Completed

NCT Number: NCT07628491

Effect of Finishing Clear Aligner Marginal Termination Design (Supragingival vs Juxtagingival) on Aligner Color Stability After 14 Days of Wear: A Split-Mouth Study

* The goal of this clinical study is to learn whether the gumline edge design of a finishing orthodontic clear aligner affects how much the aligner's color changes after 14 days of wear. * The main question is: does a supragingival edge design - a straight edge covering about 2 mm of gum tissue - lead to a different amount of color change in the aligner compared with a juxtagingival edge design that follows the gumline exactly, after 14 days of wear? * Each participant wears finishing clear aligners with both edge designs at the same time - one design on the upper jaw and the other on the lower jaw - and serves as their own comparison (split-mouth). This within-person approach removes differences between individuals in oral hygiene, diet, and saliva. * The aligner's color over six selected teeth (three upper, three lower) is measured with a dental spectrophotometer (VITA Easyshade V) at placement (day 0) and after 14 days. Each measurement is repeated three times under standardized optical conditions. The amount of color change is expressed as a color-difference value (ΔE). * The study hypothesis is that marginal termination design (supragingival versus juxtagingival) is associated with a difference in the 14-day colorimetric change (ΔE00) of the finishing aligner. * The study is carried out during the finishing (refinement) stage of orthodontic treatment, when only small residual tooth movements remain, so that color changes can be attributed to wear and edge design rather than to tooth movement.

Completed

Looking for future studies?

Notify Me

Key information

Age range

15 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Aorys Clinic

Sibiu, Sibiu County, 550118, Romania

About this study

  • BACKGROUND AND RATIONALE
  • Two trimming-line (edge) designs are commonly used during the finishing (refinement) stage of clear aligner therapy. The supragingival design uses a straight edge positioned approximately 2 mm apical to the free gingival margin, covering approximately 2 mm of gingival tissue. The juxtagingival festooned design follows the natural scalloped contour of the free gingival margin, without covering gingival tissue. Color stability of the aligner during wear is relevant to esthetics and patient acceptance. Whether marginal termination design influences the colorimetric stability of the aligner during wear has not been investigated.
  • STUDY DESIGN
  • This is a prospective, within-person (split-mouth) interventional study. Each participant receives both designs simultaneously: the supragingival design on one dental arch and the juxtagingival festooned design on the contralateral arch. The split-mouth design controls for inter-individual variation in oral hygiene, diet, and salivary composition. The aligner material (CA Pro tri-layer, SCHEU-DENTAL GmbH, Iserlohn, Germany; CE-marked thermoplastic) is identical for both designs; only the marginal termination geometry differs.
  • ALLOCATION RULE (NON-RANDOMIZED)
  • Allocation follows a pre-specified hierarchical rule documented prior to enrollment. Primary criterion: the dental arch with the greater magnitude of planned dental intrusion (mm, from the digital treatment setup) receives the supragingival design. Tiebreaker (equal or zero planned intrusion on both arches): a pre-specified systematic alternating sequence in enrollment order. Planned intrusion magnitude per arch is recorded as a covariate.
  • TARGET TEETH AND MEASUREMENT
  • Colorimetric measurements of the aligner are performed extraorally at six target-tooth positions per participant: three maxillary (1.4, 1.1, 2.3) and three mandibular (4.3, 3.1, 3.4). Measurements are obtained with a dental spectrophotometer (VITA Easyshade V) operated in Custom Color mode, which simultaneously displays the CIE L, a, and b color coordinates. To ensure reproducibility, the aligner is measured under standardized optical conditions using a standardized optical substrate and a fixed positioning reference (methodological details reported separately). Each target position is measured in triplicate at each visit.
  • VISITS
  • Measurements are obtained at T0 (day 0, at placement of the finishing aligner) and T1 (day 14 ± 2 of wear), yielding 36 L, a, b measurements per participant (6 positions × 3 repetitions × 2 visits).
  • OUTCOME
  • The primary outcome is the colorimetric change (ΔE00, CIEDE2000) of the aligner between T0 and T1, computed per dental arch from the measured L, a, b coordinates, compared between the supragingival-design arch and the juxtagingival-design arch. The CIELAB ΔEab value is reported descriptively for comparability with prior literature.
  • STUDY CONTEXT
  • The study is conducted during the finishing (refinement) stage, when only small residual tooth movements remain, so that observed color changes can be attributed to wear and marginal termination design rather than to substantial tooth movement.
  • RELATIONSHIP TO COMPANION STUDY
  • A subset of participants may be concurrently enrolled in the companion study PATHO-ALIGN (ClinicalTrials.gov NCT07533058), a split-mouth study of finishing-aligner marginal termination design and subgingival periodontal microbiota conducted by the same investigator at the same sites. Co-enrolled participants wear the same finishing clear aligners with the same arch-level marginal-design allocation in both studies; the present study adds only a non-invasive, extraoral colorimetric assessment of the aligners and does not interfere with the companion study. The two studies have distinct outcomes.
  • STATISTICAL ANALYSIS
  • Primary confirmatory analysis: The confirmatory endpoint is the arch-level aligner color change (ΔE00) between T0 and T1. The supragingival-design arch and the juxtagingival-design arch are compared within participants using a paired test (two-sided, alpha = 0.05). Normality of the paired differences is assessed (Shapiro-Wilk); a paired t-test is used if the assumption holds, otherwise the Wilcoxon signed-rank test. A single confirmatory comparison is pre-specified, controlling the type I error rate without multiplicity correction.
  • Adjusted analysis: A linear mixed-effects model is fitted to arch-level ΔE00, with marginal termination design (supragingival vs juxtagingival), dental arch (maxillary vs mandibular), planned intrusion magnitude per arch, and self-reported daily wear time as fixed effects, and a participant-level random intercept to account for the paired (split-mouth) structure. Including dental arch as a covariate separates a potential arch-level effect from the design effect.
  • Secondary analyses (descriptive): Component color changes (ΔL, Δa, Δb) per arch between T0 and T1; overall aligner color change across all target positions (ΔE00 and ΔEab); and the proportion of arch-level changes exceeding the Paravina (2015) perceptibility (ΔE00 = 0.8) and acceptability (ΔE00 = 1.8) thresholds.
  • Measurement reliability: Intra-position reproducibility across the three repeated measurements is quantified using the intraclass correlation coefficient (ICC).
  • Missing data and quality control: Repeated measurements failing pre-specified inter-repetition agreement criteria are excluded, and the mean of the remaining repetitions is used; analyses use available per-protocol data.
  • SAMPLE SIZE JUSTIFICATION
  • Sample size was determined for a paired within-subject (split-mouth) comparison of arch-level aligner color change (ΔE00). In the absence of prior data specific to marginal termination design effects on aligner color, parameters were selected conservatively: a minimum meaningful between-arch difference of ΔE00 = 0.8 (50:50% perceptibility threshold; Paravina 2015), an assumed standard deviation of paired differences of approximately 0.9 (derived from an assumed arch-level standard deviation with an intra-subject correlation rho = 0.4), and a two-sided alpha = 0.05 (paired test). Under these assumptions, 50 participants provide power exceeding 90% to detect the specified difference and remain adequately powered (approximately 85%) for smaller between-arch differences (ΔE00 ≈ 0.4). The enrolled sample (50 participants; 100 aligners, two per participant) also serves to estimate within-subject colorimetric variability to refine power assumptions for subsequent confirmatory studies.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adolescent and adult patients (age 15 years or older at enrollment)
  • Undergoing a finishing (refinement) stage of clear aligner therapy, with only small residual tooth movements remaining, including both patients completing active orthodontic treatment and patients with prior orthodontic treatment who require additional refinement (e.g., minor relapse or loss of retention)
  • Adherence to the prescribed oral hygiene instructions
  • Written informed consent; for participants aged 15-17 years, written consent from a parent or legal guardian

