Donders Institute for Brain, Cognition and Behaviour
Nijmegen, Gelderland, 6511EN, Netherlands
NCT Number: NCT06886178
Parkinson's disease is a neurodegenerative condition that leads to uncontrollable shaking (tremor), which can substantially impair everyday activities. The goal of this clinical trial is to learn if the STIL Orthosis works as a treatment option for tremor in people with Parkinson's disease. The main questions it aims to answer are:
* Does the STIL Orthosis reduce tremor? * Are users satisfied with the usability and comfort of the STIL Orthosis? * Does the STIL Orthosis have any adverse effects?
Participants' tremor will be measured during three conditions:
* While wearing the STIL Orthosis * While wearing an orthosis without dampening (sham) * While wearing no orthosis (baseline)
Researchers will compare the severity of tremor while wearing the STIL Orthosis against tremor during sham and baseline.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Nijmegen, Gelderland, 6511EN, Netherlands
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
STIL Orthosis, a brace for the arm equipped with passive dampening designed to suppress high-frequency movements.
A version of the STIL Orthosis that is visually indistinguishable from original, but which does not have the passive dampening mechanism.
Time frame: Day 1
Tremor severity is assessed using the Tremor Research Group Essential Tremor Rating Scale (TETRAS), which is a validated scale specifically designed for essential tremor, the most common action tremor worldwide.
TETRAS will be rated by two independent assessors, based on a video recording. The scale covers 7 postural and kinetic tasks (postural outstretched arms, postural wing beating, finger-to-nose maneuver, eating, drinking, pouring, Archimedes spiral), which are selected to accurately represent the difficulties that PD patients experience with per-forming ADL tasks. A TETRAS score is rated on the baseline, and for the sham and STIL Orthosis conditions. Tremor is rated on a 0 to 4 scale per task, with 0 indicating no visible tremor and 4 indicating a tremor with an amplitude exceeding 20 cm. Combining the 7 tasks from the TETRAS scale, a maximum sum score of 28 points can be achieved per condition.
Time frame: Day 1
Tremor severity is also assessed using the MDS-UPDRS part III scale. Items 15, 16, and 17, of the MDS-UPDRS part III for postural, kinetic, and rest tremor will be used for assessment of the arm, respectively. Tremor is rated on a 5-point scale, with 0 indicating no tremor and 4 indicating a tremor with an amplitude of at least 10 cm. Note that the tasks for this rating are distinct from the TETRAS scale.
Time frame: Day 1
Quantification of tremor power will be based on movement data from accelerometry and using surface electromyography (sEMG). Again, the same 7 tasks (postural out-stretched arms, postural wing beating, finger-to-nose manoeuvre, eating, drinking, pour-ing, Archimedes spiral) and resting posture are used to compare baseline, sham and in-tervention conditions. Tremor power is obtained through signal processing.
Time frame: Day 1
Perceived change in tremor while wearing the sham and STIL Orthosis, using the Patient Global Impression of Improvement (PGI-I) scale. This questionnaire is a single-item scale that measures a patient's perception of improvement or deterioration in their condition following treatment. Answers range from 'very much improved' to 'very much wors-ened'.
Time frame: Day 1
User satisfaction is evaluated with a subset of the Dutch Quebec User Evaluation of Satisfaction with Assistive Technology (D-QUEST) (Demers et al., 2001 & 2002). This questionnaire consists of 8 questions regarding comfort and usability of the device itself and 5 questions about the service of the manufacturer. Only 4 questions about satisfaction of the device itself will be questioned. Satisfaction is measured on a 1-5 scale, ranging from 'completely not satisfied' to 'very satisfied'. Additional questions regarding comfort will be asked to examine possible adverse-effects more detailed.
Time frame: Day 1
Product safety will be assessed using the Dutch version of NCCIH's Adverse Events Report Form. This form is used to report the severity, relationship to the study, taken action, outcome of the (S)AE and whether it was expected or not.
Radboud University Medical Center
Other
The Effect of the STIL Orthosis on Action Tremor Severity in People With Parkinson's Disease
Acronym: STIL-PD
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06724029
Aneurysm, Aneurysms
Bergamo, BG, Italy
View Trial DetailsNCT07092995
Freezing of Gait, Freezing of Gait Symptoms in Parkinson&Amp;#39;s Disease
Los Angeles, California, United States
View Trial DetailsNCT06816810
Inflammation, Nervous System Diseases
Ottawa, Ontario, Canada
View Trial DetailsNCT06772220
Basal Ganglia Diseases, Brain Diseases
Portland, Oregon, United States
View Trial Details