The University of Texas Health Science Center at Houston
Houston, Texas, 77030, United States
NCT Number: NCT06107335
The purpose of this study is to compare the effect of albumin versus routine care on hemodynamic response and stability in pre-eclamptic patients during cesarean delivery. The hypothesis is that volume replacement with albumin guided by stroke volume variation (SVV) using a ClearSight-Acumen (CS-A) monitor, before cesarean delivery (CD), improves hemodynamic stability in preeclamptic patients with severe features compared to routine care, under neuraxial anesthesia.
Trial opening soon.
Get Notified18 year and older
Female
Interventional
Phase 4
Houston, Texas, 77030, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Fluid replacement will be achieved with colloid (5% albumin infusion). A bolus infusion of up to 500 milliliters (mL) of 5% Albumin will be administered prior to the placement of neuraxial anesthesia. If stroke volume variation (SVV) drops to less than 13% during the infusion of albumin, the infusion will be halted. At the completion of the placement of the spinal/combined spinal-epidural (CSE) anesthesia, study participants will receive the remaining albumin infusion if it was initially halted and SVV increases back to >13% during the procedure (to a total maximum of 500 mL albumin for the entire procedure).
Other names: Albutein
Fluid restriction will be achieved with crystalloid (lactated ringer's injection) administered at a keep-the-vein-open (KVO) rate of 75 milliliters per hour (mL/hr), administered during the procedure.
Use of colloid will be guided by stroke volume variation (SVV) as assessed by the Edwards HemoSphere monitor with ClearSight-Acumen finger cuff device. The Edwards HemoSphere monitor with ClearSight-Acumen (CSA) finger cuff is a hemodynamic monitoring system that obtains continuous blood pressure readings from a cuff on the finger. In study participants, the finger cuff will be placed on the middle finger of one of the hands. The Edwards device can be used to predict impending intraoperative hypotension before its occurrence. The device has the ability to assess vasodilatory status using systemic vascular resistance (SVR), volume status using stroke volume variation (SVV) and stroke volume (SV) and the use of Carbon Monoxide (CO) to assess for underlying cardiac suppression. It also incorporates the hypotension prediction index (HPI), an algorithm that uses the arterial waveform to predict early phases of intraoperative hypotension.
Time frame: from baseline to thirty minutes after arrival to the Post Anesthesia Care Unit (PACU)
"Fluid responsiveness" (in other words, a "positive response") is defined as a volume-induced correction to stroke volume variation (SVV) values < 13%. SVV measurements will be made using the Edwards HemoSphere monitor with ClearSight-Acumen finger cuff.
Time frame: from baseline to thirty minutes after arrival to the Post Anesthesia Care Unit (PACU)
Time frame: baseline, after infusion of study intervention, at completion of placement of the spinal/CSE anesthesia, at completion of delivery of the baby, at end of procedure when leave operating room, thirty minutes after arrival to PACU
Time frame: baseline, after infusion of study intervention, at completion of placement of the spinal/CSE anesthesia, at completion of delivery of the baby, at end of procedure when leave operating room, thirty minutes after arrival to PACU
Time frame: from start of operation to thirty minutes after arrival to the Post Anesthesia Care Unit (PACU)
Time frame: from start of operation to discharge from the Post Anesthesia Care Unit (PACU)
Contact information is provided by the study sponsor or research team.
The University of Texas Health Science Center, Houston
Other
Effect of Albumin Versus Routine Care on Hemodynamic Response and Stability in Patients With Preeclampsia Guided by a Non-invasive Hemodynamic Monitoring System During Cesarean Delivery With Spinal Anesthesia - A Randomized Controlled Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07695909
Female Urogenital Diseases and Pregnancy Complications, Hypertension, Pregnancy-Induced
New York, United States
View Trial DetailsNCT07072052
Female Urogenital Diseases and Pregnancy Complications, Hypertension, Pregnancy-Induced
Oxford, United Kingdom
View Trial DetailsNCT06387784
Female Urogenital Diseases and Pregnancy Complications, Hypertension, Pregnancy-Induced
Ribeirão Preto, São Paulo, Brazil
View Trial DetailsNCT07458997
AI Chatbot for Prenatal Nutrition Guidance, Diabetes Mellitus
Hong Kong
View Trial Details