Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT06884228

Effects of Vibrating Mesh Nebulisation in Patients With COPD During Non-invasive Ventilation (VMN-NIV)

Assessment of the effects of vibrating mesh nebulisation versus jet nebulisation on the electrical activity of the muscles involved in breathing (neural respiratory drive), breathing mechanics (respiratory impedance measured by forced oscillation technique), respiratory flow, heart rate and rhythm, spirometry and breathlessness symptoms in patients with chronic obstructive pulmonary disease who require non-invasive ventilation.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Lane Fox Unit, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust

London, SE1 7EH, United Kingdom

About this study

Background Chronic obstructive pulmonary disease (COPD) remains a leading cause of morbidity and mortality in the United Kingdom. Acute exacerbations of COPD (AECOPD) frequently necessitate hospitalisation, with standard treatment comprising nebulised bronchodilators, antibiotics, and systemic corticosteroids. Approximately 20% of patients hospitalised with AECOPD require non-invasive ventilation (NIV) to manage decompensated hypercapnic respiratory failure, often necessitating concurrent administration of nebulised therapy.

Home NIV use is increasing among COPD patients to improve respiratory symptoms, quality of life, reduce hospitalisation frequency, and enhance survival. These patients may also require nebulised bronchodilator therapy during NIV, particularly when managing acute exacerbations not severe enough to warrant hospitalisation.

Currently, two nebulisation modalities are used as standard of care for patients on NIV:

Jet nebulisation (JN) - the conventional delivery method Vibrating mesh nebulisation (VMN) - a newer technology that utilises a mesh membrane oscillating at high frequency to produce drug-carrying droplets of predetermined size

VMN has been developed to optimise drug delivery in various patient populations, including those who are spontaneously breathing, receiving invasive mechanical ventilation, or on NIV. This technology is designed to enhance pulmonary drug deposition while minimising residual drug volume post-nebulisation.

Previous research has demonstrated that VMN achieves superior pulmonary drug deposition during NIV compared to JN in both healthy subjects and stable COPD patients. VMN has also been shown to produce greater improvements in forced expiratory volume in one second (FEV₁) among hospitalised patients. However, the comparative effects of these nebulisation methods on physiological parameters such as neural respiratory drive and respiratory system impedance during NIV in COPD patients with chronic respiratory failure remain unexplored.

Study Objective This pilot randomised crossover trial aims to compare the physiological effects of vibrating mesh versus jet nebulisation of salbutamol during NIV in patients with chronic respiratory failure due to COPD.

Methods Study Design A randomised crossover trial with participants receiving both interventions with a 48-hour washout period between treatments.

Participants We will recruit 12 patients with COPD currently receiving NIV under the care of the Lane Fox Unit. All participants will provide written informed consent prior to study procedures.

Procedures

Following consent, we will record baseline data including:

NIV settings Anthropometric measurements Arterial blood gas analysis Clinical observations

Participants will be randomised to receive salbutamol via either VMN or JN during NIV. We will measure the following parameters at multiple time points within one hour after nebulisation:

Neural respiratory drive via parasternal electromyography Spirometry Respiratory impedance (mechanics of breathing)

Participants will self-report breathlessness using both a numerical scale and a validated scale.

After a minimum of 48-hour washout period, participants will return to repeat the protocol with the alternative nebuliser type.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with COPD receiving home non-invasive ventilation for chronic respiratory failure under the Lane Fox Respiratory Service at Guy's and St Thomas' NHS Foundation Trust
  • Tolerating home non-invasive ventilation for at least 4 hours/24 hours
  • Aged 18-80 years old
  • Able to communicate symptom burden to the research team
  • Able to give informed consent for participation in the study
  • Clinical stability, with no acute exacerbations of COPD for 2 weeks prior to enrolment

Exclusion criteria

  • Severe, non-respiratory organ dysfunction including, but not limited to:
  • Congestive cardiac failure
  • Significant cardiovascular disease
  • End-stage malignancy
  • End-stage renal failure
  • Acute pulmonary pathology requiring emergency treatment including, but not limited to:
  • Pneumonia
  • Pneumothorax
  • Pulmonary embolism
  • Severe cognitive impairment
  • Psychosocial factors that would preclude completion of the study protocol

Treatment and study plan

Vibrating mesh nebulisation

Device

Vibrating mesh nebulisation (VMN) uses a mesh membrane that oscillates at high frequency (typically 128kHz) to produce a stream of drug-carrying droplets of pre-determined size to be inhaled

Jet nebuliser

Device

Jet nebulisers use the flow of a gas (air or oxygen) to draw medication up through a capillary tube to generate small particles to be inhaled.

