Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07402252

Effectiveness and Safety of a Type A Dissection Total Endovascular Reconstruction System in Promoting Favorable Distal Aortic Remodeling

This is a prospective, multicenter, randomized controlled clinical study. A total of 198 eligible subjects will be enrolled and randomly assigned in a 1:1 ratio to either the Study Group or the Control Group. Subjects in the Study Group will receive surgical treatment using the study device (Type A Dissection Total Endovascular Reconstruction System) in addition to standard medical therapy following the Total Arch Replacement with Frozen Elephant Trunk. Subjects in the Control Group will continue standard medical therapy without surgical treatment using the study device following Total Arch Replacement with Frozen Elephant Trunk. Clinical follow-ups will be conducted at 30 days (±7 days), 6 months (±30 days), and 12 months (±30 days) post-enrollment to evaluate the effectiveness and safety of the study device.

After all subjects complete the 12-month (±30 days) follow-up, a statistical analysis will be performed and the results will be submitted for the study device registration application. Long-term follow-up will continue for 2-5 years post-enrollment.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥18 years, male or female.
  • Within 90 days of onset of Stanford Type A Aortic Dissection and 30 days post Total Arch Replacement with Frozen Elephant Trunk treatment (assessed via CTA at 30±7 days post open surgery):
  • Presence of any intimal tear in the residual dissection of the thoracic aorta and the false lumen is not completely thrombosed.
  • The intercostal arteries in the segment of the residual thoracic aortic dissection are primarily supplied by the false lumen (number of intercostal arteries supplied by false/mixed lumen > number supplied by true lumen; only intercostal arteries filled with contrast agent are considered).
  • False lumen volume in the thoracic aorta distal to the frozen elephant trunk stent graft is >50% of the total aortic lumen volume.
  • Voluntarily participate in this study and provide signed informed consent.

Exclusion criteria

  • Presence of a proximal anastomotic leak at the frozen elephant trunk site post open surgery.
  • No left subclavian artery revascularization during the open surgery.
  • Presence of severe endoleak, or residual dissection expansion ≥55mm, or distal stent graft-induced new entry.
  • History of myocardial infarction, or stroke (with clear symptoms/signs and culprit lesion), or bowel ischemia within 1 month prior to the procedure.
  • Previous history of descending thoracic or abdominal aortic surgery.
  • Lack of suitable vascular access.
  • Known allergy to components of the study device (e.g., Nitinol) or contrast agent.
  • Renal insufficiency (creatinine >2.5 times the upper limit of normal) or requiring long-term regular dialysis.
  • Severe liver dysfunction (Child-Pugh Class C).
  • Active bleeding, coagulation disorders, thrombocytopenia (platelet count <50×109/L), or refusal of blood transfusion.
  • Uncontrolled severe infection and associated sepsis, shock, or multiple organ failure.
  • Life expectancy less than 12 months (due to conditions other than aortic dissection).
  • Known or suspected connective tissue degenerative disease, or family history of aortic dissection.
  • Pregnant or lactating women.
  • Concurrent participation in other drug or medical device clinical studies.
  • Subjects deemed unsuitable for participating the study by the investigator.

Treatment and study plan

surgical treatment

Device

Endovascular repair with study device following the Total Arch Replacement with Frozen Elephant Trunk for Stanford Type A Aortic Dissection.

Standard of Care (Investigator Choice)

Drug

Standard medical therapy (e.g., blood pressure and heart rate control)

Primary outcomes

  1. Change in False Lumen Volume of the Distal Aortic Dissection at 12 months

    Time frame: 12 months (±30 days) post-enrollment

    Defined as the difference in the false lumen volume of the distal aortic dissection (distal to the frozen elephant trunk stent, including thrombosis portions) at baseline and 12 months (±30 days) post-enrollment among subjects in the Study group and Control group, respectively

  2. The incidence of major adverse events (MAEs) within 30 days

    Time frame: 30 days (±7 days) after enrollment

    The percentage of subjects in the study or control group who experience any MAEs within 30 days (±7 days) after enrollment, relative to the total number of subjects in each group.

Secondary outcomes

  1. Procedure Success Rate (%) (Immediate post-procedure) (Study Group only)

    Time frame: Immediately post procedure

    The percentage of subjects in the study group who achieved procedure success immediately after procedure out of the total number of subjects in the study group. Procedure success is defined as successful delivery and positioning of the system, accurate deployment of the stent, successful retrieval of the delivery system, no conversion to open surgical thoracotomy during the procedure, subject survival at the end of the procedure, and no Type I or III endoleak on angiography in the covered stent-graft segment.

