Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT06075368

Efficacy and Safety of GENOSS® SES in Patients With Acute Coronary Syndrome (GENOSS ACS)

The objective of this study is to evaluate the efficacy and safety of the GENOSS SES in patients with acute coronary syndrome (ACS) in real-world pratice.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

19 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Seoul National University Bundang Hospital

Seongnam-si, Gyeonggi-do, 13620, South Korea

About this study

The Genoss SES is a novel, biodegradable, polymer-coated, sirolimus eluting stent with a cobalt-chromium stent platform and thin strut. Although the efficacy and safety of this stent have been previously investigated, real-world clinical outcomes data are lacking. Therefore, the objective of this prospective, multicenter study was to evaluate the clinical efficacy and safety of the Genoss SES in acute coronary syndrome (ACS) patients undergoing percutaneous coronary intervention.

The Genoss SES study is a prospective, single-arm, observational study for evaluation of clinical outcomes after Genoss SES implantation in ACS patients undergoing percutaneous coronary intervention from 10 sites in South Korea. The primary endpoint was a device-oriented composite endpoint (DOCE), defined as a composite of cardiac death, target vessel-related myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 10 months.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

<Inclusion Criteria>

  • Patients of 19 and over
  • Patients with acute coronary syndrome treated with GENOSS SES
  • Participants who voluntarily decide to participate in this clinical trial, agree to the study protocol and clinical follow-up plan, and provide written informed consent as study participants.

<Exclusion Criteria>

  • Patients who are contraindicated in the use of heparin, aspirin, clopidogrel, sirolimus, cobalt chromium and contrast agents
  • However, patients with hypersensitivity to contrast agents may be eligible if it can be controlled by steroids and pheniramine. Patients with known anaphylaxis are excluded
  • Patients who are pregnant or planning to become pregnant
  • Patients scheduled to undergo surgery requiring the discontinuation of antiplatelet agents within 12 months from registration.
  • Patients with a life expectancy of less than 1 year
  • Patients who presented with cardiogenic shock at admission and are predicted to have a low chance of survival based on medical judgment.
  • Patients who have already received treatment with another DES (Drug Eluting Stent), BVS (Bioresorbable Vascular Scaffolds), or BMS (Bare Metal Stent) at the time of registration.
  • Patients currently participating in a randomized controlled trial involving medical devices.

Treatment and study plan

GENOSS Sirolimus Eluting Coronary Stent System

Device

The GENOSS SES is a novel, biodegradable, polymer-coated, sirolimus-eluting stent with a cobalt chromium stent platform and thin strut.

Primary outcomes

  1. Device-oriented composite endpoint

    Time frame: 12 months after the procedure

    DOCE is defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI) and clinically indicated target-lesion revascularization (TLR).

Secondary outcomes

  1. Target lesion failure (TLF)

    Time frame: 3 years after the procedure

    Target lesion failure (TLF) is defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI) and clinically indicated target-lesion revascularization (TLR).

  2. Target vessel failure (TVF)

    Time frame: 3 years after the procedure

    Target vessel failure (TVF) is defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI) and clinically indicated target-vessel revascularization (TVR).

  3. All-cause death

    Time frame: 3 years after the procedure

  4. Cardiac death

    Time frame: 3 years after the procedure

  5. All-cause death and any myocardial infarction

    Time frame: 3 years after the procedure

  6. Cardiac death and target vessel-related myocardial infarction

    Time frame: 3 years after the procedure

  7. Target vessel revascularization (TVR)

    Time frame: 3 years after the procedure

  8. Target lesion revascularization (TLR)

    Time frame: 3 years after the procedure

  9. Stent thrombosis

    Time frame: 3 years after the procedure

Other outcomes

  1. Safety evaluation

    Time frame: 1 month, 12 months, 2 years, 3 years after the procedure

    Occurrence of stent-related events (cardiac death, myocardial infarction, stent thrombosis, bleeding, etc.) and any damage or complications that are believed to be related to the procedure.

Sponsors and collaborators

Lead sponsor

Genoss Co., Ltd.

Industry

Registry information

Official study title

A Prospective, Multicenter, Observational Study to Evaluate the Efficacy and Safety of GENOSS SES in Patients With Acute Coronary Syndrome

Acronym: GENOSS ACS

Important dates

Study start
2020
Primary completion
2025
Study completion
2027
First posted
Oct 10, 2023
Registry last updated
Feb 11, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.