Primary outcomes

  1. Change in neural respiratory drive

    Time frame: NRD assessed on both visits at baseline and 5, 15, 30 and 60 minutes after nebulisation

    Change in neural respiratory drive (NRD) 30 mins following vibrating mesh or jet nebulisation with a bronchodilator (2.5mg salbutamol) during NIV. This will be measured using surface second intercostal space parasternal muscle EMG. This reflects the load-capacity relationship of the respiratory system and will likely decrease with more effective bronchodilation and secretion clearance.

Secondary outcomes

  1. Respiratory System impedence

    Time frame: Both visits at baseline, 5 and 60 minutes post nebulisation therapy.

    Change in respiratory system impedance 5 and 60 minutes after vibrating mesh or jet nebulisation therapy with 2.5mg salbutamol during NIV. Respiratory system impedance will be assessed using the forced oscillation technique (FOT).

    Change in the difference in within-breath respiratory reactance at 5Hz (ΔXrs,5Hz) 5 and 60 minutes after vibrating mesh or jet nebulisation therapy with 2.5mg salbutamol during NIV, as measured by FOT

  2. Symptom of Breathlessness (numerical rating scale)

    Time frame: At baseline and at 5, 15, 30 and 60 minutes post nebulisation on both visits

    Breathlessness numerical rating scale: This will allow patients to report their dyspnoea and how it may change with treatment. The scale ranges from 0 to 10, where 0 indicates no breathing difficulty and 10 represents maximal breathing difficulty.

  3. Symptom of Breathlessness (modified Borg Dyspnoea scale)

    Time frame: At baseline and at 5, 15, 30 and 60 minutes post nebulisation on both visits

    Patient perception of breathlessness will be assessed using the modified Borg dyspnoea scale (mBorg). The scale ranges from 0 to 10 (whole numbers plus 0.5), where - indicates no breathing difficulty and 10 represents maximal breathing difficulty.

  4. Transcutaneous CO2 Monitoring

    Time frame: At baseline and for 60 minutes following nebulisation

    Continuous transcutaneous carbon dioxide levels will be measured

  5. Spirometry - Forced expiratory volume in 1 second

    Time frame: At baseline and during 1 hour after administration of nebuliser on both visits

    Spirometry measurements of Forced expiratory volume in 1s second (FEV1)

  6. Spirometry - Forced vital capacity

    Time frame: At baseline and during 1 hour after administration of nebuliser on both visits

    Spirometry measurements of Forced vital capacity (FVC)

  7. Spirometry ratio - FEV1/FVC

    Time frame: At baseline and during 1 hour after administration of nebuliser on both visits

    Spirometry measurements used to calculate the ratio FEV1/FVC

  8. Cardiac rate

    Time frame: At baseline and for 60 minutes following nebulisation

    Assessment of cardiac rate at baseline and following administration of salbutamol via VMN and JN.

  9. Cardiac rhythm

    Time frame: At baseline and for 60 minutes following nebulisation

    Assessment of cardiac rate and rhythm at baseline and following administration of salbutamol via VMN and JN.

  10. Respiratory flow

    Time frame: At baseline and for 60 minutes following nebulisation

    Assessment of respiratory flow via pneumotrach at baseline and following administration of salbutamol via VMN and JN

Other outcomes

  1. Arterial blood gas

    Time frame: At baseline on first visit

    Allows assessment of the persistence and severity of the respiratory failure in addition to being a safety check.

Sponsors and collaborators

Lead sponsor

Guy's and St Thomas' NHS Foundation Trust

Other

Registry information

Acronym: VMN-NIV

Important dates

Study start
2025
Primary completion
2025
Study completion
2026
First posted
Mar 19, 2025
Registry last updated
Jul 10, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.