Cairo University
Giza, Egypt
NCT Number: NCT06649188
In this study 80 patients will be randomly assigned into two equal groups (40 patients for each group):
1. Group A: Experimental: Magnesium Sulphate Iontophoresis for Postburn Hypertrophic Scar The study group includes 40 postburn hypertrophic scar patients will receive Magnesium Sulphate iontophoresis twice a week for 4 weeks; in addition to their traditional physical therapy program (deep friction massage, stretching and pressure therapy). 2. Group B: Control: Traditional physical therapy for postburn hypertrophic scar This group includes 40 patients with postburn hypertrophic scar who will receive only the traditional PT (deep friction massage, stretching and pressure therapy) 2 sessions per week for 4 weeks
Trial opening soon.
Get Notified20 year–40 year
All sexes
Interventional
Not applicable
Giza, Egypt
High frequency ultrasound is the most common used technique for scar assessment. Its inferior resolution compared to optical equivalents is mitigated by its superior penetration depth allowing thickness analysis, even in severe scar thickening. The working mechanism is based on refection of sound waves of structures with different acoustic impedances and the analysis of the refection time to determine the depth of the structure. The penetration depth ranges from the upper dermal layers to full-thickness skin and subcutaneous structures, depending on the employed frequency (Elrefaie et al., 2020).
The scar will be rated numerically on a ten-step scale by both the patient and doctor on six items: vascularity, pigmentation, thickness, relief, pliability, and surface area on the Observer Scale. The Patient Scale consists of pain, itchiness, color, stiffness, thickness, and irregularity of the scar. Minimal score means good progression and maximum score means the scare is worse (Lenzi et al., 2019).
Iontophoretic drug delivery system (phoresors II auto model PM850 IOMED) The phoresors II auto model PM850 IOMED allows the user to deliver a specific dose from 0 to 80 mA/min, control the current from 0 to 4 mA and automatically calculates required time for the selected dose. Current ramp-up and down, shut-off, error messages and safety checks are also performed automatically. The builtin option for manual current shut-off is an added safety feature (Teslim et al., 2013).
Before each treatment, the surface area of the scar will be cleaned with cotton wool and alcohol to reduce skin resistance. 2.5 ML MgSO4 will be applied to the active positive electrode via a syringe with concentration 100 mg/cm2 (it's available in hospitals and not found in pharmacies), active electrode will be placed directly over the hypertrophic scar. The dispersive electrode will be applied to the skin 6 inch distal from the active electrode (Evans et al., 2001).
The dose needed will be selected in the device which is 75 mA/min (Teslim et al., 2013) then the current will be increased gradually depending on subject tolerance, ranging from 2 to 4 mA, the device will automatically calculate the required time for the selected dose. The interventions will be repeated twice a week for 4 weeks (Teslim et al., 2013). If a subject reports any sensation other than tingling, the treatment will be stopped, the electrodes will be removed and the skin will be inspected (Evans et al., 2001).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
8-Recent MgSO4 administration 6 months before the study. 9-Any subject complaining of psychiatric disorders or neurological disorders such as myasthenia gravis
Iontophoretic drug delivery system (phoresors II auto model PM850 IOMED) The phoresors II auto model PM850 IOMED allows the user to deliver a specific dose from 0 to 80 mA/min, control the current from 0 to 4 mA and automatically calculates required time for the selected dose. Current ramp-up and down, shut-off, error messages and safety checks are also performed automatically. The builtin option for manual current shut-off is an added safety feature (Teslim et al., 2013).
Deep friction massage, stretching and pressure therapy.
Time frame: 4 weeks
High frequency ultrasound is the most common used technique for scar assessment. Its inferior resolution compared to optical equivalents is mitigated by its superior penetration depth allowing thickness analysis, even in severe scar thickening. The working mechanism is based on refection of sound waves of structures with different acoustic impedances and the analysis of the refection time to determine the depth of the structure. The penetration depth ranges from the upper dermal layers to full-thickness skin and subcutaneous structures, depending on the employed frequency (Elrefaie et al., 2020).
Time frame: 4 weeks
The scar will be rated numerically on a ten-step scale by both the patient and doctor on six items: vascularity, pigmentation, thickness, relief, pliability, and surface area on the Observer Scale. The Patient Scale consists of pain, itchiness, color, stiffness, thickness, and irregularity of the scar. Minimal score means good progression and maximum score means the scare is worse (Lenzi et al., 2019).
Contact information is provided by the study sponsor or research team.
Cairo University
Other
Electromotive Drug Administration of Magnesium Sulphate on Hypertrophic Scar Post-Burn
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.