National Research Centre
Cairo, El- Dokki, Egypt
NCT Number: NCT04701970
evaluation of occlusal force distribution was carried out with the aid of T-Scan device (Tekscan Inc., South Boston, MA, USA) for mandibular complete dentures before and after relining with long term soft liner for controlled type 2 diabetic patients.
Looking for future studies?
Notify Me49 year–63 year
Male
Interventional
Not applicable
Cairo, El- Dokki, Egypt
A crossover clinical study was carried out with previously constructed and used conventional complete dentures before relining with soft denture liners and then with the same dentures after relining with soft denture liners. The study sample included 50 males completely edentulous contributors, All patients were controlled type 2 diabetes during the study period. All selected patients had previously constructed and used conventional heat cured acrylic resin complete dentures for not less than two years with history of retention and stability problems of mandibular dentures. Mandibular complete dentures had received the essential prosthetic adjustments aiming to achieve optimal retention, maximum stability and the necessary occlusal contacts. The first occlusal parameters were recorded before denture relining. Relining of mandibular dentures was performed and Patients were comfortably using their relined mandibular complete dentures for at least three months and the retention and stability of the conventional dentures were assessed before second recording of occlusal parameter. The evaluation of occlusal force distribution was carried out with the aid of T-Scan device (Tekscan Inc., South Boston, MA, USA). The first record was recorded before denture relining and the second record was three months after denture relining
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Relining of mandibular dentures was performed by reducing one mm of the denture fitting surfaces and borders to make a right-angled border. apply two separate layers of Mucopren adhesive upon the vestibular surface of the mandibular denture and allow each layer to dry for about 40 seconds. then, the lower denture was inserted and molded in patient mouths; while biting in centric occlusion with the opposing maxillary complete dentures.
Time frame: for each participant: the complete denture should be worn for three months
Fifty completey edentulous patients having previously constructed and utilized conventional complete dentures were selected for this study. Relining of mandibular complete dentures with soft denture liner was carried out. Distribution of occlusal force was evaluated with the aid of T-Scan device before denture relining and three months after relining.
measured before relining of complete denture with soft liner and measured again after complete denture relining.
National Research Centre, Egypt
Other
Effect of Mandibular Complete Dentures Relining on Occlusal Force Distribution Using T- Scan System (A Cross-over Clinical Study)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05737290
Bites and Stings, Chemically-Induced Disorders
Cairo, Nasr City, Egypt
View Trial DetailsNCT07105410
Behavior, Bites and Stings
Lisbon, Portugal
View Trial DetailsNCT06343454
Bites and Stings, Chemically-Induced Disorders
Ankara, Turkey (Türkiye)
View Trial DetailsNCT03332264
Bites and Stings, Chemically-Induced Disorders
Graz, Austria
View Trial Details