Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06292728

ENDOPLY System in Humans: a Pilot Study

Prospective, non-randomized study aimed at defining the initial pattern of gastric plication with the ENDOPLY System, and assess feasibility, ergonomics and safety of the device Prospective, single-centre, open label, consecutive enrolment

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year–60 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Fakultní nemocnice u sv. Anny v Brně, Gastroenterologické a hepatologické oddělení

Brno, 60200, Czechia

Location status: Recruiting

Location contact

Bohuslav Kianička, prof,MD,PhD

SUB_INVESTIGATOR

Evžen Machytka, MD,PhD

CONTACT

[email protected]

Evžen Machytka, MD,PhD

SUB_INVESTIGATOR

Jan Martínek, prof,MD,PhD

CONTACT

[email protected]

Jan Martínek, prof,MD,PhD

PRINCIPAL_INVESTIGATOR

Robert Prosecký, MD,MPH,PhD

SUB_INVESTIGATOR

About this study

This is a clinical trial of the ENDOPLY System medical device. Clinical data of 10 obese patients (obesity grade I and II) will be analysed. The ENDOPLY System medical device will be used to perform endoscopic internal plication of the stomach. This clinical trial may lead to an extension of the portfolio of medical devices used to perform endoscopic internal gastric plication.

Participation in this clinical trial may help individual trial subjects follow a strict diet that may lead to weight loss. Weight reduction may improve the overall health, quality of life and life expectancy of the trial subjects, but this cannot be guaranteed.

In this clinical trial, the gastric volume reduction procedure using the ENDOPLY System is performed under general anaesthesia. Under general anaesthesia, the ENDOPLY Platform is inserted through the mouth into the oesophagus and upper stomach, after a preliminary endoscopy for standard evaluation. The 5 mm endoscope allows to choose the initial site of the plications, most likely and according to similar techniques at the incisura (junction between the fundus and the antrum). 10 to 15 ligatures will be placed in the upward directions, thereby narrowing the gastric lumen. The investigator will determine during the procedure if the experimented device suits the regular pattern of plication that have been tested over the years in the literature concerning gastric plication.

Gastric volume reduction procedures using the ENDOPLY System may be associated with risks. There is a possibility of rare or unknown side effects. Risks associated with the investigational device (ENDOPLY System) - expected gastric fold fibrosis without adverse local inflammatory reaction. Patients will be administered standard medications as part of the "Standard of Care" endoscopic gastric examination under general anaesthesia.

Subjects participating in this clinical trial will attend regular follow-up appointments at 1, 3, 6, and 12 months after endoscopic internal plication of the stomach as specified in the study protocol.

ENDOPLY System technical information:

The ENDOPLY medical device does not contain as an integral part a medicinal substance or a derivative of human blood or plasma. The ENDOPLY medical device is not manufactured using tissues of animal origin, in order to minimise the risk of transmission of Transmissible Spongiform Encephalopathy to human. The ENDOPLY medical device complies with the essential the requirements laid down for medical devices in conformity assessment under other legislation governing technical requirements for products, with the exception of those aspects which are the subject of clinical trial. Precautions have been taken to protect health and safety with regard to those aspects of the user and the patients. The ENDOPLY medical device does not have a European Union Certificate for now.

Preliminary tests have included preliminary design-freeze and proof of concept, in-vivo studies at the Veterinary school of Lyon in 3 pigs, with an autopsy at three months and pathology samples analysis that have shown the expected fibrosis of gastric folds without adverse local inflammatory reaction.

ENDOPLY System is made by the company ENDOPLY (Lyon, France). The ENDOPLY System has the same goal as the other devices achieving an internal gastric plication, means APOLLO System (means Apollo Endoscopic surgery), ENDOMINA (means comprised of a triangulation platform and an instrument for tissue piercing and approximation) and Medical's Incisionless Operating Platform-primary obesity surgery endoluminal procedure). The ENDOPLY System aims at narrowing the gastric lumen by the mean of separated folds of the internal gastric wall.

The ENDOPLY Platform - Like its competitors, it is an endoscopic tissue approximation device, with the following parts:

  • Handle: it is comprised of two parts that are when the jaws need to be closed.
  • The system is made of several channels are put together and assembled within a shaft:
  • A 5.6 mm channel for the endoscope (paediatric naso-fibroscope), for the time being.
  • A 3 mm channel for the endoscopic grasper.
  • A 5 mm channel for the ligature holder.
  • The ligature: it consists in a 7 cm plastic barbed special tie made in Polyetheretherketone (PEEK), with a self-adjusting mechanism (locker) and fits into a ligature-holder.
  • As a secondary step, a box containing reloads will be installed, thus avoiding frequent in-and-out manipulations. The reload will be also automatized, but those upgrades will not be available for the trial.
  • The extremity of the platform, including delivery catheters outside of the inner perimeter (that is out of the patient's mouth), has been designed to be ergonomic.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • BMI 30-40, i.e. class I and II obese patients
  • Age above 18 and below 60 years
  • Having failed multiples diet attempts

Exclusion criteria

  • Achalasia and other oesophageal motility disorders
  • Severe esophagitis
  • Gastroduodenal ulcer
  • Heart disease and hypertension without treatment
  • Pulmonary, renal or hepatic failure, cancer
  • Pregnancy ongoing, scheduled or in the past months
  • Previous bariatric surgery or endoscopic bariatric technique
  • Participation to another study

Treatment and study plan

ENDOPLY System

Device

One endoscopic procedure where the ENDOPLY System is used for endoscopic gastric plication.

Primary outcomes

  1. Time of duration of the ENDOPLY System study procedure

    Time frame: Day 1 - Study Procedure

    Median range of duration of the ENDOPLY System study procedure (hours).

  2. Number of ligatures placed by ENDOPLY System study procedure

    Time frame: Day 1 - Study Procedure

    Mean number of ligatures placed by ENDOPLY System study procedure (mean absolute value)

  3. Gastric perforation events

    Time frame: 12 months

    Number of adverse events related to gastric perforation events (absolute value)

  4. Gastrointestinal bleeding events

    Time frame: 12 months

    Number of adverse event related to gastrointestinal bleeding events (absolute value)

  5. Initial weight-loss

    Time frame: 12 months

    Mean weight loss at timepoints: initial assessment and at 1, 3, 6, 12 months (absolute value of mean weight reduction)

Study contacts

Contact information is provided by the study sponsor or research team.

Jerome Dargent, MD

CONTACT

[email protected]

0033681472286

Jitka Macháčková, M.Sc.

CONTACT

[email protected]

Sponsors and collaborators

Lead sponsor

ENDOPLY

Other

Collaborators

  • Just 4 Device s.r.o.

Registry information

Official study title

Safety and Feasibility of the ENDOPLY System in Humans: a Pilot Study

Important dates

Study start
2022
Primary completion
2025
Study completion
2025
First posted
Mar 5, 2024
Registry last updated
Feb 25, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.