NCT Number: NCT01892696
The clinical usefulness of inspiratory flow pattern manipulation during mechanical ventilation remains unclear. The aim of this study was to investigate the effects of different inspiratory flow waveforms, i.e. constant and decelerating, on cardiac preload in mechanically ventilated patients assessed by arterial pulse pressure variation (PPV) and inferior vena cava distensibility.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
Tunis, Mont Fleury, 1008, Tunisia
During mechanical ventilation the lungs can be inflated with different pressure and flow waveforms. Originally the piston-driven mechanical ventilators generated a quasi-sinusoidal flow waveform, whereas the newer electronically controlled ventilators can also produce constant and decelerating waveforms. According to several theoretical,animal and clinical studies,the inspiratory flow waveform affects the distribution of the inspired gas as well as respiratory mechanics and gas exchange. However, other studies failed to show any significant effect.But there is no study interested to the effects of inspiratory flow waveforms on cardiac preload. Thus, the clinical usefulness of inspiratory flow pattern manipulation remains unclear, though the capacity for selection of different inspiratory flow waveforms is provided by most modern, microprocessor-equipped ventilators. Therefore, the purpose of this study was to compare the effects of flow patterns (sinusoidal, constant and decelerating) on dynamic measurements of cardiac preload dependence such as arterial pulse pressure variation (ΔPP) and distensibility index of the inferior vena cava (dIVC).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
inspiratory flow waveform was changed, in a randomized sequence using a computer ,to one of the following modalities: 1) constant inspiratory flow; 2) decelerating inspiratory flow Each inspiratory flow waveform was maintained for 30 min. During the last 5 min of this period the physiological signals were collected and measures were performed.
Time frame: 2h
Each inspiratory flow waveform was maintained for 30 min with 60 minutes washout period
Military Hospital of Tunis
Other
Arterial Pulse Pressure Variation and Inferior Vena Cava Distensibility Affected by Inspiratory Flow Waveforms in Mechanically Ventilated Patients: Time for a Change
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02728791
Cardiac Output, Low, Cardiovascular Diseases
Brest, France
View Trial DetailsNCT04871620
Cardiac Output, Low, Cardiovascular Diseases
Nîmes, France
View Trial DetailsNCT05905536
Cardiac Output, Low, Cardiovascular Diseases
Winston-Salem, North Carolina, United States
View Trial DetailsNCT05070819
Cardiac Disease, Cardiac Output, High
Moscow, Russia
View Trial Details