Acute respiratory syndrome distress (ARDS) is a clinical common syndrome with high mortality. Mechanical ventilation (MV) is the cornerstone of management of ARDS but can lead to ventilator-induced lung injury. Positive end-expiratory pressure (PEEP), as one of main component of MV, has been widely used in the clinical practice. However, how to best set PEEP is still a difficult problem for moderate to severe ARDS patients. EIT, an imaging tool evaluating the regional ventilation distribution at the bedside, can achieve the individual PEEP selection for all mechanically ventilated patients. This article compared the effect of PEEP titrated guided by EIT with fraction of inspired oxygen (FiO2)-PEEP table on the ventilation-perfusion mismatch.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Nanjing, Jiangsu, 210009, China
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Electric impedance tomography-guided PEEP titration
Time frame: up to 24 hours
EIT-PEEP was obtained by EIT, low-PEEP was obtained by low FIO2-PEEP table, and high-PEEP was obtained by high FIO2-PEEP table.
Time frame: up to 24 hours
COV was obtained by EIT monitoring
Time frame: up to 24 hours
dead space was obtained by EIT monitoring
Time frame: up to 24 hours
shunt was obtained by EIT monitoring
Time frame: up to 24 hours
wasted ventilation was obtained by EIT monitoring
Time frame: up to 24 hours
wasted perfusion was obtained by EIT monitoring
Time frame: up to 24 hours
ventilation distribution was obtained by EIT in difference regions
Time frame: up to 24 hours
perfusion distribution was obtained by EIT in difference regions
Time frame: up to 24 hours
Overdistension (%) and lung collapses (%) will be assessed by EIT. These two values cannot be measured separately. V/Q mismatch will be computed by EIT, and expressed in %. Correlation will be performed by linear regression.
Time frame: up to 24 hours
recruitment-to-inflation (R/I) ratio was computed between the two PEEP levels
Time frame: up to 24 hours
PaO2/FIO2 was obtained by gas analysis
Time frame: up to 24 hours
respiratory system compliance included lung compliance, chest wall compliance, and respiratory system compliance. respiratory system resistance will be computed as the inverse of compliance.
Time frame: up to 24 hours
Recruitability will be assessed between 15 and 5 cmH2O by respiratory mechanics, as the recruited volumes value (in mL). R/I ratio will be derived from these data (no unit). V/Q mismatch will be computed by EIT, and expressed in %. Correlation will be performed by linear regression.
Southeast University, China
Other
Effect of Electric Impedance Tomography-Guided PEEP Titration on the Ventilation-perfusion Mismatch in Moderate or Severe ARDS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05074758
ARDS, Human, COVID-19 Acute Respiratory Distress Syndrome
Paris, France
View Trial DetailsNCT04444609
ARDS, Human, COVID-19
London, United Kingdom
View Trial DetailsNCT05148026
ARDS, Human, Acute Kidney Injury
Monza, Italy
View Trial DetailsNCT04447833
ARDS, Human, COVID
Uppsala, Sweden
View Trial Details