Graduate Institute of Sports Science, National Taiwan Sport University
Taoyuan, 33301, Taiwan
NCT Number: NCT06036953
In recent years, electrical muscle stimulation (EMS) devices have been developed as a complementary training technique that is novel, attractive, and time-saving for physical fitness and rehabilitation. While it is known that EMS training can improve muscle mass and strength, most studies have focused on the elderly or specific patient populations. The aim of this study was to investigate the effects of frequency-specific EMS combined with resistance exercise training for 8 weeks on muscle mass, strength, power, body composition, and parameters related to exercise fatigue. Additionally, we aimed to evaluate the feasibility and safety of EMS as an exercise aid to improve body composition. We recruited 14 male and 14 female subjects who were randomly assigned to two groups with gender parity (7 male and 7 female/group): (1) no EMS group and (2) daily EMS group. Blood biochemical routine analysis was performed every 4 weeks from pre-intervention to post-intervention, and body composition, muscle strength, and explosive power were evaluated 8 weeks before and after the intervention. We also performed an exercise challenge analysis of fatigue biochemical indicators after 8 weeks of intervention.
Looking for future studies?
Notify Me20 year–40 year
All sexes
Interventional
Not applicable
Taoyuan, 33301, Taiwan
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The electric muscle stimulator (EMS) used in this study was from Funcare (Funcare Co., Ltd, Taichung, Taiwan). EMS electrodes were attached to the biceps of both hands, the abdomen, and the quadriceps of both legs sequentially. Each part was stimulated once a day for 30 minutes.
Time frame: After 8 weeks of EMS
To evaluate the maximum oxygen consumption and exercise performance, we used a treadmill (Pulsar, h/p/cosmos, Nussdorf-Traunstein, Germany) and an automatic breathing analyzer (Vmax 29c, Sensor Medics, Yorba Linda, CA, USA). In addition, a polar heart rate device was used to monitor the heart rate (HR). The speed range of the treadmill was set to 7.2 km/h and increased by 1.8 km/h every 2 min until fatigue, according to Bruce's protocol. When the breathing exchange rate (the volume ratio of carbon dioxide produced to oxygen consumed, VCO2/VO2) was higher than 1.10 and reached the maximum heart rate (maximum heart rate = 220 - age), oxygen consumption was considered to be maximum. The three highest VO2max peak were averaged to obtain the VO2max values of the individual volunteers.
Time frame: up to 8 weeks
The multi-frequency principle was applied to measure body composition by using a bioelectrical impedance analyzer (BIA) on an InBody 570 device (In-body, Seoul, South Korea). To perform the measurements, after the subjects' palms and soles were removed from the sensors, the subjects stood on the footing electrodes and held the sensing handles with two hands. During the measurements, the subjects kept their arms open and left their bodies at an angle of 30° without speaking or moving. The subjects also fasted for at least 8 h before the test. The body fat were meansure
Time frame: up to 8 weeks
The multi-frequency principle was applied to measure body composition by using a bioelectrical impedance analyzer (BIA) on an InBody 570 device (In-body, Seoul, South Korea). To perform the measurements, after the subjects' palms and soles were removed from the sensors, the subjects stood on the footing electrodes and held the sensing handles with two hands. During the measurements, the subjects kept their arms open and left their bodies at an angle of 30° without speaking or moving. The subjects also fasted for at least 8 h before the test. The muscle mass were meansure
Time frame: up to 8 weeks
Use the armed grip machine (T.K.K.5401, Takei Scientific Instruments Co.,Ltd, Niigata, Japan) to measure, hold each of the left and right hands three times until they are weak, and record the maximum value
Time frame: up to 8 weeks
The CMJ test is a practical, effective, reliable, and simple method of measuring lower limb strength, which is related to the maximum speed, strength and explosive force of the lower limbs. For this test, participants stood on the Kistler force measurement platform (9260AA, Kistler Co., Ltd., Switzerland) on both feet and performed to inspection. During the test, they were asked to put their hands on their hips and remain on the platform. After that, they were asked to squat down until the knees bent 90 degrees and then to immediately jump as high as possible. The average power (MF), were recorded during the jump. Each participant repeated the test 3 times, and CMJ data were obtained at the designated points. The instrument was calibrated for each individual's weight.
Time frame: After 8 weeks of EMS
For assessment of fatigue-related indices, volunteers fasted for at least 8 h before the 60% VO2max fixed intensity exercise challenge. Blood samples were collected with an arm venous catheter at indicated time points during exercise and recovery periods, including baseline (0), 30 (E30) min during the exercise phase, and 60 (R60) min in the recovery phase. Serum lactate (mmol/L), were assessed for monitoring physiological adaptation. All biochemical indices were assessed using an autoanalyzer (Hitachi 7060, Tokyo, Japan).
Time frame: After 8 weeks of EMS
For assessment of fatigue-related indices, volunteers fasted for at least 8 h before the 60% VO2max fixed intensity exercise challenge. Blood samples were collected with an arm venous catheter at indicated time points during exercise and recovery periods, including baseline (0), 30 (E30) min during the exercise phase, and 60 (R60) min in the recovery phase. Serum ammonia (umol/L), were assessed for monitoring physiological adaptation. All biochemical indices were assessed using an autoanalyzer (Hitachi 7060, Tokyo, Japan).
Time frame: After 8 weeks of EMS
For assessment of fatigue-related indices, volunteers fasted for at least 8 h before the 60% VO2max fixed intensity exercise challenge. Blood samples were collected with an arm venous catheter at indicated time points during exercise and recovery periods, including baseline (0), 30 (E30) min during the exercise phase, and 60 (R60) min in the recovery phase. Serum glucose (mg/dL), were assessed for monitoring physiological adaptation. All biochemical indices were assessed using an autoanalyzer (Hitachi 7060, Tokyo, Japan).
Time frame: baseline, 4 week and 8 week
Safety is assessed function of liver such as AST (8-38 IU/L).
Time frame: baseline, 4 week and 8 week
Safety is assessed function of liver such as ALT (4-44 IU/L).
Time frame: baseline, 4 week and 8 week
Safety is assessed function of kidney such as Bun (6-20 mg/dl)
Time frame: baseline, 4 week and 8 week
Safety is assessed function of kidney such as Creatinine (0.6-1.3 mg/dl)
Time frame: baseline, 4 week and 8 week
Safety is assessed function of kidney such as Uric Acid (3.4-7.6 mg/dl)
Time frame: baseline, 4 week and 8 week
Safety is assessed function of kidney such as total protein (6.4-8.9 g/dl)
Time frame: baseline, 4 week and 8 week
Safety is assessed function of lipid metabolism such as free fatty acid (0.1-0.9 mmol/L)
National Taiwan Sport University
Other
Effect of 8-week Frequency-specific Electrical Muscle Stimulation Combined With Resistance Exercise Training on Muscle Mass, Strength, and Body Composition in Men and Women: A Feasibility and Safety Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05482750
Behavior, Exercise
Porto Alegre, Rio Grande do Sul, Brazil
View Trial DetailsNCT05052164
Behavior, Body Composition
Alicante, San Vicente Del Raspeig, Spain
View Trial DetailsNCT04908150
Behavior, Exercise
Málaga, Spain
View Trial DetailsNCT04321772
Behavior, Exercise
Padova, Italy
View Trial Details