Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06102980

Endoscopic Ultrasound Shear Wave for Liver Fibrosis in MASLD Patients: The RUMIPAMBA Trial

Currently, there is no description of the contribution of the endoscopic ultrasound (EUS)-guided shear wave elastography (SWE) when describing liver fibrosis in patients with screening criteria of metabolic dysfunction-associated steatotic liver disease (MASLD), with absent-to-mild liver fibrosis. Similar research has been published but using vibration-controlled transient elastography (VCTE), recommended mainly due to its lower cost and less invasiveness. However, VCTE is limited to the anatomical proportions of the patient's body, and cannot assess the right hepatic lobe with less reliability, contrary to the EUS-SWE.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year–79 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Instituto Ecuatoriano de Enfermedades Digestivas (IECED) Gastroclinica SA

Guayaquil, Guayas, 090505, Ecuador

Location status: Recruiting

Location contact

Carlos Robles-Medranda, MD FASGE

PRINCIPAL_INVESTIGATOR

Jorge Baquerizo-Burgos, MD

CONTACT

[email protected]

+593 98 962 7111

Miguel Puga-Tejada, MD MSc

CONTACT

[email protected]

+353 87 686 0537

Raquel Del Valle, MD

SUB_INVESTIGATOR

About this study

Metabolic dysfunction-associated steatotic liver disease (MASLD), formerly non-alcoholic fatty liver disease (NAFLD), is an umbrella term which involves simple liver steatosis, metabolic-associated steatohepatitis (MASH) and MASH-related liver cirrhosis. Liver steatosis relies on imaging or biomarkers, but liver biopsy remains the gold standard for its diagnosis and grading. It comprehends intracellular accumulation of triacylglycerol (TAG) as microvascular or macrovascular lipid droplets in at least 5% of hepatocytes. Liver biopsy is invasive, requires a high-quality biopsy sample, can mislead a diagnosis due to sampling bias, depends on pathologist interpretation variability and implies adverse events related to the punction.

There are non-invasive resources useful for the screening and surveillance of liver steatosis and fibrosis. Apart from serum biomarkers, non-invasive technologies designed for this purpose use transabdominal ultrasound (US)-based elastography, namely: US strain, acoustic radiation force impulse (ARFI), point shear wave elastography (pSWE), two-dimension shear wave elastography (2D-SWE) and vibration-controlled transient elastography (VCTE). Although VCTE presents anatomical limitations when used in overweight patients or assessing the right hepatic lobe, it is largely accepted by international guidelines for assessing liver steatosis and fibrosis. Endoscopic ultrasound (EUS)-guided shear wave elastography (SWE) is independent of the anatomical proportions of the patients, and it permits a more reliable right hepatic lobe evaluation. However, it is an invasive and high-cost procedure.

VCTE, US-ARFI and EUS-SWE determine liver fibrosis quantitatively in terms of liver stiffness through kiloPascals. There are four important gaps in the literature: First, the diagnostic accuracy of VCTE for liver steatosis has been profoundly analysed in NAFLD, but in a wide spectrum of liver fibrosis patients, from absent to cirrhosis. These limits finding extrapolations for screening and surveillance. Second, comparisons between VCTE, US-ARFI and EUS-SWE have concentrated on liver fibrosis or cirrhosis, but they have not been compared head-to-head in the context of absent-to-mild liver fibrosis vs controls. Third, there is no determined diagnostic accuracy for EUS-SWE for an early liver fibrosis estimation in MASLD patients. It is useful considering EUS is becoming a more popular procedure. Finally, and to be consequent with the third point, the identification and grading of liver steatosis and fibrosis still need to be described in the nowadays called MASLD patients.

The present study aims to determine the difference in the estimation of liver fibrosis among VCTE, US-ARFI and EUS-SWE in patients with clinical criteria of MASLD screening but absent-to-mild liver fibrosis, according to non-invasive methods.

This study has been called by the authors through the acronym RUMIPAMBA, which means "Role of endoscopic Ultrasound-guided shear wave for MASLD-related liver steatosis and fibrosis Identification in Patients with Absent to Mild Basal fibrosis, based on non-invasive Analytical laboratory tests". In the general culture, Rumipamba is the name of an archaeological prehispanic and preincaic park from Quito, the capital city of Ecuador.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients referred for any kind of endoscopic procedure.
  • Without clinical suspicion of advanced liver fibrosis.
  • Acceptance to participate in the study.

Exclusion criteria

  • History of greater amounts of alcohol per week (140 g/week and 210 g/week for females and males respectively).
  • Significant or advanced fibrosis by Fibrosis-4 Index (FIB4) or the aspartate aminotransferase to platelet ratio index (APRI).
  • Any liver space-occupying lesion in the US.
  • Comorbidities or conditions related to avoidance of interventional procedures, namely: pregnancy or nursing, coagulopathy or any risk of bleeding, Anaesthesiology Society Association classification IV or higher, New York Heart Association functional class III or IV.

Treatment and study plan

Transparietal ultrasound (US)-based shear wave elastography (SWE) attenuation measurement

Device

The operator will be blinded to any clinical record. Before US-SWE, the patient must be fasted for a minimum of 4 hours and must remain alcohol-free for 7 days. Using an Aloka Arietta 850 (Olympus America, PA, USA), each patient must be supine. Upon breath-hold at the end of expiration, ten measurements will be obtained with the probe placed in the area of the right hepatic lobe through an intercostal space.

