Completed

NCT Number: NCT00417378

Efficacy Study of LV Assist Device to Treat Patients With Cardiogenic Shock (ISAR-SHOCK)

The purpose of this study is to evaluate the efficacy and safety of a left ventricular assist device in comparison to a standard treatment with an intraaortic balloon pump (IABP) in patients with cardiogenic shock due to left ventricular failure following an acute coronary syndrome (myocardial infarction).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

1. Medizinische Klinik, Klinikum rechts der Isar, Munich, Germany

Loading trial locations.

About this study

Cardiogenic shock due to a left ventricular failure after myocardial infarction (MI) is associated with a mortality rate of 50-70 % despite all efforts such as immediate PCI of the occluded vessel, positive inotropic drugs, and the use of intraaortic balloon counterpulsation (IABP). While urgent heart transplantation or the surgical implantation of high-volume left ventricular assist devices are possible treatment options, a widespread use of these techniques for this common complication of myocardial infarction is limited. Because of the easy, percutaneous use of an intraaortic balloon pump, IABP is the method of choice for mechanical assistance in these patients. Despite a lack of randomized data, the ACC/AHA guidelines recommend the use of an intraaortic balloon counterpulsation (Level of evidence IB) in patients with a cardiogenic shock after myocardial infarction. However, improvement of the hemodynamic state by the use of an IABP is limited and the lack of an active cardiac support remains the major limitation of this treatment. Percutaneous left ventricular assist devices may both overcome the limitation of a surgical approach and offer the potential benefit of an active cardiac support during recovery of the failing left ventricle after PCI.

Previous studies have demonstrated a significant improvement of hemodynamic parameters by the use of a catheter-based miniaturized rotary blood pump (Impella LP2.5, Abiomed-Impella CardioSystems GmbH, Aachen, Germany), that is placed retrogradely through the aortic valve. The microaxial pump aspirates blood from the left ventricle and expels it to the ascending aorta with a maximal flow of 2.5 L/min. Randomized data comparing the LVAD with IABP are missing. Therefore, this trial will primarily compare the hemodynamic improvement of the LVAD (Impella LP2.5) with the hemodynamic improvement of an intraaortic balloon counterpulsation (IABP), while secondarily feasibility, safety and mortality will be compared.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Acute coronary syndrome (ACS/AMI) < 48h and cardiogenic shock defined as:
  • Clinical criteria: Hypotension (syst.BP < 90 mmHg and HR > 90/min or an AV- Block II-III) or the need for positive inotropic drugs to maintain BB > 90mm Hg)and end-organ hypoperfusion
  • Hemodynamic criteria: CI < 2.2 L/min/qm and a PCWP > 15 mmHg or an EF of LV < 30% and LVEDP > 20 mmHg.
  • Written informed consent of the patient or his/hers relatives

Exclusion criteria

  • Age < 18 years
  • Prolonged Resuscitation (> 30min)
  • Hypertrophic Obstructive Cardiomyopathy
  • Thrombus in left ventricle
  • Treatment with IABP
  • Severe valvular disease or mechanical heart valve
  • Cardiogenic Shock due to mechanical complications of myocardial infarction such as VSD, acute mitral regurgitation >II°, rupture of the ventricle
  • Failure of the right ventricle defined as the need for a RV Assist Device
  • Septic condition
  • Cerebral Disease
  • Bleeding with a need for surgical intervention
  • Pulmonary embolism
  • Allergy to Heparin or any known coagulopathy
  • Aortic regurgitation >II°
  • Pregnancy
  • Inclusion in another study or trial

Treatment and study plan

Left Ventricular Assist Device Impella LP 2.5

Device

Left Ventricular Assist Device

Intraaortic balloon pump

Device

Counterpulsation

Primary outcomes

  1. Cardiac index

    Time frame: within 1 hour after device implantation

Secondary outcomes

  1. Hemodynamic and metabolic parameters

    Time frame: until to hospital discharge

  2. Mortality

    Time frame: within 30 and 180 days

  3. device-related complications:hemolysis and major bleedings

    Time frame: during hospitalization

Sponsors and collaborators

Lead sponsor

Deutsches Herzzentrum Muenchen

Other

Collaborators

  • Abiomed Inc.

Registry information

Official study title

Left Ventricular Assist Device (Impella LP 2.5) vs. Intraaortic Balloon Counterpulsation (IABP) in Patients With Cardiogenic Shock and Acute Coronary Syndromes

Important dates

Study start
2004
Study completion
2006
First posted
Jan 1, 2007
Registry last updated
Nov 28, 2007

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.