Skip to main content
OpenTrials
Completed

NCT Number: NCT06838091

Effect of Low-Flow Anesthesia in Single Lung Ventilation on Postoperative Respiratory Complications

Mechanical ventilation in thoracic surgery patients is often complicated because patients are usually in the lateral decubitus position and the operated lung is intermittently deflated to facilitate surgical exposure . Single-lung ventilation during thoracic surgery is prone to volutrauma, barotrauma, atelectrauma, and oxygen toxicity, which are important aspects of ventilator-associated lung injury (VILI) . In studies conducted on operated patients, the use of lung-protective ventilation, including low tidal volume (6-8 ml/kg), respiratory rate, driving pressure (DP), and positive end-expiratory pressure (PEEP) application, has been recommended in the perioperative period to reduce postoperative pulmonary complications. Optimum oxygenation should be provided to patients during the intraoperative period, avoiding the harmful effects of hypoxia and hyperoxia. This situation becomes even more important in single-lung ventilation. Fresh gas flow in anesthesia systems can be done with traditional high-flow, normal-flow, or low-flow strategies according to the clinician's preference. The interest in the anesthesia method with low fresh gas flow has increased all over the world and in our country. The development of the technology of the anesthesia devices used, the increase in knowledge about the content of inhaled gases, and the availability of monitors that continuously and thoroughly analyze the anesthetic gas composition have facilitated the use of low-flow anesthesia safely.

When the literature is evaluated, it is defined as 4 lt/min and above as very high flow, 2-4 lt/min as high flow, 1-2 lt/min as medium flow, 0.5-1 lt/min as low flow, 0.25-0.5 lt/min as minimal flow, and <0.25 lt/min as metabolic flow . High flow has now been abandoned due to both cost and environmental pollution.

Low-flow anesthesia creates a breath air closer to physiological conditions during anesthesia by heating and humidifying the inhaled gases. In addition, it provides a cost advantage by reducing inhalation agent consumption and reduces atmospheric pollution . It is suggested that the use of both fresh gas flow rates does not pose a safety risk for patients, and in fact, the use of low-flow anesthesia methods should be made more widespread with the advantages it provides. Low-flow anesthesia is a method applied during general anesthesia using a rebreathing anesthesia system, where the rebreathed fresh oxygen flow rate is at least 50%, metabolic requirements are fully met and sufficient volatile matter can be administered. In our clinic, the fresh gas flow rate during general anesthesia is routinely used at a value between 0.5 lt/min-3 lt/min, depending on the clinician's preference. In our clinic, low-flow anesthesia methods (with varying flows) are routinely applied in addition to normal flow methods in many surgical practices.

Although low-flow anesthesia techniques are used in many surgical practices, the literature is limited in surgeries where single-lung ventilation is performed. The purpose of this study is to determine the anesthetic flows used in amounts ranging from 0.5 lt/min-3 lt/min in thoracic surgeries where single-lung ventilation is performed; to evaluate the effects on perioperative hemodynamic and respiratory parameters and respiratory complications. The secondary aim of the study is to show the consumption of inhalation agent and soda lime.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–75 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Başakşehir Çam Ve Sakura Şehir Hastanesi

Istanbul, İ̇stanbul, 34480, Turkey (Türkiye)

About this study

Mechanical ventilation in thoracic surgery patients is often complicated because patients are usually in the lateral decubitus position and the operated lung is intermittently deflated to facilitate surgical exposure. Single-lung ventilation during thoracic surgery is prone to volutrauma, barotrauma, atelectrauma, and oxygen toxicity, which are important aspects of ventilator-associated lung injury (VILI). In studies conducted on operated patients, the use of lung-protective ventilation, including low tidal volume (6-8 ml/kg), respiratory rate, driving pressure (DP), and positive end-expiratory pressure (PEEP) application, has been recommended in the perioperative period to reduce postoperative pulmonary complications. Optimum oxygenation should be provided to patients during the intraoperative period, avoiding the harmful effects of hypoxia and hyperoxia. This situation becomes even more important in single-lung ventilation. Fresh gas flow in anesthesia systems can be done with traditional high-flow, normal-flow, or low-flow strategies according to the clinician's preference. The interest in the anesthesia method with low fresh gas flow has increased all over the world and in our country. The development of the technology of the anesthesia devices used, the increase in knowledge about the content of inhaled gases, and the availability of monitors that continuously and thoroughly analyze the anesthetic gas composition have facilitated the use of low-flow anesthesia safely.

