Universite Saint Joseph, Faculte de Medecine
Beirut, 0000, Lebanon
NCT Number: NCT07517601
This randomized split-mouth clinical trial evaluates enamel surface preservation, pulpal temperature variation, and patient-reported discomfort during ceramic orthodontic bracket removal using two Erbium-doped yttrium aluminum garnet (Er:YAG) laser parameter settings compared to conventional mechanical debonding. Pulpal temperature is monitored in real time using a thermocouple device. Enamel integrity is assessed using the Adhesive Remnant Index (ARI) under 40× magnification. The study aims to determine optimal laser parameters ensuring safe and conservative bracket removal.
This study is active but is not currently recruiting participants.
Notify Me20 year–35 year
All sexes
Interventional
Not applicable
Beirut, 0000, Lebanon
Orthodontic bracket debonding must restore enamel close to its pretreatment condition while minimizing iatrogenic damage. Ceramic brackets demonstrate high bond strength and are associated with increased enamel fracture risk during conventional removal. Laser-assisted debonding has been proposed to reduce mechanical stress by softening the adhesive interface. However, concerns remain regarding pulpal temperature elevation and enamel surface alteration.
This randomized split-mouth clinical trial compares two Er:YAG laser parameter settings with conventional plier debonding. Pulpal temperature variation will be measured using a thermocouple inserted into the pulp chamber. Enamel surface evaluation will be performed using 40× magnification to assess ARI score. Pain perception will be recorded using a visual analog scale (VAS). The study aims to optimize laser parameters while ensuring biological safety and enamel preservation.
This split-mouth clinical trial includes 10 patients (100 maxillary teeth, teeth 15-25). Brackets are randomized by quadrant into:
Laser Parameter 1 (Er:YAG, 4 W, 400 mJ, 10 Hz)
Laser Parameter 2 (Er:YAG, 4.5 W, 300 mJ, 15 Hz)
Conventional mechanical debonding
Primary outcome: pulpal temperature variation (∆T). Secondary outcomes: ARI score and pain perception (VAS).
Laser irradiation is performed using LightWalker II ST-E Pro+ (Fotona, 2940 nm), non-contact mode, 45° angle, 1 cm distance, MicroShort pulse (MSP) mode, air=1, water=1, 10-15 seconds scanning.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Er:YAG laser (LightWalker II ST-E Pro+, Fotona, 2940 nm wavelength) applied in non-contact mode at 4 W average power, 400 mJ pulse energy, 10 Hz frequency, MSP mode (100 µs pulse duration), air=1 and water=1 settings. Laser applied at 45° angle, 1 cm distance, scanning method for 10-15 seconds until bracket detachment.
Er:YAG laser (LightWalker II ST-E Pro+, Fotona, 2940 nm wavelength) applied in non-contact mode at 4.5 W average power, 300 mJ pulse energy, 15 Hz frequency, MSP mode (100 µs pulse duration), air=1 and water=1 settings. Laser applied at 45° angle, 1 cm distance, scanning method for 10-15 seconds until bracket detachment.
Ceramic bracket removal using orthodontic debonding pliers (3M™ Unitek™ Debonding Instrument) applying controlled torsional force to bracket wings according to standard clinical protocol.
Time frame: During laser assisted bracket removal procedure
Real-time pulp chamber temperature measured using a calibrated K-type thermocouple during laser irradiation. Temperature change recorded in degrees Celsius (°C).
Time frame: Immediately after bracket removal
Microscopic evaluation at 40× magnification using Artun and Bergland scale (0-3).
Time frame: Immediately after each quadrant debonding
Patient-reported pain measured using a 10 cm Visual Analog Scale (0-10).
Saint-Joseph University
Other
Evaluation of Enamel Surface and Pulpal Temperature for Ceramic Bracket Removal Using Two Laser Intensities Versus Conventional Technique: A Split-Mouth Clinical Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06266130
Orthodontic Brackets
Glendale, California, United States
View Trial DetailsNCT07185087
Behavior, Health Behavior
Baghdad, Iraq
View Trial DetailsNCT05193708
Dental Bonding, Indirect Bonding
Cairo, Egypt
View Trial DetailsNCT06324162
Debonding, Orthodontic Brackets
Krakow, Poland
View Trial Details