  2. Treatment Success Rate (%) (12 months) (Study Group only)

    Time frame: 12 months (±30 days) after enrollment

    The percentage of subjects in the study group who achieved treatment success at 12 months (±30 days) after enrollment out of the total number of subjects in the study group.

  3. Change in True Lumen Volume of the Distal Aortic Dissection (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment.

    The difference in the volume change of the true lumen of distal aortic dissection (distal to the frozen elephant trunk stent, thoracic and abdominal segments) at baseline, 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) post-enrollment among subjects in the Study group and Control group, respectively.

  4. Change in False Lumen Volume of the Distal Aortic Dissection (at 30 days, 6 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), and 2-5 years (±30 days) after enrollment

    The difference of change in the false lumen volume of distal aortic dissection (distal to the frozen elephant trunk stent, thoracic and abdominal segments, including thrombosis portions) at baseline, 30 days (±7 days), 6 months (±30 days), and 2-5 years (±30 days) post-enrollment among subjects in the Study group and Control group, respectively.

  5. Change in Maximum Diameter of the Distal Aorta (True + False Lumen) (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment

    The difference in the maximum diameter change of the entire distal aorta (true lumen + false lumen, distal to the frozen elephant trunk stent, thoracic and abdominal segments) at baseline, 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) ost-enrollment among subjects in the Study group and Control group, respectively.

  6. Thrombosis Status of the False Lumen in the Distal Aortic Dissection (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment

    The qualitative and/or quantitative assessment of thrombosis status in the false lumen of distal aortic dissection (aortic segment from the distal end of the frozen elephant trunk stent to the superior edge of the celiac trunk origin) for subjects in the study or control group at 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) post-enrollment, based on CTA imaging and aortic reconstruction models.

  7. Rate of Secondary Intervention Related to the Distal Aortic Dissection (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment.

    The percentage of subjects in the study or control group who meet the indications for secondary intervention related to distal aortic dissection within 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) post-enrollment, relative to the total number of subjects in each group.

  8. Survival Rate (6, 12 months, 2-5 years)

    Time frame: 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment

    The percentage of subjects in the study or control group with no all-cause death or aortic-related death at 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment, relative to the total number of subjects in each group.

  9. Incidence of MAE (6, 12 months, 2-5 years)

    Time frame: 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment

    MAEs include any of the following aortic-related events: death, stroke, myocardial infarction, paraplegia/spinal cord ischemia, intestinal ischemia/necrosis requiring intervention, new-onset renal failure requiring replacement therapy, or respiratory failure requiring prolonged mechanical ventilation or reintubation.

  10. Incidence of Paraplegia/Spinal Cord Ischemia (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment.

    The percentage of subjects in the study or control group who develop paraplegia or spinal cord ischemia within 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment, relative to the total number of subjects in each group.

  11. Incidence of Acute Kidney Injury (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment.

    The percentage of subjects in the study or control group who develop acute kidney injury within 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment, relative to the total number of subjects in each group.

  12. Incidence of Stroke (at 30 days, 6, 12 months, 2-5 years)

    Time frame: 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment

    The percentage of subjects in the study or control group who experienced a stroke within 30 days (±7 days), 6 months (±30 days), 12 months (±30 days), and 2-5 years (±30 days) after enrollment, relative to the total number of subjects in each group.

  13. Incidence of Stent Migration (at 30 days, 6, 12 months) (Study Group only)

    Time frame: 30 days (±7 days), 6 months (±30 days), and 12 months (±30 days) after enrollment.

    The percentage of subjects in the study group with stent displacement within 30 days (±7 days), 6 months (±30 days), and 12 months (±30 days) after enrollment, relative to the total number of subjects in each group.

  14. Incidence of AE/SAEs

    Time frame: Through study completion, an average of 5 year

    AE refers to any unfavorable medical event occurring during a clinical trial, whether or not related to the study device.

  15. Incidence of Device Deficiencies (Study Group only)

    Time frame: Through study completion, an average of 5 year

    A device deficiency refers to any unreasonable risk that may endanger human health and safety during normal use of the medical device in a clinical trial, such as label errors, quality issues, malfunctions, etc.

Study contacts

Contact information is provided by the study sponsor or research team.

Sponsors and collaborators

Lead sponsor

West China Hospital

Other

Registry information

Official study title

Effectiveness and Safety of a Type A Dissection Total Endovascular REconstruction System in Promoting Favorable Distal AOrtic ReModeling After Total Arch Replacement With Frozen Elephant Trunk for Type A Aortic Dissection: A Prospective, Multicenter, Randomized Controlled Trial

Acronym: REFORM-TAD

Important dates

Study start
2026
Primary completion
2027
Study completion
2031
First posted
Feb 11, 2026
Registry last updated
Feb 11, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.