NCT Number: NCT05220007

Effect of Presbyopic Correction Lens on Humphrey Visual Field Testing in Patients With Multifocal Intraocular Lens

Purpose of this study was to evaluate the effect of presbyopic correction lens on Humphrey visual field (HVF) testing in patients with 2 models of multifocal intraocular lens (MIOL) both with and without glaucoma. All participants performed HVF testing with presbyopic collection lenses and without presbyopic collection lenses on the same occasion (5-10 minutes between the test). The mean deviation (MD) and pattern standard deviation (PSD) were compared between with and without presbyopic collection lenses, between glaucoma and non-glaucoma and between 2 models of MIOL.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Naris Kitnarong

Bangkoknoi, Bangkok, 10700, Thailand

About this study

This was a prospective comparative study in patients who underwent uneventful phacoemulsification with MIOL implantation at the Department of Ophthalmology, Faculty of Medicine, Siriraj Hospital, Mahidol University between June 2009 to July 2012. The study protocol was approved by the Siriraj Institutional Review Board complied with all of the principles set forth in the Declaration of Helsinki (1964) and its subsequent amendments. (certificate of approval number Si 003/2010). The written informed consent was obtained from each participant prior to participation. Each patient received a comprehensive eye examination with slit-lamp biomicroscopy, distant and near visual acuity, and auto-refraction. The eligible participants performed HVF 24-2 or 30-2 on the enrollment day with and without presbyopic correction lens. The participants were randomized to perform HVF with presbyopic collection lenses followed by without presbyopic collection lenses or without presbyopic collection lenses followed by with presbyopic collection lenses by simple randomization. Data collection included demographic data, distant (logMar) and near (Jaeger reading chart) BCVA, and HVF test result including mean deviation (MD), pattern standard deviation (PSD), test duration (minute), fixation loss, false positive, and false negative.

Multifocal intraocular lens characteristics There were two types of aspheric diffractive MIOL included in the study: TECNIS ZM900 (Abbott Medical Optics Inc, Santa Ana, CA, USA) and AcrySof IQ ReSTOR SN6AD1 (Alcon Laboratories, Inc., Irvine, CA, USA). The TECNIS ZM900 is a silicone 3-piece aspheric diffractive lens. The power of the add is +4.00 D with a 50/50 distance/near light distribution. The AcrySof IQ ReSTOR SN6AD1is an acrylic single-piece aspheric diffractive lens. The power of the add is +3.00 D with a 65/35 light distribution.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Glaucomatous and non-glaucomatous patients
  • Age older than 18 years
  • A history of uneventful phacoemulsification with MIOL implantation at least one month before participation
  • Distant best-corrected visual acuity (BCVA) equal to or better than 20/30
  • Near BCVA of at least Jaeger 2

Exclusion criteria

  • The inability to perform reliable visual field testing (fixation loss, false positive or false negative more than 25%)
  • A history of postoperative complications
  • Moderate to advanced visual field defects (MD less than - 6 dB)
  • Any other concurrent ocular diseases, except well-controlled glaucoma.

Treatment and study plan

Humphrey visual field testing

Diagnostic Test

Perimetry was performed with the Humphrey Field Analyzer (Carl Zeiss Meditec Inc). Participants performed a 30-2 or a 24-2 Swedish Interactive Threshold Algorithm (SITA) standard test with stimulus size III, and standard Humphrey background luminance of 31.5 apostilbs. The participants were selected by simple random sampling to perform the HVF test with presbyopic collection lenses followed by without presbyopic collection lenses, or without presbyopic collection lenses followed by with presbyopic collection lenses. The power of presbyopic correction lens at the testing distance of 33 cm (the bowl radius) was auto-calculated according to the recommendation by the Humphrey Field Analyzer's manufacturer, depending on the current refractive error and the patient's age.

Primary outcomes

  1. Mean deviation

    Time frame: at 1 day after enrollment

    Mean deviation from Humphrey visual field testing

  2. Pattern standard deviation

    Time frame: at 1 day after enrollment

    Pattern standard deviation from Humphrey visual field testing

Secondary outcomes

  1. Fixation loss (percent)

    Time frame: at 1 day after enrollment

    Fixation loss from Humphrey visual field testing

  2. False negative (percent)

    Time frame: at 1 day after enrollment

    False negative from Humphrey visual field testing

  3. False positive (percent)

    Time frame: at 1 day after enrollment

    False positive from Humphrey visual field testing

  4. Test duration (minutes0

    Time frame: at 1 day after enrollment

    Test duration from Humphrey visual field testing

Sponsors and collaborators

Lead sponsor

Siriraj Hospital

Other

Registry information

Important dates

Study start
2009
Primary completion
2012
Study completion
2021
First posted
Feb 2, 2022
Registry last updated
Feb 2, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.