When the literature is evaluated, it is defined as 4 lt/min and above as very high flow, 2-4 lt/min as high flow, 1-2 lt/min as medium flow, 0.5-1 lt/min as low flow, 0.25-0.5 lt/min as minimal flow, and <0.25 lt/min as metabolic flow. High flow has now been abandoned due to both cost and environmental pollution.

Low-flow anesthesia creates a breath air closer to physiological conditions during anesthesia by heating and humidifying the inhaled gases. In addition, it provides a cost advantage by reducing inhalation agent consumption and reduces atmospheric pollution. It is suggested that the use of both fresh gas flow rates does not pose a safety risk for patients, and in fact, the use of low-flow anesthesia methods should be made more widespread with the advantages it provides. Low-flow anesthesia is a method applied during general anesthesia using a rebreathing anesthesia system, where the rebreathed fresh oxygen flow rate is at least 50%, metabolic requirements are fully met and sufficient volatile matter can be administered. In our clinic, the fresh gas flow rate during general anesthesia is routinely used at a value between 0.5 lt/min-3 lt/min, depending on the clinician's preference. In our clinic, low-flow anesthesia methods (with varying flows) are routinely applied in addition to normal flow methods in many surgical practices.

Although low-flow anesthesia techniques are used in many surgical practices, the literature is limited in surgeries where single-lung ventilation is performed. The purpose of this study is to determine the anesthetic flows used in amounts ranging from 0.5 lt/min-3 lt/min in thoracic surgeries where single-lung ventilation is performed; to evaluate the effects on perioperative hemodynamic and respiratory parameters and respiratory complications. The secondary aim of the study is to show the consumption of inhalation agent and soda lime.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients who will undergo thoracic surgery with single lung ventilation
  • ASA I-II-III class
  • 18-75 years old
  • Those who have received informed consent form approval

Exclusion criteria

  • COPD and asthma diagnosis
  • History of previous thoracic surgery
  • Body mass index (BMI) >35
  • Development of hemodynamic instability or desaturation during surgery (SpO2<92)

Treatment and study plan

Observational

Other

During anesthesia administration:

T0, T1, T2, T3, T4 represent the following periods:

T0: Double lumen ventilation in the supine position immediately after intubation T1: Double lumen ventilation in the lateral position T2: Single lumen ventilation in the lateral position (with the chest wall closed) T3: Single lumen ventilation in the lateral position (with the chest wall open) T4: Just before extubation

  • Airway pressure (P plateau, Ppeak) values from the anesthesia device data,
  • BIS (from routine BIS monitoring)
  • Temperature (Routinely from pharyngeal temperature probe),
  • Oxygen saturation (Routinely from the patient monitor)
  • End-tidal CO₂,
  • Inspiratory O₂ concentration,
  • Inspiratory CO2 concentration,
  • Inspiratory and expiratory desflurane/sevoflurane concentrations,
  • Tidal volume,
  • MAC, routinely from anesthesia device data
  • Blood Gas Analysis (COHgb, Ph, PO 2 , PCO 2 , SaO 2, HCO 3 , Base deficit, glucose, lactate)

Primary outcomes

  1. The effects of anesthetic flows varying

    Time frame: 01.03.2025- 01.06.2025

    Primary outcome is the effects of anesthetic flows varying between 0.5 lt/min-3 lt/min on perioperative hemodynamic and respiratory parameters and respiratory complications in thoracic surgeries with single lung ventilation.

Sponsors and collaborators

Lead sponsor

Başakşehir Çam & Sakura City Hospital

Other Gov

Registry information

Acronym: Low-Flow Anest

Important dates

Study start
2025
Primary completion
2025
Study completion
2025
First posted
Feb 20, 2025
Registry last updated
May 7, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.