Centre for Nutrition Research, University of Navarra
Pamplona, Navarre, 31008, Spain
NCT Number: NCT03610776
Randomised within subjects cross-over study (n=94) exploring the cognitive and physiological processes associated with portion control. Participants will eat a self-served lunch using a portion control plate vs. a conventional (control) plate on two separate occasions under a controlled laboratory environment. Portion size, meal micro-structure, attention, memory and satiety markers will be analysed. The portion control plate is a prototype designed in collaboration with the commercial partner for this study and is based on published evidence. It includes sectors and pictures indicating amounts to serve from starchy food, protein and vegetables. The control plate will be of the same background colour, size and shape but without any pictures or demarcations. The main study outcome is attention time on areas of interest in the plate corresponding to main foods groups, across plate conditions.
Looking for future studies?
Notify Me18 year–60 year
All sexes
Interventional
Not applicable
Pamplona, Navarre, 31008, Spain
The size and design of tableware have been proposed as a potentially effective strategy to modulate how much is eaten at a meal. The mechanisms by which specific tableware may work however are not known, in particular the cognitive processes associated with visual stimuli. In this covert trial, 68 women (34 overweight or obese) and 26 lean men (exploratory sub-study) will self-serve and consume food from a laboratory buffet using a portion control plate with visual stimuli for appropriate amounts of main food groups, or a conventional plate, on two different days in random order. On both sessions participants will complete behavioural and cognitive tests to measure visual attention during the meal (eyetracking device), meal microstructure (Universal Eating Monitor), episodic memory for portion sizes (computerised test), portion size choice, food intake, subjective appetite and satiety, cephalic and intestinal satiety responses. Further behavioural tests include meal liking, expected satiety, portion size perceptions and tool acceptance ratings. The main study outcome is difference in proportional dwell time on areas of interest in the plate corresponding to main foods groups (women), or difference in bite size (men) across conditions. Secondary outcomes for all subjects include: portion size for overall meal and meal components, eating rate, bite size, deceleration rate, portion size memory error, portion size norms, portion control self-efficacy, tool acceptance, energy compensation for the rest of the day, plus blood insulin, glucose, pancreatic polypeptide and ghrelin up to 90 min post-meal (sub-sample of 34 women, 50% being overweight/obese). Analyses by gender and BMI sub-groups will be applied when possible. The results of this study will help to better understand the potential mechanisms by which portion control tools with visual cues may work, and to improve the design of current instruments for their application in nutritional interventions.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Portion control plate including demarcations and pictures for recommended amounts of main food groups (starch, protein and vegetables), 25 cm in diameter, enamel, white background.
Other names: Calibrated plate
Conventional plate without demarcations or images, 25 cm in diameter, enamel, white.
Other names: Control plate
Time frame: Month 24
Difference in proportional dwell time on three areas of interest in the plate corresponding to main food groups i.e. starch, protein and vegetables, measured in milliseconds, as a proxy for attention levels, between the Portion Control Plate condition and the conventional plate condition.
Time frame: Month 24
Difference in the amount of food loaded on the fork estimated from the difference in grams between two consecutive weight records as measured by the Universal Eating Monitor, between the Portion Control Plate condition and the conventional plate condition.
Time frame: Month 24
Difference in grams of food consumed per minute as measured by the Universal Eating Monitor, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in the amount of food loaded on the fork estimated from the difference in grams between two consecutive weight records as measured by the Universal Eating Monitor, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in the change in eating rate over the course of the meal measured in grams per squared second, as recorded by the Universal Eating Monitor, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in the duration of the meal in minutes, starting when the investigator places the food on the table and finishing when the volunteer pressed the bell, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in proportional dwell time on three areas of interest in the plate corresponding to main food groups i.e. starch, protein and vegetables, measured in milliseconds, as a proxy for attention levels, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in portion sizes in grams for the complete meal and for each meal component (i.e. rice, vegetables, meatballs, bread, fruit, condiments and water), between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Percent error between recalled and real portion size calculated by subtracting the recalled portion size for each meal component at 3 hours post-meal, from the actual portion sizes chosen during the test meal and dividing by the actual portion size, using data from a computer-based memory reconstruction task (XnConvert software), for the Portion Control Plate condition. Interpreted as 0% = perfect match between recalled and actual portion size.
Time frame: Month 21
Percent error between recalled and real portion size calculated by subtracting the recalled portion size for each meal component at 3 hours post-meal, from the actual portion sizes chosen during the test meal and dividing by the actual portion size, using data from a computer-based memory reconstruction task (XnConvert software), for the conventional plate condition. Interpreted as 0% = perfect match between recalled and actual portion size.
Time frame: Month 24
Difference in the percent memory reconstruction error for each meal component at 3 hours post-meal, between the Portion Control Plate and the conventional plate condition.
Time frame: Month 21
Energy adjustment after the meal and for the remaining of the day, calculated from food intake data collected via an 8h food diary and using a published algorithm (Almiron-Roig et al. 2013). Interpreted as EC of 100% = perfect compensation; <100% = undercompensation; >100% overcompensation.
Time frame: Month 24
Difference in percent energy compensation after the meal and for the remaining of the day, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Visual analogue scale ratings (0 -100 mm) for habitual portion size for the meal, rice, vegetables and meatballs consumed during the test meal. Interpreted as: a score of 50 mm = the chosen portion equals the habitual portion size; >50 mm = chosen portion is smaller than habitual; <50 mm = chosen portion is larger than habitual.