Exclusion criteria

  • Deficient oral hygiene
  • Excessive consumption of intensely staining beverages (coffee, tea, red wine, colored carbonated drinks)
  • Systemic conditions or medications that may affect salivary secretion or tooth color
  • Non-compliance with the aligner / orthodontic appliance wear protocol

Treatment and study plan

Tri-layer thermoplastic finishing clear aligner

Device

Finishing clear aligner fabricated from CA Pro tri-layer thermoplastic (SCHEU-DENTAL GmbH, Iserlohn, Germany; CE-marked), fabricated by SC APARAT DENTAR SRL, Sibiu, Romania. Each participant receives aligners with both trimming-line designs simultaneously - supragingival on one arch and juxtagingival festooned on the contralateral arch. Material and thickness are identical for both designs; only trimming-line geometry differs. (Cross-referenced to both arms.)

Primary outcomes

  1. Aligner Color Change (ΔE00) After 14 Days of Wear

    Time frame: Day 0 and day 14

    Mean color change (ΔE00, CIEDE2000) of the finishing aligner between day 0 and day 14, per dental arch, computed from CIE L*, a*, b* coordinates averaged over three target positions measured in triplicate. The supragingival-design arch and the juxtagingival-design arch are compared within each participant (paired split-mouth).

Secondary outcomes

  1. Component Color Changes (ΔL*, Δa*, Δb*)

    Time frame: Day 0 and day 14

    Mean changes in the individual CIE coordinates per arch between day 0 and day 14, characterizing the direction of color change (lightness; red-green; yellow-blue axes).

  2. Overall Aligner Color Change (ΔE00 and ΔE*ab, pooled)

    Time frame: Day 0 and day 14

    Color change of the finishing aligner across all target positions regardless of marginal termination design, reported as ΔE00 (CIEDE2000) and, for comparability with prior literature, ΔE*ab (CIELAB), characterizing overall colorimetric stability during wear.

Other outcomes

  1. Proportion of Measurements Exceeding Perceptibility / Acceptability Thresholds

    Time frame: Day 0 and day 14

    Proportion of arch-level color changes exceeding the 50:50% perceptibility (ΔE00 = 0.8) and acceptability (ΔE00 = 1.8) thresholds (Paravina 2015). Interpreted descriptively; these thresholds were established for permanent restorations compared with adjacent teeth and are used here only as a reference standard, not as a clinical failure criterion for a temporary 14-day aligner.

Sponsors and collaborators

Lead sponsor

George Emil Palade University of Medicine, Pharmacy, Sciences and Technology of Targu Mures

Other

Collaborators

  • Aorys Clinic, Sibiu, Romania
  • SC APARAT DENTAR SRL, Sibiu, Romania

Registry information

Official study title

Colorimetric Stability of Finishing Clear Aligners According to Marginal Termination Design (Supragingival Versus Juxtagingival) After 14 Days of Intraoral Wear During Orthodontic Treatment: A Prospective Split-Mouth Study

Acronym: SPECTRO-ALIGN

Important dates

Study start
2026
Primary completion
2026
Study completion
2026
First posted
Jun 5, 2026
Registry last updated
Jul 24, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.