NCT Number: NCT02111993
The objective of this study is to evaluate myocardial injury, if any, as quantified by cardiac markers (Troponin-T) in defibrillation threshold (DFT) testing during implantation of implantable cardioverter defibrillators (ICDs) using the upper limit of vulnerability (ULV) method vs. standard defibrillation threshold method.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
La Jolla, California, 92093, United States
This is a prospective, randomized (1:1 DFT vs ULV testing), controlled clinical research trial. Patients undergoing ICD implant or device change out will be candidates for this study. Medical records for these patients will be screened prior to enrollment to ensure eligibility for the study. Each patient who is a candidate and who agrees to participate in the study will undergo the standard of care pre-procedure evaluation including a complete medical history evaluation, a complete physical examination and routine laboratory testing including chemistry panel, hematology panel, coagulation panel, a 12-lead electrocardiogram, and a urine pregnancy test (all females of child-bearing age). A candidate patient will be randomly assigned to either the standard DFT testing method group or the ULV testing method group.
For the standard DFT testing group, per routine standard of care, the patient will be admitted to the hospital. The study requires a pre-procedure blood test of 3 ml for Troponin-T (TnT) which will be drawn prior to any DFT testing. The blood sample will be sent to the University of California, San Diego (UCSD) central laboratory for processing. The patient will then undergo the scheduled ICD implant procedure in a standard fashion. The standard defibrillation threshold testing will be performed using a low energy shock delivered on T-wave to induce ventricular fibrillation (VF). If VF is induced, the first shock is 25 Joules (J). If success, we will wait 5 minutes and repeat the process. If the 2nd shock yields success, the DFT testing is complete and a 10J safety margin achieved (device shock energy is set at 35J or as clinically indicated determined by treating Cardiac Electrophysiologist). A back-up external defibrillator will always be immediately available in case transvenous shocks fail. Blood pressure will be monitored before and immediately after each shock. After 4 hours, 8 hours and 16 hours post DFT testing, blood samples (3 ml for Troponin-T) will be drawn and sent to the UCSD central laboratory for processing.
For the ULV testing group, per routine standard of care, the patient will be admitted to the hospital. The study requires a pre-procedure blood test (3 ml for Troponin-T.) which will be drawn prior to any ULV testing. The blood sample will be sent to the UCSD central laboratory for processing. The patient will then undergo the scheduled ICD implant procedure as is standard clinical care. The ULV testing is performed as follows: for single coil device, a 18J shock will be delivered at 0msec, +20 msec, -20msec and -40msec measured from the peak of the T-wave; for dual coil device, a 18J shock will be delivered at 0msec, -20msec, +20msec, and +40msec measured from the peak of the T-wave. If VF is not induced with any of the above mentioned shocks, the ULV will be considered as 18J and the ICD will be implanted with the first shock strength set at 30 joules or as clinically indicated determined by treating Cardiac Electrophysiologist. If VF is induced, a 25J rescue shock will be delivered as is standard and if successful, the device will be programmed to the maximum output of 35 joules or as clinically indicated determined by treating Cardiac Electrophysiologist. Blood pressure will be monitored before and immediately after each shock. After 4 hours, 8 hours and 16 hours post ULV testing, blood samples (3 ml for Troponin-T) will be drawn and sent to the UCSD central laboratory for processing.
Other than the blood tests for Troponin-T, there is no change in routine post-operative management. Patients will be followed every three months, as is standard management for patients with ICDs.
The TnT blood draws at 4-hour, 8-hour and 16-hour post implantation will not require longer hospital stay than is standard for patients undergoing ICD implantation. The results of Troponin-T measurement for the study patients will be reviewed by the cardiac electrophysiology (EP) research staff. If myocardial injury is noted (any TnT value >0.1 as per current assay at the UCSD laboratory), the patient will be monitored as is deemed clinically necessary by treating Cardiac Electrophysiologist, including possible repeat TnT measurements for evaluation of myocardial infarction. We will follow standard of care for management of myocardial injury as recommended by the American Heart Association and the American College of Cardiology. Elevated TnT measurements may delay hospitalization, if determined to be clinically necessary. If the repeat TnT measurement is <0.1, then myocardial injury is most unlikely and the positive TnT value is likely due to DFT shocks.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Once the ICD is implanted, Standard Defibrillation Threshold (DFT) testing will begin. A low energy shock will be delivered to the heart at the peak of the T wave to induce ventricular fibrillation (VF). Once VF is induced, a rescue shock of 25J will be delivered to restore sinus rhythm. This process will be repeated once more after 5 minutes.
Other names: ICD implantation
Once the ICD is implanted, Upper Limit of Vulnerability (ULV) testing will commence. An 18 J shock will be delivered will at different points from the t-wave. If VF is not induced with any of these shocks, then the ULV will be considered to be 18J. If VF is induced, then a 25 J rescue shock will be delivered.
Other names: ICD implantation
Time frame: 20 hours (hr)
Myocardial damage will be evaluated by cardiac troponin (cTNT) lab collection before and then after ULV or DFT testing at 4 hours, 8 hours, and 20 hours.
Time frame: 20 hours (hr)
the DFT group cardiac troponin (cTNT) values were compared to the subjects within the ULV group that required VF induction.
Time frame: 20 hours (hr)
The DFT group was compared to the ULV subgroup that did not require ventricular fibrillation (VF) induction. Cardiac troponin (cTNT) levels were analyzed.
University of California, San Diego
Other
Evaluating Myocardial Injury During ICD Implantation Using the Upper Limit of Vulnerability (ULV) Method vs. Standard Defibrillation Threshold Testing
Acronym: ULV
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02111980
Arrhythmias, Cardiac, Cardiac Arrhythmia
La Jolla, California, United States
View Trial DetailsNCT02166762
Arrhythmias, Cardiac, Cardiac Arrhythmia
La Jolla, California, United States
View Trial DetailsNCT01648634
Cardiomyopathies, Cardiomyopathy
Paris, France
View Trial DetailsNCT01261065
Cardiomyopathies, Cardiomyopathy
Houston, Texas, United States
View Trial Details