Maternal and Child Health Hospital of Nanning City
Nanning, Guangxi, 530021, China
NCT Number: NCT02334150
Combined spinal-epidural analgesia (CSEA) is sometimes used for difficult births, but whether it contributes to postpartum pelvic muscle disorder is unclear. This randomized controlled trial examined whether CSEA affects the electrophysiological index of postpartum pelvic floor muscle during labor. The investigators plan to recruit 300 primiparous healthy women.
Looking for future studies?
Notify Me22 year–30 year
Female
Interventional
Phase 2 / Phase 3
Nanning, Guangxi, 530021, China
Labor analgesia can relieve labor pain, reduce stress reactions, and improve blood supply to the fetus, benefiting mother and baby. Though traditional epidural analgesia has been used for more than 40 years, combined spinal-epidural analgesia (CSEA) has become popular because it provides faster-onset pain relief with minimal motor weakness. CSEA may also accelerate cervical dilation.
Despite the popularity of CSEA, whether it is associated with short- or long-term beneficial or adverse effects on mothers remains unclear. One question is whether the procedure affects the risk of female pelvic floor disorder (PFD), in which the pelvic floor muscles are injured. These muscles are responsible for supporting the pelvic organs and for stabilizing them during the rhythmic, strong labor contractions and for the diaphragm to contract enough to generate pressures of up to 19 kPa. Numerous risk factors have been associated with PFD, including obesity, diabetes, older age, connective tissue disorder, neurological disease, pregnancy, vaginal delivery and childbirth. PFD can lead in turn to stress urinary incontinence, overactive bladder, pelvic organ prolapse and fecal incontinence, all of which can strongly reduce women's physical and psychological health.
Pelvic floor function can be analyzed by measuring the strength and degree of fatigue of pelvic floor muscles, as well as the pelvic dynamic pressure. Abnormalities in these indicators appear even before patients complain of the signs and symptoms of PFD, making them a useful early diagnostic index.
In this randomized controlled study, we examined whether CSEA affects postpartum pelvic floor muscle function in primiparous mothers who give birth vaginally, as well as the duration of different stages of labor. Our results should help establish whether the widespread use of CSEA provides benefits to mothers or poses a risk.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Women in the CSEA group received CSEA during labor. An intravenous line was established when the uterine opening measured 1-2 cm. Then sufentanil (5-7 μg) was injected intrathecally. When the visual analogue pain score was 3 or higher, a mixture of ropivocaine (0.143%) and sufentanil (0.3 μg/ml) was continuously infused into the epidural space using an analgesia pump until the cervix was fully dilated. Load capacity was 5 ml. The analgesic plane was controlled under T10.
Other names: Combined spinal-epidural analgesia
Time frame: 6 weeks
The postpartum strength of pelvic floor muscles was measured with subjects in the supine lithotomy position. A vaginal manometric probe with a balloon was sheathed with a condom and placed into the vagina; the top of the device lay at the bottom of the vagina before air inflation. The other side of the probe was connected to the PHENIX muscle stimulator. Muscle strength was assessed using the international muscle strength detection method, which features a strength scale from 0 to 5. The strength score depends on whether vaginal muscle contraction upon stimulation fails to occur (0 points) or lasts 1 second (1 point), 2 seconds (2 points) and so on. If the contraction lasts 5 seconds or more, a strength score of 5 is assigned.
Time frame: 6 weeks
Degree of muscle fatigue was considered normal if 0%, abnormal if <0%.
Time frame: 6 weeks
Pelvic floor dynamic pressure was considered normal when it fell between 80 and 150 cm H2O.
Nanjing Maternity and Child Health Care Hospital
Other
Effects of Combined Spinal-epidural Analgesia During Labor on Postpartum Electrophysiological Function of Maternal Pelvic Floor Muscle: a Randomized Controlled Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05206409
Prolonged Labor
Cairo, Egypt
View Trial DetailsNCT03430362
Prolonged Labor
Cairo, Egypt
View Trial DetailsNCT03509103
Prolonged Labor
View Trial DetailsNCT02318121
Prolonged Labor
View Trial Details