A device has been developed which is placed under the mattress, thereby escaping contact with patient, which enables monitoring of sleep activity and has been shown in some studies to provide an estimate of the frequency of sleep disordered breathing. If the estimates of sleep disordered breathing from this new device are medically equivalent to current excepted home sleep apnea test devices within clinically important ranges of sleep disordered breathing, it may have several benefits. This study is designed to help answer several important clinical questions, namely, is the new device clinically equivalent to an established HSAT device for patients who have at least moderately severe OSA, and what is the effect of multiple nights on classification of severity and presence of OSA.

Completed

Looking for future studies?

Notify Me

Key information

Age range

22 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Mayo Clinic in Rochester

Rochester, Minnesota, 55905, United States

About this study

The design will be a prospective test of two diagnostic testing strategies. The tests will take place in the same patient concurrently, so the patient's results from one test will serve as the comparator with the other test device. No randomization or blinding is needed.

Patients will be recruited from the Mayo Clinic Center for Sleep Medicine (and another sleep center with enriched racial variety). Consecutive patients in whom the clinician has ordered a WatchPAT™ will be potential candidates for an opportunity to participate in the study. Patients will be made aware of the trial by invitation from members of the healthcare team. Interested patients will be evaluated according to the inclusion and exclusion criteria.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Clinician suspects of having OSA due to presence of any:

  • STOP-BANG ≥ 3,
  • overnight oximetry with ODI ≥ 5,
  • STOP-BANG≥ 2 and one or more of: disrupted sleep, cognitive complaints, paroxysmal or prior atrial-fibrillation (now in NSR), stroke, TIA
  • Has a smartphone capable of running both Withings and Itamar's app
  • Stable sleeping quarters and schedule (i.e., no overnight shifts) for at least 7 days
  • Domicile has capable wireless internet service

Exclusion criteria

  • Uses short-acting nitrates within 3 hours of the study
  • Has a permanent pacemaker
  • Atrial fibrillation or sustained supraventricular arrhythmias
  • Known congestive heart failure Class ≥ 1, or known LVEF< 45%
  • Sustained hypoxemia or hypoventilation (results of RA daytime ABG show SaO2<90% or PaCO2>45 mmHg, or overnight oximetry shows mean SaO2<90%.)
  • Advanced pulmonary disease (COPD GOLD stage ≥ II , pulmonary fibrosis with GAP ≥ 1 or significant dyspnea on exertion

Treatment and study plan

Under-mattress sleep monitor

Diagnostic Test

Under-mattress sleep monitor for patients with a confirmed diagnosis of Obstructive Sleep Apnea.

Primary outcomes

  1. The apnea hypopnea index (AHI)

    Time frame: 12 months

    The apnea hypopnea index (AHI) provided by one-night of testing with the WatchPAT™ is equivalent to the AHI provided by the mean of 7 nights use of the Withings™ sleep monitor. The equivalence margin will be an AHI≤5/hr.

Secondary outcomes

  1. Sensitivity

    Time frame: 12 months

    The Withings sleep monitor will have a sensitivity ≥ 0.825 to identify patients with moderate to severe OSA as assessed by a WatchPAT AHI≥15.

Other outcomes

  1. Positive likelihood ratio

    Time frame: 12 months

    The Withings sleep monitor will have a likelihood ratio ≥ 5 to identify patients with moderate to severe OSA as assessed by a WatchPAT AHI≥15

Sponsors and collaborators

Lead sponsor

Mayo Clinic

Other

Collaborators

  • Withings

Registry information

Official study title

Evaluating an Under-mattress Sleep Monitor Compared to a Peripheral Arterial Tonometry Home Sleep Apnea Test Device in the Diagnosis of Obstructive Sleep Apnea

Important dates

Study start
2021
Primary completion
2021
Study completion
2021
First posted
Mar 3, 2021
Registry last updated
May 5, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.