EpiFaith Resident Learning Curve Trial

This study aims to evaluate the impact of the EpiFaith® syringe on the learning curve of anesthesia residents for the labor epidural technique. Anesthesia residents with prior experience placing < 5 labor epidurals will be enrolled. Their performance of 20 sequential labor epidural placements with either standard technique with a beveled glass syringe or the EpiFaith® syringe will be observed. Successful epidural placement over time with sequential epidural placement attempts will be measured between groups. The primary outcome will be rate of successful epidural placement. Success will be defined as a composite of 4 criteria: maximum 3 attempts for placement; no need to re-site at a different level; no required intervention by the supervising attending anesthesiologist; and adequate analgesia with a visual analog score (VAS) <3 at 30 minutes. We hypothesize that use of the EpiFaith® syringe will enable a faster learning curve for successful epidural placement. A cumulative sum chart (CUSUM) analysis will evaluate whether the EpiFaith® syringe causes deviation from the control learning curve. Secondary outcomes will include rate of inadvertent dural puncture and epidural replacement rate.

Enrolling by Invitation

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Brigham and Women's Hospital

Boston, Massachusetts, 02115, United States

About this study

The lumbar epidural technique for labor analgesia requires technical training and a manual skillset. A prior study evaluating anesthesia resident learning curves for a traditional labor epidural technique demonstrated a steep learning curve for the first 20 epidural placements, followed by a plateau with gradual proficiency maximized after 60 epidural placements (1). A prior study evaluated a spring-loaded epidural syringe among experienced providers (2). However, the impact of a spring-loaded epidural syringe on novice anesthesia resident learning curves is unknown. In addition, the impact of EpiFaith® use at the time of manual skill acquisition on success with subsequent traditional epidural technical skills is unknown.

The EpiFaith® syringe is FDA-cleared and has a spring-loaded piston designed to detect entry into the epidural space upon loss of resistance (LOR) as the epidural needle tip moves from the dense ligamentum flavum to the high-compliance epidural space. Performing the LOR technique using the EpiFaith® syringe, the piston within the syringe moves forward driven by spring force when a drop in pressure is detected. Piston movement within the syringe is visibly detectable with a yellow indicator in the syringe when LOR occurs. In a feasibility study of 40 labor epidural placements, 3 of 4 expert obstetric anesthesiology physicians reported the EpiFaith® syringe to be equal to superior in quality to the standard LOR syringe, with 100% success rate and no inadvertent dural punctures (3).

Evaluating the impact of the EpiFaith® syringe on learning curves of anesthesia residents with minimal prior technical experience will help inform how we approach education regarding the labor epidural technique. Steeper learning curves with faster time to proficiency may benefit both patients and supervising staff, while if no difference is determined, the use of the EpiFaith® syringe can be de-emphasized during the training period.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Anesthesiology residents with fewer than 5 prior epidural placement experiences

Exclusion criteria

  • anesthesiology residents with more than 5 prior epidural placement experiences

Treatment and study plan

EpiFaith epidural syringe

Device

The EpiFaith syringe is an FDA-cleared epidural syringe.

Control (glass) syringe

Device

glass epidural syringe

Primary outcomes

  1. success of labor epidural attempt

    Time frame: time of epidural placement to 30 minutes after dosing of the epidural

    success of labor epidural attempt over time by each resident, with success defined as a composite requiring:

    • Less than 3 attempts for placement
    • No need to re-site the epidural needle
    • No staff intervention
    • NRS 3 or less at 30 minutes post-loading epidural dose

Secondary outcomes

  1. rating of the epidural syringe

    Time frame: from time of placement to immediately following placement

    rating of the epidural syringe loss of resistance technique

  2. Incidence of inadvertent dural puncture

    Time frame: from time of epidural placement for a maximum of 5 days

    incidence of inadvertent dural puncture

  3. incidence of postdural puncture headache

    Time frame: from time of epidural placement up to 5 days

    incidence of postdural puncture headache

  4. Need for epidural catheter replacement during labor

    Time frame: from time of epidural placement through delivery during hospital admission

    need for epidural catheter replacement during labor

Sponsors and collaborators

Lead sponsor

Brigham and Women's Hospital

Other

Registry information

Official study title

Impact of the EpiFaith® Syringe on the Learning Curve of Anesthesia Residents for the Labor Epidural Technique: A Quasi-Experimental Study

Important dates

Study start
2023
Primary completion
2026
Study completion
2026
First posted
Feb 9, 2026
Registry last updated
Feb 9, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.