Time frame: Month 24
Difference in Visual Analogue Scale ratings for portion size norms for the whole meal, rice, vegetables and meatballs between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in visual analogue scale ratings (0-100 mm) for Liking of the meal after consumption between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived hunger before the meal (time 0)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived fullness before the meal (time 0)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived thirst before the meal (time 0)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived nausea before the meal (time 0)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived hunger immediately after the meal (time 1)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived fullness immediately after the meal (time 1)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived thirst immediately after the meal (time 1)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived nausea immediately after the meal (time 1)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived hunger 3 hours after consuming the meal (time 2)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived fullness 3 hours after consuming the meal (time 2)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived thirst 3 hours after consuming the meal (time 2)
Time frame: Month 21
Visual analogue scale ratings (0-100 mm) for perceived nausea 3 hours after consuming the meal (time 2)
Time frame: Month 24
Difference in scores of visual analogue scale ratings (0-100 mm) for perceived hunger, fullness, thirst and nausea at baseline, post-meal and 3 hours after consuming the meal, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 24
Difference in visual analogue scale rating (0-100 mm) before consuming the meal, between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Blood glucose levels before starting the meal
Time frame: Month 21
Blood glucose levels at 5, 10, 30, 60 and 90 min after starting the meal
Time frame: Month 21
Difference in blood glucose levels at 5, 10, 30, 60 and 90 min after starting the meal between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Blood insulin levels before starting the meal
Time frame: Month 21
Blood insulin levels at 5, 10, 30, 60 and 90 min after starting the meal
Time frame: Month 24
Difference in blood insulin levels at 5, 10, 30, 60 and 90 min after starting the meal between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Blood pancreatic polypeptide levels before starting the meal
Time frame: Month 21
Blood pancreatic polypeptide levels at 5, 10, 30, 60 and 90 min after starting the meal
Time frame: Month 24
Difference in blood pancreatic polypeptide levels at 5, 10, 30, 60 and 90 min after starting the meal between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 21
Blood ghrelin levels before starting the meal
Time frame: Month 21
Blood ghrelin levels at 5, 10, 30, 60 and 90 min after starting the meal
Time frame: Month 24
Difference in blood ghrelin levels at 5, 10, 30, 60 and 90 min after starting the meal between conditions (Portion Control Plate vs. conventional plate).
Time frame: Month 18
Weight in kilograms divided by height in squared meters measured at the start of the trial.
Time frame: Month 18
Age in years measured at the start of the trial.
Time frame: Month 21
Restraint, disinhibition and susceptibility to hunger scores from the Three Factor Eating Questionnaire for the Spanish population (Sánchez-Carracedo et al. 1999, Psicol Conduct 7:393-416) measured at the end of the trial.
Time frame: Month 18
Susceptibility to eating disorders score using the Eating Attitudes Test (EAT-26) the Spanish population (Rivas et al. 2010; Span J Psychol 13:1044-1056) measured at the start of the trial.
Time frame: Month 24
Difference in portion control self-efficacy score derived from the Portion Control Self-Efficacy Scale (Fast et al.2015) between conditions (Portion Control Plate vs. conventional plate). The scale ranges from 1 to 5. A combined score will be obtained for questions 1,2, 3, 5, 7,8 and the reverse of questions 4 and 6, by adding up all the scores from each of the 8 Likert scales, and dividing the sum by 8. A score between 1-2.5 will be interpreted as 'none to low self-efficacy'; a score between 2.5-3.5 will be interpreted as 'neutral self-efficacy', a score between 3.5-5 will be interpreted as 'medium to high self-efficacy'.
Time frame: Month 24
Difference in portion tool acceptance score derived from a published questionnaire (Almiron-Roig et al., 2016) between conditions (Portion Control Plate vs. conventional plate). A combined score will be obtained for questions a, b, c, e, f, g and the reverse of d by adding up all the scores from each of the 4 Likert scales, and dividing the sum by 7. A score between 1-2.5 will be interpreted as 'none to low acceptance'; a score between 2.5-3.5 will be interpreted as 'neutral acceptance', a score between 3.5-5 will be interpreted as 'medium to high acceptance'.
Time frame: Month 18
Ethnicity group defined using a check-list, measured at the start of the trial.
Time frame: Month 18
Number of adults and children aged 18 or less living in the same household (checklist) measured at the start of the trial.
Time frame: Month 18
Frequency of take away food consumption (checklist), measured at the start of the trial.
Time frame: Month 18
Frequency of home-made meal consumption (checklist), measured at the start of the trial.
Time frame: Month 18
Cooking for self only vs. cooking for self and others (checklist), measured at the start of the trial.
Time frame: Month 18
Previous experience with portioning utensils, portion control tools, measuring utensils etc. (open ended question), measured at the start of the trial.
Time frame: Month 21
8h food record to complete after the laboratory test meal, for both conditions (Portion Control Plate and conventional plate).
Time frame: Month 18
Visual analogue scale ratings (0-100 mm) for liking of the rice, peas, carrots and meatballs, measured during a sensory test at the start of the trial (laboratory screening session).
Time frame: Month 18
Self-reported number of cigarettes per day measured at the start of the trial (telephone screening interview).
Time frame: Month 18
Self-reported number of hours of moderate to intense physical activity per week, measured at the start of the trial (telephone screening interview).
Clinica Universidad de Navarra, Universidad de Navarra
Other
Role of Visual Cues in the Regulation of Portion Size and the Cephalic Satiety Response in Lean and Overweight Subjects
Acronym: PORTIONS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03811210
Portion Size
Liverpool, Merseyside, United Kingdom
View Trial DetailsNCT03731273
Portion Size
Liverpool, Merseyside, United Kingdom
View Trial Details