antigen MFI minus reference antigen MFI. Net MFI less than 1 is set to 1. The measure unit fluorescence units are relative to assay background, not relative to the placebo arm. Background is used here rather than negative control stimulation, since the antigens are used as bead coating rather than stimulation. The responses to the IDR of gp41 was not assayed.
National Institute of Allergy and Infectious Diseases (NIAID)
Nih
A Phase 1 Clinical Trial to Evaluate the Immunogenicity of AIDSVAX B/E Bivalent gp120 Vaccine and MVA/HIV62B in Healthy, HIV-1-Uninfected Adult Participants Who Previously Received MVA/HIV62B in DNA/MVA or MVA/MVA Regimens in HVTN 205
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04680390
Behavior, Blood-Borne Infections
San Francisco, California, United States
View Trial DetailsNCT03048422
Blood-Borne Infections, Communicable Diseases
Jacksonville, Florida, United States
View Trial DetailsNCT05388474
Blood-Borne Infections, Communicable Diseases
Los Angeles, California, United States
View Trial DetailsNCT03284710
Blood-Borne Infections, Communicable Diseases
Maputo, Mozambique
View Trial Details