Endurant Stent Graft System
DeviceAbdominal Aortic Aneurysm Repair
Other names: Endovascular treatment of Abdominal Aortic Aneurysm
NCT Number: NCT00705718
To demonstrate safety and effectiveness of the Endurant Stent Graft in the treatment of Abdominal Aortic or Aorto-Uni-Iliac Aneurysms.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
University of Alabama Hospitals, Birmingham, Alabama, United States
Prospective, two-arm, non-randomized, multicenter clinical study enrolling subjects treated with the bifurcated stent graft in one arm and subjects treated with the AUI in a second arm.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Abdominal Aortic Aneurysm Repair
Other names: Endovascular treatment of Abdominal Aortic Aneurysm
Time frame: 30 days (Safety)
The primary safety endpoint is composite defined as the proportion of subjects free from major adverse events (MAE) within 1 month (day 0 - Day 30)of implant is non-inferior to the proportion of subjects free from MAEs in the Talent Control Group. The endpoint is defined as the proportion of subjects free from occurence of a MAE within 1 month of the implantation of the Endurant Stent Graft. The major adverse events composite endpoint which will be evaluated at 1 month post implant includes the occurrence of any of the following events.
Time frame: 30 days
The primary safety endpoint is composite defined as the proportion of subjects free from major adverse events (MAE) within 1 month (day 0 - Day 30)of implant is non-inferior to the proportion of subjects free from MAEs in the Talent Control Group. The endpoint is defined as the proportion of subjects free from occurence of a MAE within 1 month of the implantation of the Endurant Stent Graft. The major adverse events composite endpoint which will be evaluated at 1 month post implant includes the occurrence of any of the following events.
Time frame: Intra-operatively
Technical success defined as successful delivery and deployment of the stent graft in the planned location and with no unintentional coverage of both the internal iliac arteries or any visceral aortic branches and with removal of the system. Technical success was assessed intra-operatively.
Time frame: 12 months
Treatment success is defined as Technical success and the following:
Time frame: 12 months
The following secondary endpoints were included in the Pivotal trial to evaluate the safety profile of the Endurant Stent Graft System.
Time frame: 12 months
The following secondary endpoints were included in the pivotal trial to evaluate the effectiveness profile of the Endurant Stent Graft System.
Medtronic Cardiovascular
Industry
Endurant Stent Graft System US Clinical Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02345005
Abdominal Aortic Aneurysms, Aneurysm
Brescia, Italy
View Trial DetailsNCT02477111
Abdominal Aortic Aneurysms, Aneurysm
Bordeaux, France
View Trial DetailsNCT03469245
Abdominal Aortic Aneurysms, Aneurysm
Vienna, Austria
View Trial DetailsNCT00695253
Abdominal Aortic Aneurysms, Aneurysm
Torrance, California, United States
View Trial Details