Asmaa Maher Ahmed Zahran
Giza, 12511, Egypt
NCT Number: NCT05900856
the aim of this study is to investigate the efficacy of ultrasound cavitation on static and dynamic balance in obese postnatal women with diastasis recti
Looking for future studies?
Notify Me25 year–35 year
Female
Interventional
Not applicable
Giza, 12511, Egypt
Rectus diastasis defined as the widening of the linea alba by more than 2 cm at the midline. A great proportion of pregnant women are complaining from rectus diastasis during pregnancy reaching 100% of all women that may continue for years after delivery in 66% of women, and do not return to the first state automatically. This occurs due to a combination of physiologic, hormonal and mechanical factors, leading to reduction of abdominal muscle functional strength, increased low back pain out of increased lumbar hyperlordosis and postural instability, which may seriously disable woman from taking care of her baby, perform her daily activities. Weight gain is one of the predisposing factors that increases the possibility of developing rectus diastasis postpartum. Being obese increases liability to have rectus diastasis as carrying excess abdominal fats puts greater pressure against linea alba and can develop or aggravate symptoms for both men and women. This massively displaces the center of gravity anteriorly, disturbs body balance, increases joint loads and influences negatively pelvis posture leading to increased anterior pelvic tilt with subsequent exaggerated lumbar hyperlordosis. Ultrasound cavitation is the most revolutionary method that destroys excess body fat through creating microbubbles and releasing energy that breaks down fat cells. This trial has two groups: one will be treated by low caloric diet regimen only and the second one will be treated by ultrasound cavitation in addition to low caloric diet regimen for eight weeks
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
lipids approximately (20: 35%) of total caloric intake, protein approximately (10: 35%) of total caloric intake and high complexed carbohydrate intake approximately (45: 65%) of total caloric intake (with increased fiber-rich whole grain breads, cereals, fruits and vegetables), for eight weeks.
Other names: hypocaloric diet (1600: 2000 Kcal/ day)
patients will assume standing position, the abdominal area will be divided vertically into 2 equal sections, right and left segment, extending bilaterally from the line stretching between the mid axilla above and the iliac crest below, and upward from center of diaphragm to the midpoint extending between two iliac crest below, then from supine lying position the cavitation head will be applied on each abdominal segment for 15 minutes with total treatment time 30 minutes twice per week for eight weeks
Other names: Dae Yang, Mabel 6, serial number DY73-15037, produced by DAEYANG MEDICAL company
Time frame: up to eight weeks
The Biodex Balance System SD (model: TP-3040-15, DC input: 19V-6.32A, connected to computer software version 4.0.06, 2017, serial number: R712010010, made in Taiwan) will be used to measure overall stability index of static postural balance for all patients
Time frame: up to eight weeks
The Biodex Balance System SD (model: TP-3040-15, DC input: 19V-6.32A, connected to computer software version 4.0.06, 2017, serial number: R712010010, made in Taiwan) will be used to measure overall stability index of dynamic postural balance for all patients
Time frame: up to eight weeks
Ultrasound imaging unit (Mindary DP10, linear probe, with 10 MHz frequency, serial number: bn- 75013216, made in China) will be used to measure abdominal subcutaneous fat thickness at the umbilical level from supine lying position for all patients
Time frame: up to eight weeks
Ultrasound imaging unit (Mindary DP10, convex probe, with 5 MHz frequency, serial number: bn- 75013216, made in China) will be used to measure resting inter recti distance 2.5 cm above the upper margin of umbilicus from crock lying position for all patients
Time frame: up to eight weeks
Spinal mouse (MEDIMOUSE) IDIAG M360 pro, pc-Software, 7.4.0., serial number: *112D2A24*, made in Switzerland) will be used to measure lumbar lordotic angle from standing position
Cairo University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05446675
HERNIA, VENTRAL, Hernia
Eeklo, Oost-Vlaanderen, Belgium
View Trial DetailsNCT05287282
Rectus Diastasis
Tanta, Egypt
View Trial DetailsNCT07426770
Female Urinary Incontinence and Pelvic Organ Prolapse, Pathological Conditions, Anatomical
Vilnius, Lithuania
View Trial DetailsNCT07037368
Musculoskeletal Pain, Neurologic Manifestations
Lahore, Punjab Province, Pakistan
View Trial Details