Lane Fox Unit, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust
London, SE1 7EH, United Kingdom
NCT Number: NCT06884228
Assessment of the effects of vibrating mesh nebulisation versus jet nebulisation on the electrical activity of the muscles involved in breathing (neural respiratory drive), breathing mechanics (respiratory impedance measured by forced oscillation technique), respiratory flow, heart rate and rhythm, spirometry and breathlessness symptoms in patients with chronic obstructive pulmonary disease who require non-invasive ventilation.
This study is active but is not currently recruiting participants.
18 year–80 year
All sexes
Interventional
Not applicable
London, SE1 7EH, United Kingdom
Background Chronic obstructive pulmonary disease (COPD) remains a leading cause of morbidity and mortality in the United Kingdom. Acute exacerbations of COPD (AECOPD) frequently necessitate hospitalisation, with standard treatment comprising nebulised bronchodilators, antibiotics, and systemic corticosteroids. Approximately 20% of patients hospitalised with AECOPD require non-invasive ventilation (NIV) to manage decompensated hypercapnic respiratory failure, often necessitating concurrent administration of nebulised therapy.
Home NIV use is increasing among COPD patients to improve respiratory symptoms, quality of life, reduce hospitalisation frequency, and enhance survival. These patients may also require nebulised bronchodilator therapy during NIV, particularly when managing acute exacerbations not severe enough to warrant hospitalisation.
Currently, two nebulisation modalities are used as standard of care for patients on NIV:
Jet nebulisation (JN) - the conventional delivery method Vibrating mesh nebulisation (VMN) - a newer technology that utilises a mesh membrane oscillating at high frequency to produce drug-carrying droplets of predetermined size
VMN has been developed to optimise drug delivery in various patient populations, including those who are spontaneously breathing, receiving invasive mechanical ventilation, or on NIV. This technology is designed to enhance pulmonary drug deposition while minimising residual drug volume post-nebulisation.
Previous research has demonstrated that VMN achieves superior pulmonary drug deposition during NIV compared to JN in both healthy subjects and stable COPD patients. VMN has also been shown to produce greater improvements in forced expiratory volume in one second (FEV₁) among hospitalised patients. However, the comparative effects of these nebulisation methods on physiological parameters such as neural respiratory drive and respiratory system impedance during NIV in COPD patients with chronic respiratory failure remain unexplored.
Study Objective This pilot randomised crossover trial aims to compare the physiological effects of vibrating mesh versus jet nebulisation of salbutamol during NIV in patients with chronic respiratory failure due to COPD.
Methods Study Design A randomised crossover trial with participants receiving both interventions with a 48-hour washout period between treatments.
Participants We will recruit 12 patients with COPD currently receiving NIV under the care of the Lane Fox Unit. All participants will provide written informed consent prior to study procedures.
Procedures
Following consent, we will record baseline data including:
NIV settings Anthropometric measurements Arterial blood gas analysis Clinical observations
Participants will be randomised to receive salbutamol via either VMN or JN during NIV. We will measure the following parameters at multiple time points within one hour after nebulisation:
Neural respiratory drive via parasternal electromyography Spirometry Respiratory impedance (mechanics of breathing)
Participants will self-report breathlessness using both a numerical scale and a validated scale.
After a minimum of 48-hour washout period, participants will return to repeat the protocol with the alternative nebuliser type.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Vibrating mesh nebulisation (VMN) uses a mesh membrane that oscillates at high frequency (typically 128kHz) to produce a stream of drug-carrying droplets of pre-determined size to be inhaled
Jet nebulisers use the flow of a gas (air or oxygen) to draw medication up through a capillary tube to generate small particles to be inhaled.
Time frame: NRD assessed on both visits at baseline and 5, 15, 30 and 60 minutes after nebulisation
Change in neural respiratory drive (NRD) 30 mins following vibrating mesh or jet nebulisation with a bronchodilator (2.5mg salbutamol) during NIV. This will be measured using surface second intercostal space parasternal muscle EMG. This reflects the load-capacity relationship of the respiratory system and will likely decrease with more effective bronchodilation and secretion clearance.
Time frame: Both visits at baseline, 5 and 60 minutes post nebulisation therapy.
Change in respiratory system impedance 5 and 60 minutes after vibrating mesh or jet nebulisation therapy with 2.5mg salbutamol during NIV. Respiratory system impedance will be assessed using the forced oscillation technique (FOT).
Change in the difference in within-breath respiratory reactance at 5Hz (ΔXrs,5Hz) 5 and 60 minutes after vibrating mesh or jet nebulisation therapy with 2.5mg salbutamol during NIV, as measured by FOT
Time frame: At baseline and at 5, 15, 30 and 60 minutes post nebulisation on both visits
Breathlessness numerical rating scale: This will allow patients to report their dyspnoea and how it may change with treatment. The scale ranges from 0 to 10, where 0 indicates no breathing difficulty and 10 represents maximal breathing difficulty.
Time frame: At baseline and at 5, 15, 30 and 60 minutes post nebulisation on both visits
Patient perception of breathlessness will be assessed using the modified Borg dyspnoea scale (mBorg). The scale ranges from 0 to 10 (whole numbers plus 0.5), where - indicates no breathing difficulty and 10 represents maximal breathing difficulty.
Time frame: At baseline and for 60 minutes following nebulisation
Continuous transcutaneous carbon dioxide levels will be measured
Time frame: At baseline and during 1 hour after administration of nebuliser on both visits
Spirometry measurements of Forced expiratory volume in 1s second (FEV1)
Time frame: At baseline and during 1 hour after administration of nebuliser on both visits
Spirometry measurements of Forced vital capacity (FVC)
Time frame: At baseline and during 1 hour after administration of nebuliser on both visits
Spirometry measurements used to calculate the ratio FEV1/FVC
Time frame: At baseline and for 60 minutes following nebulisation
Assessment of cardiac rate at baseline and following administration of salbutamol via VMN and JN.
Time frame: At baseline and for 60 minutes following nebulisation
Assessment of cardiac rate and rhythm at baseline and following administration of salbutamol via VMN and JN.
Time frame: At baseline and for 60 minutes following nebulisation
Assessment of respiratory flow via pneumotrach at baseline and following administration of salbutamol via VMN and JN
Time frame: At baseline on first visit
Allows assessment of the persistence and severity of the respiratory failure in addition to being a safety check.
Guy's and St Thomas' NHS Foundation Trust
Other
Acronym: VMN-NIV
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07262229
COPD (Chronic Obstructive Pulmonary Disease), Chronic Disease
Rolle, Switzerland
View Trial DetailsNCT06969573
COPD (Chronic Obstructive Pulmonary Disease), Chronic Disease
Edmonton, Alberta, Canada
View Trial DetailsNCT06723795
COPD (Chronic Obstructive Pulmonary Disease), Cardiovascular Diseases
Tel Aviv, Israel
View Trial DetailsNCT07524023
COPD, COPD (Chronic Obstructive Pulmonary Disease)
Zurich, Canton of Zurich, Switzerland
View Trial Details