Seoul National University Bundang Hospital
Seongnam-si, Gyeonggi-do, 13620, South Korea
NCT Number: NCT07590843
The aim of this study is to evaluate the efficacy and safety of mid- and lower-face lifting and contouring treatments using the novel monopolar radiofrequency device, NeoSculpt.
Looking for future studies?
Notify MeAll sexes
Observational
Seongnam-si, Gyeonggi-do, 13620, South Korea
Aging of the face progresses through complex structural changes, including a decrease in skin elasticity, collagen loss, changes in subcutaneous fat distribution, and relaxation of the superficial musculoaponeurotic system (SMAS). These changes are particularly prominent in the mid and lower face, which has led to the widespread use of non-invasive energy-based lifting and contouring procedures in cosmetic and dermatology clinical practices.
Traditional laser and high-output radiofrequency (RF) based lifting treatments generally deliver brief high-temperature energy (over 70°C) to tissues, inducing protein denaturation and coagulation, followed by collagen remodeling through the wound healing process to achieve long-term effects. Although these treatments can induce relatively rapid clinical changes, side effects such as pain during the procedure, as well as erythema, edema, and blisters, which are associated with thermal damage, have been reported.
To address these limitations, there has been increasing interest in low-temperature-maintaining RF treatments that minimize tissue degeneration while inducing biological responses. In particular, RF stimulation in the range of 43-45°C is known to be a temperature range that does not induce tissue coagulation and is believed to trigger reactions related to cellular metabolic activation and programmed cell death (apoptosis), rather than necrosis-based damage with accompanying acute inflammatory responses. This approach has advantages, including relatively less pain, shorter recovery times, and the possibility of repeated treatments.
Recent studies have also reported that TRPV1 receptors, activated by thermal stimulation above 43°C, may be associated not only with pain transmission but also with the activation of fibroblasts, regulation of collagen and extracellular matrix (ECM) synthesis, and regulation of adipocyte metabolism. Some experimental studies have observed an increase in fibroblast proliferation and ECM production when RF energy was applied to maintain a temperature range of 43-45°C for a certain period. However, this evidence has been largely limited to studies focusing on the skin layer, and there is still limited systematic human research on the clinical efficacy and safety of RF treatments that simultaneously stimulate both the skin and subcutaneous fat layers.
NeoSculpt is a monopolar RF system designed with a multi-channel handpiece structure using different frequencies (1 MHz and 2 MHz) to deliver energy progressively to the dermal-SMAS interface and subcutaneous fat layers. Through a low-temperature-maintaining RF protocol, it is expected to achieve mid- and lower-face lifting and contouring effects. However, objective data regarding the efficacy, safety, and clinical changes associated with the use of this device in actual clinical settings are not yet sufficiently accumulated.
This study aims to evaluate the clinical outcomes of mid- and lower-face lifting and contouring treatments using the NeoSculpt monopolar RF device through a retrospective pre-post comparative analysis utilizing existing clinical records.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
This is a retrospective observational study analyzing existing medical records of patients who received NeoSculpt monopolar radiofrequency treatment as part of routine clinical care at a private dermatology clinic. The investigator did not assign or administer any intervention as part of this study. All clinical photographs, 3D photographic assessments, and ultrasound measurements were obtained during routine clinical visits prior to study initiation.
Time frame: baseline, 1month, 2month, 3month, 6month
Two blinded dermatologists independently evaluate standardized clinical photographs taken before and after treatment. Improvement is rated on a 5-point scale (0 = no improvement, 1 = minimal improvement [1-25%], 2 = moderate improvement [26-50%], 3 = marked improvement [51-75%], 4 = excellent improvement [>75%]). Higher scores indicate greater improvement.
Time frame: Baseline, Month 1, Month 2, Month 3, Month 6
Facial volume in the mid-cheek, jawline, and nasolabial fold regions is measured using a 3D photographic system. Change from baseline is reported in cubic millimeters (mm³).
Time frame: Baseline, Month 1, Month 2, Month 3, Month 6
Collagen thickness of the dermal layer is measured using high-frequency ultrasound imaging. Change from baseline is reported in millimeters (mm).
Time frame: Baseline, Month 1, Month 2, Month 3, Month 6
Thickness of adipose tissue adjacent to the superficial musculoaponeurotic system (SMAS) is measured using high-frequency ultrasound imaging. Change from baseline is reported in millimeters (mm).
Time frame: Baseline, Month 1, Month 2, Month 3, Month 6
Three independent, blinded dermatologists evaluate overall facial improvement using the Investigator Global Assessment (IGA) scale. Scores range from 0 to 4 (0 = no improvement, 1 = minimal improvement [1-25%], 2 = moderate improvement [26-50%], 3 = marked improvement [51-75%], 4 = excellent improvement [>75%]). Higher scores indicate greater improvement. The mean score across three evaluators is reported.
Time frame: baseline, 1month, 2month, 3month, 6month
Time frame: Month 1, Month 2, Month 3, Month 6
Description: For participants who experience adverse events, the duration (in days) from onset to resolution is recorded. Clinical course and any management performed are documented at each follow-up visit.
Unit of Measure: Days
Time frame: Month 1, Month 2, Month 3
Patients rate procedural pain using a numeric rating scale from 0 to 10 (0 = no pain, 10 = worst imaginable pain). Higher scores indicate greater pain intensity.
Time frame: Month 1, Month 2, Month 3, Month 6
Patients rate overall satisfaction with treatment outcome using a numeric rating scale from 0 to 10 (0 = completely dissatisfied, 10 = completely satisfied). Higher scores indicate greater satisfaction.
Seoul National University Bundang Hospital
Other
Efficacy and Safety of a Novel Monopolar Radiofrequency Device for Mid and Lower Face Rejuvenation: A Retrospective Pre-Post Comparative Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05694286
Dermal Filler, Rejuvenation
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT02910492
Rejuvenation
Brisbane, California, United States
View Trial DetailsNCT05840445
Disease Attributes, Face
Mexico City, Mexico
View Trial DetailsNCT04640207
Rejuvenation
Plymouth Meeting, Pennsylvania, United States
View Trial Details