HF-rTMS
DeviceHF-rTMS stimulated a 70-mm, 8-shaped coil stimulator (The Magstim Company, UK, 2012) on the damaged cerebral cortex. Prior to the application of HF-rTMS, the motor point was identified that stimulates maximum thresholds on the primary motor cortex, causing flexion of the opposite index finger. If the cerebral hemisphere does not show a kinetic response even at the maximum stimulus, the motor point of the opposite hemisphere was found to be symmetrically changed. The intensity of the stimulus was 80% of the resting motor threshold, which means the motor eveked potential above which the first dorsal interosseous muscle can produce 50 μV more than five times out of 10 stimuli. The subject sat on a chair made to hold the head. The stimulation was stimulated at high frequency (10 Hz) for 2 seconds, and the rest was performed for 58 seconds for a total of 200 times for 10 minutes.
Other names: High Frequency repetitive Transcranial Magnetic Stimulation(HF-rTMS)