Electronic Six-Image Pulse Diagnosis for TCM Syndrome Identification in Sleep Disorders

This is a prospective, single-center, observational diagnostic accuracy study designed to evaluate whether three-dimensional electronic pulse diagnosis can support traditional Chinese medicine syndrome identification in patients with sleep disorders. Participants underwent standardized symptom assessment, expert traditional Chinese medicine syndrome differentiation, and bilateral cun, guan, and chi pulse signal acquisition using the KY-M-A1 electronic pulse diagnostic system. Six-position pulse parameters were used to construct a Six-Image pulse vector, which was compared with a symptom-based Six-Image vector. The main purpose of the study is to assess the concordance between electronic pulse-derived features and expert-determined traditional Chinese medicine syndromes.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–75 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Integrated Traditional Chinese and Western Medicine Hospital of Southern Medical University

Guangzhou, Guangdon, 510000, China

About this study

This study was conducted at the Integrated Traditional Chinese and Western Medicine Hospital of Southern Medical University. It was designed as a prospective, single-center, observational diagnostic accuracy study to explore the relationship between objective pulse diagnostic parameters and traditional Chinese medicine syndrome differentiation in patients with sleep disorders.

Eligible participants were adult patients with sleep disorders who were able to complete pulse examination and questionnaire assessment and who provided written informed consent. Patients with acute disease, severe organic cardiovascular disease, anatomical abnormalities of the radial artery, pregnancy, or other conditions unsuitable for pulse signal acquisition were excluded.

Each participant completed a standardized Six-Image Symptom Questionnaire developed according to the traditional Chinese medicine zang-fu image framework. The questionnaire covered six functional image domains, including heart, liver, spleen, lung, kidney, and San Jiao or mingmen-related domains. Expert traditional Chinese medicine syndrome differentiation was independently performed by two senior traditional Chinese medicine physicians. If disagreement occurred, a third senior expert adjudicated the final predominant syndrome, which served as the reference standard.

Pulse signals were acquired using the KY-M-A1 three-dimensional electronic pulse diagnostic system. Bilateral pulse signals were collected from the cun, guan, and chi positions, yielding six pulse sites in total. Participants rested quietly before acquisition, and pulse signals were recorded under standardized conditions. The system extracted pulse waveform parameters, including pulse amplitude-related indices, to construct a Six-Image pulse vector.

The primary analysis evaluates pulse-syndrome concordance by comparing the Six-Image pulse vector with the symptom-based Six-Image vector using cosine similarity. Higher similarity values indicate stronger agreement between pulse-derived features and symptom-based syndrome domains. Expert-determined traditional Chinese medicine syndrome classification is used as the reference standard. Secondary analyses include the diagnostic consistency between instrument-based syndrome differentiation and expert assessment, as well as receiver operating characteristic curve analysis to evaluate the discriminatory performance of the electronic pulse diagnostic system.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age between 18 and 75 years, regardless of sex.
  • Confirmed diagnosis of sleep disorder with relatively stable symptoms.
  • Ability to complete electronic pulse examination and questionnaire assessment.
  • Provision of written informed consent.

Exclusion criteria

  • Acute phase of disease.
  • Severe organic cardiovascular disease, such as severe arrhythmia or heart failure.
  • Anatomical abnormalities of the radial artery or difficulty in pulse signal acquisition.
  • Pregnancy.
  • Other conditions considered unsuitable for pulse data acquisition by the investigators.

Treatment and study plan

Three-Dimensional Electronic Pulse Diagnosis

Diagnostic Test

All participants underwent bilateral cun, guan, and chi pulse signal acquisition using the KY-M-A1 three-dimensional electronic pulse diagnostic system. The diagnostic test was used to obtain six-position pulse parameters and construct a Six-Image pulse vector for comparison with symptom-based Six-Image vectors and expert traditional Chinese medicine syndrome classification. No treatment intervention was assigned in this observational diagnostic accuracy study.

Other names: KY-M-A1, Electronic Pulse Diagnostic System, Six-Image Pulse Diagnosis

Expert Traditional Chinese Medicine Syndrome Differentiation

Diagnostic Test

All participants underwent expert traditional Chinese medicine syndrome differentiation based on symptom profiles, tongue assessment, pulse palpation, and clinical evaluation. Syndrome differentiation was independently performed by two senior traditional Chinese medicine physicians. In cases of disagreement, a third senior expert adjudicated the final predominant syndrome. The expert-determined syndrome classification served as the reference standard for evaluating the diagnostic performance of the electronic pulse diagnostic system.

Other names: Expert TCM Syndrome Assessment, Reference Standard Syndrome Differentiation

Primary outcomes

  1. Pulse Amplitude Index at the Six Pulse Positions

    Time frame: At the baseline study assessment visit

    The Pulse Amplitude Index was derived from pulse signals acquired by the KY-M-A1 three-dimensional electronic pulse diagnostic system at the bilateral cun, guan, and chi positions. Pulse Amplitude Index values from the six pulse positions were used to objectively characterize pulse wave amplitude distribution and construct the Six-Image pulse vector.

  2. Pulse-Syndrome Concordance Assessed by Cosine Similarity

    Time frame: At the baseline study assessment visit

    Pulse-syndrome concordance was quantified using cosine similarity between the Six-Image pulse vector derived from electronic pulse diagnostic parameters and the Six-Image symptom vector derived from structured traditional Chinese medicine symptom assessment. The similarity score ranges from 0 to 1, with higher values indicating greater concordance between pulse-derived features and symptom-based syndrome domains.

  3. Diagnostic Consistency Between Electronic Pulse Diagnosis and Expert TCM Syndrome Differentiation

    Time frame: At the baseline study assessment visit

    Diagnostic consistency was evaluated by comparing instrument-based syndrome differentiation with expert-determined traditional Chinese medicine syndrome classification. Expert syndrome differentiation served as the reference standard. Consistency was assessed using sensitivity, specificity, and overall accuracy.

Secondary outcomes

  1. Area Under the Receiver Operating Characteristic Curve for Electronic Pulse Diagnosis

    Time frame: At the baseline study assessment visit

    Receiver operating characteristic curve analysis was performed to evaluate the discriminatory performance of pulse-syndrome concordance and instrument-based syndrome classification. The area under the curve was calculated to quantify overall diagnostic discrimination.

  2. Six-Image Pulse Distribution Patterns

    Time frame: At the baseline study assessment visit

    Six-Image radar plots and distribution heat maps were used to visualize Pulse Amplitude Index patterns across the six pulse positions and to characterize pulse distribution patterns corresponding to different traditional Chinese medicine syndrome domains.

  3. Case-Based Six-Position Pulse Map Characteristics

    Time frame: At the baseline study assessment visit

    Representative case-level Six-Image pulse maps were generated using Pulse Amplitude Index values from the six pulse positions to illustrate the individualized application of electronic pulse diagnosis in traditional Chinese medicine syndrome differentiation.

Sponsors and collaborators

Lead sponsor

Southern Medical University Hospital of Integrated Traditional Chinese and Western Medicine

Other Gov

Registry information

Official study title

From Experience to Evidence: Large-Sample Quantitative Modeling of the Six-Image Pulse Framework Using a Modern Pulse Diagnostic Device and Its Performance in TCM Syndrome Identification

Acronym: SIP-TCM

Important dates

Study start
2025
Primary completion
2025
Study completion
2025
First posted
Jul 10, 2026
Registry last updated
Jul 10, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.