Universitätsspital Basel
Basel, Canton of Basel-City, 4031, Switzerland
NCT Number: NCT05999916
The present study aims to assess the safety and feasibility of repeated transcranial alternating current stimulation (tACS) by the Miamind Neurostimulator in a cohort of healthy participants. Based on the findings of this investigation, subsequent clinical trials assessing the efficiency of tACS by the Miamind Neurostimulator for treatment of Alzheimer's Disease will be conducted.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Basel, Canton of Basel-City, 4031, Switzerland
The pathological hallmarks of Alzheimer's Disease (AD) are extracellular amyloid-β (Aβ) plaques and intracellular neurofibrillary tangles of hyperphosphorylated tau deposition in the brain together with neuroinflammation and microglial activation. These alterations lead to synaptic dysfunction, neuronal loss, and subsequently to brain circuit and brain oscillation disruption, resulting in cognitive decline. Recent studies have shown a positive effect of neural entrainment at gamma frequency (30-80 Hz). Transcranial alternating current stimulation (tACS) utilizes low amplitude alternating currents, allowing for frequency and region-specific brain oscillation entrainment showing positive results regarding improvement of cognitive functions in healthy participants and Alzheimer's Disease patients. Miamind Neurostimulator is a patient specific MRI-based 3D printed medical device that permits electrical stimulation and recording on up to 32 electrode channels and thus allows for simultaneous, multifocal, and targeted brain stimulation. tACS is non- invasive, well tolerated by users and considered safe with no persistent adverse events reported.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
No vulnerable subject is enrolled on this study
60 min. 40 Hz max. 1mA / electrode & total of max. 2 mA across all electrodes. 30- s ramp-up personalised intervention based on individual modelling of electric field distribution to maximise therapeutic effect in the target region. Three target regions, consecutively stimulated (20min each).
Time frame: up to 2 weeks
Safety of the Treatment defined as the proportion of study participants free of serious adverse device effects and unanticipated serious adverse device effects (SADE and USADE) assessed via a safety questionnaire and medical evaluation.
Time frame: up to 2 weeks
Adverse Events and comfort of tACS and the medical device are reported by questionnaires following stimulation of each target region at visit °3 & °4 and following sequential stimulation of multiple target regions at visit °5 & °6.
Time frame: up to 2 weeks
Changes in d2-R attention test are reported to document the functional impact of tACS on concentration and attention before and after stimulation of each target region at visit °3 & °4 and before and after sequential stimulation of multiple target regions at visit °5 & °6.
The d2-R attention test measures processing speed, rule compliance, and quality of performance as estimation of attention and concentration and scores them as the following separate items: speed, concentration, carefulness. Each item is scored from 20-80. A higher score indicates better performance.
Time frame: up to 2 weeks
Quantification of EEG measurements to document the functional impact of tACS on oscillatory activity in individual frequency bands (delta, theta, alpha, beta, gamma) and EEG-biomarkers (alpha peak frequency, Vigilance) before and after stimulation of each target region at visit °3 & °4 & °5 & °6.
Time frame: up to 2 weeks
MoCA scores are documented before and after visit °3 and after visit °6 to evaluate the impact of repeated tACS on cognitive performance.
The MoCA has a total scoring range of 0-30, with the score based on the number of correct answers made in each of the 7 following items: Visuospatial/Executive, Naming, Memory/delayed recall, Attention, Language, Abstraction, Orientation. Sub-scores and total score are reported.
A lower total score indicate greater cognitive impairment.
Time frame: up to 2 weeks
The subjective impression and satisfaction of the participant regarding the device and the intervention is documented using a one-time questionnaire at the end of the study.
Bottneuro AG
Industry
A Prospective, Single-Arm, Monocentric Pilot Study to Evaluate the Safety and Feasibility of Transcranial Alternate Current Stimulation With the Miamind Neurostimulator in Healthy Participants
Acronym: MindStim
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07341568
Cognition Disorders, Cognitive Dysfunction
Riyadh, Saudi Arabia
View Trial DetailsNCT06027320
Alzheimer Disease, Brain Diseases
Bedford, Massachusetts, United States
View Trial DetailsNCT02851173
Cognition Disorders, Cognitive Dysfunction
Austin, Texas, United States
View Trial DetailsNCT07083089
Basal Ganglia Diseases, Brain Diseases
Montpellier, France
View Trial Details