Other names: US-SWE attenuation

Transparietal ultrasound (US)-based shear wave elastography (SWE) stiffness measurement

Device

The operator will be blinded to any clinical record. Before US-SWE, the patient must be fasted for a minimum of 4 hours and must remain alcohol-free for 7 days. Using an Aloka Arietta 850 (Olympus America, PA, USA), each patient must be supine. Upon breath-hold at the end of expiration, ten measurements will be obtained with the probe placed in the area of the right hepatic lobe through an intercostal space.

Other names: US-SWE stiffness

Vibration-controlled transient elastography (VCTE) attenuation measurement

Device

The operator will be blinded to any clinical record. Before VCTE, the patient must be fasted for a minimum of 4 hours and must remain alcohol-free for 7 days. Using the FibroScan® Compact 530 (Echosens, Paris, France), each patient must be supine with the right arm in abduction and the ipsilateral hand resting under the head. Upon breath-hold at the end of expiration, ten measurements will be obtained with the M-probe placed in the area of the right hepatic lobe through an intercostal space. Transition to an extra large probe will be based on a VCTE automatic probe selection tool prompt.

Other names: VCTE attenuation

Vibration-controlled transient elastography (VCTE) stiffness measurement

Device

The operator will be blinded to any clinical record. Before VCTE, the patient must be fasted for a minimum of 4 hours and must remain alcohol-free for 7 days. Using the FibroScan® Compact 530 (Echosens, Paris, France), each patient must be supine with the right arm in abduction and the ipsilateral hand resting under the head. Upon breath-hold at the end of expiration, ten measurements will be obtained with the M-probe placed in the area of the right hepatic lobe through an intercostal space. Transition to an extra large probe will be based on a VCTE automatic probe selection tool prompt.

Other names: VCTE measurement

Endoscopic ultrasound (EUS)-guided shear wave elastography (SWE) stiffness measurement

Device

EUS-SWE will be performed by an experienced endoscopist, blinded to clinical records. The expert will use the ArrietaTM 850 EUS console (Fujifilm, Tokyo, Japan) using a linear ultrasound video gastroscope EUS-J10 (Pentax Medical, Hoya Corp, Japan). Both lobes will be evaluated. The transducer will be positioned in the gastric window to visualize right liver segment number five and left liver segment two or three. The elastogram region of interest (ROI) will be placed within the liver tissue at a distance ≥10 mm beneath the hepatic capsule in an area free of vessels and artefacts. A 10-mm circular ROI will be placed within the elastogram at a depth of 4-5 cm from the skin, and a minimum of ten successful kilopascal measurements will be obtained.

In the first stage of this research, the EUS-SWE measurement will be limited to the estimation of liver fibrosis only. Currently, available EUS-SWE equipment does not allow the estimation of the attenuation.

Other names: EUS-SWE attenuation

Primary outcomes

  1. Vibration-controlled transient elastography (VCTE) liver steatosis grade

    Time frame: Six months

    Liver steatosis will be defined by elastography using the controlled attenuation parameter (CAP), measured in decibels per meter.

  2. Transparietal ultrasound (US)-based shear wave elastography (SWE) liver steatosis grade

    Time frame: Six months

    Liver steatosis will be defined by elastography using the attenuation coefficient (ATT), measured in decibels per meter. The ATT corresponds to the VCTE CAP measurement.

  3. Endoscopic ultrasound (EUS)-guided shear wave elastography (SWE) liver steatosis grade

    Time frame: Six months

    Liver steatosis per hepatic lobe will be defined by elastography using the attenuation coefficient (ATT) measurement. The ATT corresponds to the VCTE CAP measurement.

  4. Endoscopic ultrasound (EUS)-guided liver biopsy steatosis grade

    Time frame: Six months

    The EUS-guided liver biopsy findings, per hepatic lobe, will be standardised through the steatosis-Activity-Fibrosis (SAF) score. The SAF scores steatosis (0-3), ballooning degeneration (0-2), lobular inflammation (0-2), and fibrosis (0-4). Liver steatosis is present when proper steatosis is present, and when both features of activity (ballooning and lobular inflammation) display at least grade 1.

Secondary outcomes

  1. Vibration-controlled transient elastography (VCTE) liver fibrosis grade

    Time frame: Six months

    Liver steatosis will be defined by elastography using kilopascals.

  2. Transparietal ultrasound (US)-based shear wave elastography (SWE) liver fibrosis grade

    Time frame: Six months

    Liver steatosis will be defined by elastography using kilopascals.

  3. Endoscopic ultrasound (EUS)-guided shear wave elastography (SWE) liver fibrosis grade

    Time frame: Six months

    Liver steatosis per hepatic lobe will be defined by elastography using kilopascals.

  4. Endoscopic ultrasound (EUS)-guided liver biopsy fibrosis grade

    Time frame: Six months

    The EUS-guided liver biopsy findings, per hepatic lobe, will be standardised through the Brunt system.

Study contacts

Contact information is provided by the study sponsor or research team.

Jorge Baquerizo-Burgos, MD

CONTACT

[email protected]

+593 98 962 7111

Miguel Puga-Tejada, MD

CONTACT

[email protected]

+353 87 686 0537

Sponsors and collaborators

Lead sponsor

Instituto Ecuatoriano de Enfermedades Digestivas

Other

Registry information

Official study title

Estimation of Liver Fibrosis in Patients With MASLD Screening Criteria Through Endoscopic Ultrasound-guided Shear Wave vs Transabdominal Ultrasound and Transient Elastography: The RUMIPAMBA Diagnostic Trial

Important dates

Study start
2023
Primary completion
2024
Study completion
2025
First posted
Oct 26, 2023
Registry last updated
Sep 24, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.