Skip to main content
OpenTrials
Completed

NCT Number: NCT06261788

Efficacy and Safety of the Sync-AV II Temporary Cardiac Pacing Catheter

This is a prospective, single-center, non-randomized open label study. The objective of this study is to evaluate the efficacy and safety of the Sync-AV II Temporary Cardiac Pacing Catheter in subjects whose elective surgical or interventional procedure require temporary pacing support.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Centro de Intervenciones Endovasculares y Cirugia Cardiovascular

Asunción, Paraguay

About this study

The study will enroll up to 31 subjects at one investigational site with at least 3 implanters.

The subjects enrolled will be followed 7 days after the Sync-AV II Temporary Cardiac Pacing Catheter is removed. A safety call or clinic visit at 7 days post discharge will be performed.

Only subjects who meet the inclusion/exclusion criteria and provide informed consent will be eligible to receive the treatment and participate in the study. potential subjects who have a surgical or interventional procedure that will require temporary cardiac pacing support for at least 24 hours per investigator's medical judgement.

The elective surgical or interventional procedure is to be performed per institutional standard of care. Other concomitant therapy (medication and non-medication therapies) may be used during the study for the treatment or prevention of disease or to maintain good health.

Study Procedure standard of care technique to access the right jugular vein. Thru an introducer the Sync-AV II Temporary Cardiac Pacing Catheter is inserted Confirm and document the leads location as a baseline reference.

Acute Pacing Evaluation Acute pacing threshold evaluation will be performed immediate after leads deployed and at the end of the concomitant procedure.

Pacing Support During Concomitant Procedure Pacing setting to support for subject's medical need during concomitant procedure is per investigator's discretion.

Pacing Support During Hospital Stay Pacing setting to support for subject's medical need during hospital stay is per investigator's discretion.

Pacing Evaluation prior to Lead Removal Pacing lead evaluation will be performed immediately prior to the pacing catheter removal. The evaluation protocol will be the same as the lead evaluation at 24 hours post implant.

End of Study Subjects will exit the study after 7 days follow-up post procedure.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subject is undergoing a surgical or an interventional procedure requiring temporary cardiac pacing to support for at least 24 hours per investigator's medical judgement.
  • Subject is at least 18 years of age.
  • Subject or legal representative provides written informed consent to the study.

Exclusion criteria

  • Subject has a co-exist temporary pacing or an implanted active permanent pacemaker or a cardiac defibrillator.
  • Subject on cardiogenic shock.
  • Subject is currently in atrial fibrillation.
  • Subject is pregnant or breastfeeding.
  • Subject had a stroke within 6 months prior to enrollment.
  • Subject has renal insufficiency with creatinine >2 mg/dl.
  • Subject with known bleeding diathesis.
  • Subject with a history of deep vein thrombosis or pulmonary embolization within 6 months.
  • Subject with known tricuspid valve disease that may impede catheter advance to and withdrawn from right ventricle.
  • Subject with known intracardiac thrombus or vegetation on echocardiography
  • Subject with significant neck abnormalities such that placement of a right and/or left internal jugular vein line would be difficult.
  • Subject has an active systemic infection or local infection at or around the insertion site.
  • Subject is involved in another clinical study that could influence the safety or outcome measures of this study.

Treatment and study plan

Temporary pacing

Device

Transvenous temporary cardiac pacing - right internal jugular insertion

Primary outcomes

  1. With a commercially available pacing box and/or analyzer, measure the ventricular pacing threshold at 24 hours post implant of the investigational device (index procedure)

    Time frame: 24 hours post implant

    Number of participants with a mean ventricular pacing threshold of less than 2.1 volts, measured at 24 hours post index procedure.

  2. Procedure related complications

    Time frame: through study completion, an average of 7 days

    Incidence of serious procedural related complications

    The procedure-related serious complication is defined as:

    • Device-related endocarditis
    • Clinically significant cardiac perforation
    • New pericardial effusions requiring intervention
    • Sustained ventricular or atrial arrhythmia
    • Cardiac tamponade
    • Bleeding requiring transfusion

Sponsors and collaborators

Lead sponsor

Swift Sync, Inc.

Industry

Collaborators

  • Regulatory and Quality Solutions

Registry information

Official study title

Efficacy and Safety of the Sync-AV II Temporary Cardiac Pacing Catheter (EASY II Trial)

Important dates

Study start
2023
Primary completion
2023
Study completion
2023
First posted
Feb 15, 2024
Registry last updated
Feb 15, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.