Intermittent Oro-esophageal Tube Feeding
DeviceThe observation group was given enteral nutritional support with Intermittent Oro-esophageal Tube Feeding according to the following procedure: Before each feeding, inside and outside of the tube was cleaned with water. During feeding, the patient should maintain a semi-reclining or sitting position with mouth opened, and the tube was inserted slowly and smoothly into the upper part of the esophagus by medical staffs while the appropriate depth of intubation was checked with the calibration markings on the tube wall. The distance from the incisors to the head part of the tube should be between 22-25 cm. However, the specific depth should be evaluated based on patients' feedback and adjusted accordingly. After insertion, the tail part of the tube should be put into a container full of water and the absence of continuous bubbles indicated a successful intubation. Then, the feeding was to be conducted three times per day with 50 ml per minute and 400-600ml for each feeding.