Medtronic Bakken Research Center
Maastricht, 6229 GW, Netherlands
NCT Number: NCT02149654
Purpose To characterize the safety and clinical benefit of the Engager Transcatheter Aortic Valve Implantation System in a real world environment.
Design Prospective non-randomized, non-interventional, multicenter, single-arm, post-market study.
250 Patients will have the Engager bioprosthesis implanted. Patients will be followed at 1 month, 6 months, and 12 months after the procedure. The recruitment period will be approximately 12 months, so the total study duration will be 24 months.
Looking for future studies?
Notify MeAll sexes
Observational
Maastricht, 6229 GW, Netherlands
The study objective is to characterize the safety and clinical benefit of the Engager Transcatheter Aortic Valve Implantation System in a real world setting.
The primary endpoint of this study is all-cause mortality at 30 days or during index hospitalization.
Secondary endpoints of this study are:
Subject population All patients with severe aortic stenosis requiring treatment, who are selected by a heart team to be treated electively with the Engager Transcatheter Aortic Valve Implantation System are eligible to be included in this study.
Treatment The Engager Transcatheter Aortic Bioprosthesis will be implanted using the Engager Transcatheter Delivery System. The bioprosthesis is delivered transapically on a catheter during a beating heart procedure.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Patient can be included if ALL of the following criteria are met:
Exclusion criteria
Patient will not be included if any of the following conditions exist:
The Engager Transcatheter Aortic Valve Implantation System is indicated for use in patients with symptomatic severe aortic valve stenosis requiring aortic valve replacement and are at high or extreme risk for operative mortality or comorbidity judged by the heart team to pose an absolute or relative contraindication for conventional aortic valve replacement. The system is intended for use in patients with a life expectancy of at least one year following TAVI. The intended performance of the system is to provide relief of aortic valve obstruction without inducing significant regurgitation, thereby restoring effective hemodynamic function of the diseased aortic valve. The intended purpose of the system in this clinical study is in line with the intended purpose in the Instructions for Use.
Time frame: 12 months
The study objective is to characterize the safety and clinical benefit of the Engager Transcatheter Aortic Valve Implantation System in a real world setting.
The primary endpoint of this study is all-cause mortality at 30 days or during index hospitalization.
Time frame: 12 Month follow up
Absence of procedural mortality (all-cause mortality at discharge, 30 days or during index hospitalization), AND correct positioning of the Engager bioprosthesis in the proper anatomic location, AND Engager bioprosthesis performing as intended (no prosthesis-patient mismatch and mean aortic valve gradient < 20 mmHg or peak velocity < 3 m/s, AND no moderate or severe regurgitation).
Composite early safety (at 30 days) according to VARC2. All-cause mortality at 6 months and 1 year; Cardiovascular mortality at 30 days, 6 months and 1 year; Incidence of TAVI-related complications at 30 days, 6 months and 1 year
Medtronic Cardiac Rhythm and Heart Failure
Industry
The Engager ALIGN Study. To Characterize the Safety and Clinical Benefit of the Engager Transcatheter Aortic Valve Implantation System in a Real World Environment.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02729519
Aortic Valve Disease, Aortic Valve Stenosis