Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07017907

Evaluating an AI Tool for Detecting Thyrotoxic States

This observational study aims to evaluate the performance of a software-based medical device, Glandy HYPER, in detecting the thyrotoxic state in patients with hyperthyroidism. The device utilizes heart rate data collected from commercially available wearable devices and compares it with thyroid function test results. The study will enroll patients diagnosed with Graves' disease, monitoring their heart rate during sleep and correlating these measurements with free T4 levels obtained through serial blood testing. No investigational device output will be disclosed to participants, and the study will not alter standard clinical care.

Recruiting

Interested in participating?

Request Info

Key information

Age range

22 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Umesh Masharani

San Francisco, California, 94143, United States

Location status: Recruiting

Location contact

Umesh Masharani, MD

CONTACT

[email protected]

415-353-2350

About this study

This is a single-center, prospective observational study designed to validate the performance of Glandy HYPER, a software medical device that analyzes sleep heart rate data from wearable devices in conjunction with thyroid function test (TFT) results to detect thyrotoxicosis. The study targets adults aged 22 or older with newly diagnosed or currently treated Graves' disease.

Each participant will wear a smartwatch (Apple or Samsung, depending on their smartphone OS) to measure heart rate during sleep over a 12-week period. Blood samples for TFTs will be collected at four separate visits (baseline and at 4, 8, and 12 weeks). The primary endpoint is the F1 score between the investigational device's output and the diagnosis of thyrotoxicosis based on free T4 values. Secondary endpoints include sensitivity, specificity, and area under the curve (AUC) of the device's performance.

Data from the wearable device and TFTs will be used to create multiple evaluation-reference data pairs per patient, enabling within-subject validation across different time points. The study does not involve any investigational treatment or alteration to standard care and is classified as non-significant risk (NSR). The output of the software device will not influence clinical decisions during the trial.

The study also aims to assess the generalizability of the software's performance by comparing results from this U.S.-based cohort with prior studies conducted in Korea.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adults aged 22 years or older, regardless of sex.
  • Individuals who are newly diagnosed with Graves' disease or currently undergoing treatment for it.
  • Individuals who have received sufficient explanation about the investigational software and are able to use it appropriately.
  • Individuals who voluntarily agree to participate in the study and have signed informed consent, either directly or via a legally authorized representative.

Exclusion criteria

  • Individuals with cardiac conditions such as arrhythmia or heart failure.
  • Individuals taking medications that significantly affect heart rate, including antiarrhythmics or antihistamines. (Intermittent short-acting beta-blockers are allowed.)
  • Pregnant or breastfeeding individuals, or those planning pregnancy during the study period or not using appropriate contraception.
  • Individuals with significant comorbidities that interfere with follow-up or study compliance.
  • Individuals with severe psychiatric disorders, substance use disorder, or alcohol dependence.
  • Individuals deemed ineligible at the discretion of the investigator for safety or ethical concerns.

Treatment and study plan

Heart rate-based AI software for detecting thyrotoxicosis

Device

A software-based investigational medical device that uses artificial intelligence to detect the thyrotoxic state in patients with hyperthyroidism. The device analyzes resting heart rate data collected from wearable devices along with thyroid function test results (free T4 and TSH). The device is not FDA-approved and will be used solely for observational performance evaluation without influencing clinical care.

Primary outcomes

  1. F1 Score for Detection of Thyrotoxicosis Using the Investigational Software

    Time frame: At weeks 4, 8, and 12 after baseline (Visit 2), up to 12 weeks total

    The F1 score will be calculated to evaluate the performance of the AI-based investigational software in detecting thyrotoxic states. The device's output, derived from wearable heart rate data and reference data, will be compared against the diagnosis based on serum free T4 concentration at each time point. Each participant contributes multiple data pairs (evaluation-reference combinations) based on serial visits (V2-V5), and the F1 score will be calculated for each case and summarized across all cases.

Secondary outcomes

  1. Sensitivity and Specificity of the Software in Detecting Thyrotoxicosis

    Time frame: At weeks 4, 8, and 12 after baseline (Visit 2), up to 12 weeks total

    The sensitivity and specificity of the investigational AI software will be calculated by comparing its output to the diagnosis of thyrotoxicosis based on serum free T4 levels. Results will be computed for each evaluation-reference data pair and summarized across all participants, with 95% confidence intervals.

  2. Area Under the Receiver Operating Characteristic Curve (AUC) for Thyrotoxicosis Detection

    Time frame: At weeks 4, 8, and 12 after baseline (Visit 2), up to 12 weeks total

    The AUC will be calculated to assess the diagnostic performance of the investigational software in distinguishing thyrotoxicosis from euthyroid and hypothyroid states, using free T4 levels as the reference. The AUC will be calculated per case and summarized across all evaluable cases.

Study contacts

Contact information is provided by the study sponsor or research team.

Jae Hoon Moon, MD, PhD

CONTACT

[email protected]

+82-10-5105-9815

Jun An

CONTACT

[email protected]

‭+82 10-2849-0041‬

Sponsors and collaborators

Lead sponsor

THYROSCOPE INC.

Industry

Registry information

Official study title

Performance Evaluation of the Software Medical Device to Detect the Thyrotoxic State in Patients With Hyperthyroidism

Important dates

Study start
2026
Primary completion
2026
Study completion
2026
First posted
Jun 12, 2025
Registry last updated
Jun 1, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.