NCT Number: NCT06369090

Effect of Breast Size on the Electrical Impedance Tomography Measurement

Twenty-two healthy female volunteers were monitored using electrical impedance tomogprahy (EIT) in two different situations. First, with electrode belt placed over the breast tissue and second, with the electrode belt under the breast tissue. The EIT measurement was performed with adjunct spirometric measurement. The changes of regional ventilation related to the breast tissue and the size of breast tissue were evaluated.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–50 year

Sex eligibility

Female

Study type

Interventional

Phase

Not applicable

Primary location

Faculty of Biomedical Engineering, Czech Technical University in Prague

Kladno, 27201, Czechia

About this study

The EIT measurement (PulmoVista 500, Dräger Medical, Germany) was performed in supine lying position. On every subject, an electrode belt of proper size based on the measured thorax circumference was placed. It was crucial to find a right position where it was possible to place the electrode belt over the breast tissue and then underneath the breast tissue, without changing the level and the position of the electrode belt on the thorax. Also, the position of the belt had to be between 4th and 6th intercostal space, as recommended by the manufacturer. The change of the position of the belt relative to the breast tissue was performed in a lying position by a slight pull of the buckled belt away from the subject´s body, so the subject could relocate the breast tissue over the belt using her own hands into the position as desired by the researcher.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • healthy female volunteers

Exclusion criteria

  • morbid obesity
  • standard exclusion criteria for electrical impedance tomography according to the manufacturer

Treatment and study plan

Electrical impedance tomography (EIT)

Device

Non-invasive, radiation-free bedside lung monitoring using small alternating currents with no known side effects.

Primary outcomes

  1. Regional ventilation changes possibly caused by the breast tissue

    Time frame: 30 minutes

    The dependence of the regional ventilation evaluated by EIT on the breast size on the regional ventilation was not confirmed.

Secondary outcomes

  1. Female subjects enrollment in EIT studies and clinical applications

    Time frame: 30 minutes

    Recommendation to include women in studies and clinical applications that use electrical impedance tomography for lung monitoring

Sponsors and collaborators

Lead sponsor

Czech Technical University in Prague

Other

Registry information

Official study title

Effect of Women Breast Size on Lung Monitoring Using Electrical Impedance Tomography

Important dates

Study start
2013
Primary completion
2014
Study completion
2014
First posted
Apr 16, 2024
Registry last updated
Apr 16, 2024