Gadobutrol (Gadavist, Gadovist, BAY86-4875)
Drug1,0M, intra venous injection at a dose of 0,1 ml/kg BW (= 0,1 mmol Gd/kg BW)
NCT Number: NCT00395460
The purpose of this study is to determine if the contrast agent is effective and safe in the Magnetic Resonance Imaging (MRI) of brain or spine diseases in patients of Chinese origin.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Phase 3
Jiangsu Province Hospital, Nanjing, Jiangsu, China
The study has previously been posted by Schering AG, Germany. Schering AG, Germany has been renamed to Bayer HealthCare AG, Germany. Bayer HealthCare AG, Germany is the sponsor of the trial.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
1,0M, intra venous injection at a dose of 0,1 ml/kg BW (= 0,1 mmol Gd/kg BW)
0,5M, intra venous injection at a dose of 0,2 ml/kg BW (= 0,1 mmol Gd/kg BW)
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
CNR = (signal intensity [SI] lesion - SI normal tissue) / standard deviation (SD) background. SI lesion is the signal intensity in the lesion, SI normal tissue is the signal intensity in the normal tissue, and SD background is the standard deviation of the background noise. The signal intensity (SI) on the pre-contrast and on the post-contrast MR scans was to be measured in the enhanced lesion, normal tissue and background.
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
The number of lesions in the magnetic resonance scans was recorded before and after injection of contrast agent for the investigators and all 3 blinded readers (reader 2, reader 3 and reader 4).
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
The change in diagnostic confidence was assessed based on post-contrast compared to pre-contrast scans as "improved", "unchanged" or "worsened" for the investigators and all 3 blinded readers (reader 2, reader 3 and reader 4).
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
The degree of contrast enhancement was recorded on a 4-point scale as follows: 1 = No: lesion is not enhanced. 2 = Moderate: lesion is weakly enhanced. 3 = Good: lesion is clearly enhanced. 4 = Excellent: lesion is clearly and brightly enhanced. In case of more than one lesion, the lesion with maximum enhancement was to be assessed. The change in lesion contrast enhancement was assessed based on post-contrast in comparison to pre-contrast scans for the investigators and all 3 blinded readers (reader 2, reader 3 and reader 4).
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
Lesion delineation was recorded on a 4-point scale as follows: 1 = None: no or unclear delineation of the boundary between lesion and surrounding tissue; 2 = Moderate: some aspects of border delineation covered; 3 = Good: almost clear delineation, but not complete on relevant slices; 4 = Excellent: sharp and complete delineation. In case of more than one lesion, the lesion with maximum enhancement was assessed. Change in lesion delineation was assessed based on post-contrast in comparison to pre-contrast scans for investigators and all 3 blinded readers (reader 2, reader 3 and reader 4).
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
CNR = (SI lesion - SI normal tissue) / SD background. SI lesion is the signal intensity in the lesion, SI normal tissue is the signal intensity in the normal tissue, and SD background is the standard deviation of the background noise. The signal intensity (SI) on the pre-contrast and on the post-contrast MR scans was to be measured in the enhanced lesion, normal tissue and background.
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
CNR = (SI lesion - SI normal tissue) / SD background. SI lesion is the signal intensity in the lesion, SI normal tissue is the signal intensity in the normal tissue, and SD background is the standard deviation of the background noise. The signal intensity (SI) on the pre-contrast and on the post-contrast MR scans was to be measured in the enhanced lesion, normal tissue and background.
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
Investigators and blinded readers (reader 2, 3 and 4) were to record the number of lesions in the magnetic resonance scans before and after injection of contrast agent.
Time frame: Immediately before injection (pre-contrast) and 2-5 min after injection (post-contrast)
Investigators and blinded readers (reader 2, 3 and 4= were to record the number of lesions in the magnetic resonance scans before and after injection of contrast agent.
Bayer
Industry
A Single-blind, Multicenter, Randomized, Phase III Study of the Efficacy and Safety of Gadavist (1.0 M) in Comparison With Magnevist (0.5 M) as Contrast Agent for Enhanced Magnetic Resonance Imaging (MRI) of Central Nervous System (CNS) Lesions in Chinese Patients
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06835634
Bone Diseases, Central Nervous System Diseases
Roma, Italy
View Trial DetailsNCT05318976
Alzheimer Disease, Brain Diseases
Darlinghurst, New South Wales, Australia
View Trial DetailsNCT06249776
Brain Diseases, Brain Infarction
Ahmedabad, Gujarat, India
View Trial DetailsNCT05963828
Brain Diseases, Cardiovascular Diseases
Shanghai, Shanghai Municipality, China
View Trial Details