University of California, Davis
Sacramento, California, 95187, United States
NCT Number: NCT07705425
To investigate and evaluate the benefits of adding EchoPixel Holographic Therapy Guidance to the current standard of care in Structural Heart (SH) procedures.
Current structural heart (SH) procedures rely on standard image guidance (SIG) relies on 2D X-plane or multiplanar reformatted (MPR) views that can conceal critical anatomy elements at the time of implant or therapy delivery which are crucial to achieve an optimal long term durable outcome.
This limitation complicates an operator's task of optimally implanting a 3D device, delivered by tools that rotate and maneuver in 3D, within a dynamic 3D anatomy, the heart. Slight mismatches between the device and the target in the heart are indicative of a sub-optimal device position, a key risk-factor of peri-device leak (PDL) and other complications.
The primary objective of the study is to determine if including EchoPixel - HTG as an additive visualization procedural tool has a positive impact on optimal procedure outcomes for patients undergoing in Structural Heart (SH) procedures.
Trial opening soon.
Get Notified18 year and older
All sexes
Interventional
Not applicable
Sacramento, California, 95187, United States
A prospective, single-center, clinical chart review.
In this trial, we will determine if the additional use of EchoPixel - HTG demonstrates a reduction in procedure time, decrease use of contrast and radiation, minimize the number of devices trialed during a procedure, determine ideal fluoroscopic viewing angles for device deployment, and optimize implant deployment and seal in in Structural Heart (SH) procedures.
The study team will compile the redacted pre- procedure CT, redacted procedural Trans-Esophageal Echo (TEE) or Intra-Cardiac Echo (ICE), procedural fluoroscopic imaging and the post device implant imaging created for each procedure case. Patient health information will be redacted and provided to physicians for review. Data will be collected on case report forms.
A prospective review will occur of outcomes regarding the Structural Heart (SH) procedure cases and data will be recorded on case report forms to compare to normal historical outcomes.
All available consecutive patients treated with the Watchman FLX device for Left Atrial Appendage Occlusion (LAAO) or MitraClip for Mitral Valve transcatheter edge to edge repair (M-TEER) will be reviewed. The primary endpoint will be to determine if EchoPixel - HTG assists in better guiding the implanter during the procedure.
All patients 18 and older scheduled for LAAO or M-TEER at the study site and whose procedure will use Philips CVx TEE or 3D ICE.
The Primary objective of the study is to determine if adding EchoPixel - HTG has a positive impact on optimal procedure success for patients undergoing an implantation of a Watchman FLX / MitraClip device compared to patients with current SIG. Procedural metrics and any procedural related complications will be recorded as secondary outcomes.
Patient demographics blinded procedural outcomes, pre-hospital discharge and complications will be monitored through and until the patient follow-up visit.
Study Execution.
Collection of data:
Analysis of procedural data:
Informed Consent Process. This is a prospective trial, utilizing redacted personal health information (PHI). Therefore, consent will be obtained.
Privacy, Confidentiality and Data Handling. The investigator will retain all regulatory documents pertaining to this study in compliance with ICH/GCP guidelines. This includes essential study documents and source documentation that support the data collected on the study Subjects. Each subject's study data will be collected and will be securely stored in the coordinating site's office. Subjects will be identified using a subject identification number. Subject information will be anonymized for data analysis.
RISKS to PARTICIPANTS. As a prospective study, all patients will be managed according to the practice's standard-of-care. As a result, there are no additional risks to the patients having their medical charts reviewed for this study. Staff and employees at the study site have extensive HIPAA training and all records will be retained at the institution. Data collection will involve the recording of protected health information; however, this PHI data will remain at the study site and only de-identified data will be shared with Echopixel. The Watchman FLX procedure / MitraClip is an FDA approved procedure.
BENEFITS to PARTICIPANTS. As an FDA approved device and procedure, there is no direct benefit to the patient. However, information gained from the study will contribute to the body of knowledge regarding the treatment of patients needing the LAAO/MitraClip procedure. Additionally, future patients who may want to consider a LAAO/MitraClip procedure will benefit from the collective published literature base of studies, such as this proposed study.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Left Atrial Appendage Occlusion with HTG as an additive visualization tool for procedure guidance.
Other names: Watchman
Mitral Valve Transcatheter Edge to Edge Repair with HTG as an additive visualization tool for procedure guidance.
Other names: MitraClip, M-TEER
Time frame: 45 days post procedure.
For both LAAO and M-TEER procedures an optimal device position will be established in pre-procedure planning. The optimal device position will be evaluated at the time of the procedure and in post-procedure imaging.
Time frame: Perioperative/Periprocedural measurement of procedure length/duration.
Duration of procedure to implant LAAO or TEER device, in minutes.
Time frame: Perioperative/Periprocedural measurement of length/duration of fluoroscopy use.
Duration/length of use of fluoroscopy to implant LAAO or TEER device, in minutes.
Time frame: Perioperative/Periprocedural measurement of total radiation dose for completing procedure/surgery.
Amount of radiation used to implant LAAO or TEER device in mGy.
Time frame: Perioperative/Periprocedural measurement of total radio-opaque contrast used for completing procedure/surgery.
Amount of radio-opaque contrast used to implant LAAO or TEER device, in ml.
Time frame: Perioperative/Periprocedural count of the total number of devices (LAAO or TEER) utilized/required to complete the procedure/surgery.
The total number of devices (LAAO or TEER) utilized/required to complete the procedure.
Time frame: Perioperative/Periprocedural count of the total number of times a device is positioned for final deployment in order to be released from the delivery catheter in order to complete the procedure/surgery/
The total number of times a device is positioned for final deployment in order to be released from the delivery catheter.
Time frame: Perioperative/Periprocedural and throughout 45-day follow-up visit.
Composite of any procedure-related complications for LAAO or M-TEER.
Contact information is provided by the study sponsor or research team.
EchoPixel, Inc.
Industry
EchoPixel Holographic Therapy Guidance (HTG) for Structural Heart Procedures
Acronym: EPX-HTG-2026
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07380932
Arrhythmias, Cardiac, Atrial Fibrillation
Cologne, Germany
View Trial DetailsNCT07737444
Arrhythmias, Cardiac, Atrial Fibrillation
View Trial DetailsNCT07560644
Arrhythmias, Cardiac, Atrial Fibrillation
View Trial DetailsNCT07633509
Arrhythmias, Cardiac, Atrial Fibrillation
Beijing, Beijing Municipality, China
View Trial Details