Leipzig Heart Center
Leipzig, Saxony, 04289, Germany
NCT Number: NCT02672553
The study purpose is to compare the EDWARDS INTUITY valve system in a minimal invasive surgical approach (MIS) with any commercially available aortic bioprosthesis in standard full sternotomy surgical approach.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Leipzig, Saxony, 04289, Germany
This is a randomized study to compare the cross-clamp time (XCT) and cardiopulmonary bypass time (CPBT) of the EDWARDS INTUITY valve system in a minimally invasive surgical approach (MIS) with any commercially available aortic bioprosthesis in standard full sternotomy surgical approach, in patients with logistic EuroScore < 20 undergoing elective isolated aortic valve replacement (AVR) surgery.
Additionally, the aim is to gather sufficient data to quantify the effect size of short term patient benefit outcomes previously identified from literature and to explore additional healthcare resource utilization endpoints.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion:
Exclusion (i.a.):
≤ 1 month before the intended treatment
Intra-operative Exclusion:
To evaluate cardiac performance characteristics and adverse events rates associated with the EDWARDS INTUITY Valve in patients undergoing MIS-AVR.
Other names: aortic stenosis, stenosis-based insufficiency, aortic valve replacement
In comparison to control valves available on the market undergoing FS-AVR
Other names: aortic stenosis, stenosis-based insufficiency, aortic valve replacement
Time frame: At time of surgery; an average of 1 hour
Cardiopulmonary cross clamp time is the amount of time that the patient's aorta (blood vessel) is clamped by a surgical instrument used in cardiac surgery. This allows the normal blood flow to be sent to an artificial heart and lung machine to keep it at a constant temperature and oxygen level.
Time frame: At time of surgery; an average of 1 hour
Cardiopulmonary bypass time is the amount of time that the patient's blood circulates through an artificial heart and lung machine during cardiac surgery.
Time frame: Baseline and 2 Years.
The New York Heart Association (NYHA) functional classification system relates symptoms to everyday activities and the patient's quality of life.
Class I. Patients with cardiac disease but without resulting limitation of physical activity.
Class II. Patients with cardiac disease resulting in slight limitation of physical activity. They are comfortable at rest.
Class III. Patients with cardiac disease resulting in marked limitation of physical activity. They are comfortable at rest.
Class IV. Patients with cardiac disease resulting in inability to carry on any physical activity without discomfort. Symptoms of heart failure or the anginal syndrome may be present even at rest.
Time frame: Baseline, Discharge, 30 days, 3 Months, 1 Year
Mean gradient is the average flow of blood through the aortic valve measured in millimeters of mercury. Gradients are evaluated by echocardiography over time. Mean gradient values depend on the size and type of valve.
Time frame: Baseline, Discharge, 30 days, 3 Months, 1 Year
Peak gradient is the maximum value measured of flow of blood through the aortic valve as measured in millimeters of mercury. Gradients are evaluated by echocardiography over time.
Time frame: Baseline, Discharge, 30 days, 3 Months, 1 Year
Effective orifice area represents the cross-sectional area of the blood flow downstream of the aortic valve. Effective orifice area is evaluated by echocardiography over time.
Time frame: Discharge, 30 days, 3 month, 1 year
Number of subjects who experienced a Paravalvular Leak shown over various time points.
Paravalvular leak refers to blood flowing through a channel between the implanted artificial valve and the cardiac tissue as a result of inappropriate sealing.
Paravalvular leak is evaluated by echocardiography over time. It is assessed on a scale from minimum of 0 to maximum of 4, where 0 = no leak, 1 = a trace leak, 2 = a mild leak, 3 = a moderate leak, and 4 = a severe leak.
Higher numbers on the scale show a worsening outcome.
Time frame: Prior to Surgery
Subjects randomized to the Edwards INTUITY group that were converted to the control group and received commercially available surgical aortic heart valves during surgery.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of Subjects who had a surgical opening of their chest after their initial aortic heart valve surgery shown over various time points.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of Subjects who received a Permanent Pacemaker shown over various time points.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Paravalvular Leak shown over various time points.
Paravalvular leak refers to blood flowing through a channel between the implanted artificial valve and the cardiac tissue as a result of inappropriate sealing.
Paravalvular leak is evaluated by echocardiography over time. It is assessed on a scale from 0 to 4, where 0 = no leak, 1 = a trace leak, 2 = a mild leak, 3 = a moderate leak, and 4 = a severe leak.
Higher numbers on the scale show a worsening outcome.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced Major Bleeding shown over various time points.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Respiratory Failure shown over various time points. Respiratory failure happens when not enough oxygen passes from your lungs to your blood.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Cerebral Vascular Accident or Permanent Stroke shown over various time points.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced Renal (kidney) Failure shown over various time points.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced Endocarditis shown over various time points. Endocarditis is an infection of the endocardium, which is the inner lining of your heart chambers and heart valves.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Deep Sternal Wound Infection shown over various time points.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Myocardial Infarction shown over various time points. A Myocardial infarction, commonly known as a heart attack, occurs when blood flow decreases or stops to a part of the heart, causing damage to the heart muscle.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Thromboembolism shown over various time points. A thromboembolism is an obstruction of a blood vessel by a blood clot that has become dislodged from another site in the circulation.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Cardiac Tamponade shown over various time points. Cardiac tamponade is when fluid in the pericardium (the sac around the heart) builds up and results in compression (squeezing) of the heart.
Time frame: 30 days, 3 Months, 1 Year, 2 Years.
Number of subjects who experienced a Cardiac reoperation for any reason shown over various time points.
Time frame: Prior to Surgery
Subjects Randomized to Edwards INTUITY Group's Surgical Aortic Valve undergoing Minimally Invasive Surgical incision being converted to a Full Sternotomy open procedure During Surgery.
Time frame: Baseline, 30 days, 3 Months, 1 Year
The EuroQol-5 Dimension (EQ-5D) is a standardized questionnaire that asks subjects to rate themselves (no problems, some problems, extreme problems) on mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. The scale is indexed and ranges from a minimum of 0.275 and a maximum of 1.000. A lower number indicates the participants experiences more problems and a higher number indicates the participants experiences fewer problems.
Time frame: Baseline, 30 days, 3 Months, 1 Year
Subject's Average Score at Baseline and at each follow-up interval until 2 year - SF-12.
The Medical Outcomes Study Short-Form 12 (SF-12) - Physical Component Summary (PCS) and Mental Component Summary (MCS).
The SF-12 questionnaire scale ranges from 100, which reflects the best health status to 0, which reflects the worse health status.
Time frame: Baseline, 30 days, 3 Months, 1 Year
The Kansas City Cardiomyopathy Questionnaire (KCCQ) is a 23-item, self-administered instrument that quantifies physical function, symptoms (frequency, severity and recent change), social function, self-efficacy and knowledge, and quality of life. Scores range from 0-100, in which higher scores reflect better health status. Subjects took this questionnaire at Baseline, 30 days, 3 Months,and 1 Year.
Time frame: Day of surgical procedure through discharge from the hospital, an average of 1.5 weeks
The average amount of time the subjects spent in the intensive care unit, the intermediate care length of stay, and the average total length of hospital stay after their heart valve replacement procedure.
Time frame: Baseline, Discharge, 30 days, 3 Months, 1 Year
Effective orifice area index represents the minimal cross-sectional area of the blood flow downstream of the aortic valve divided by the person's body surface area. Effective orifice area index is evaluated by echocardiography over time.
Time frame: Discharge, 30 days, 3 month, 1 year
Aortic valvular regurgitation occurs when the aortic valve in the heart does not close tightly allowing some of the blood that was pumped out of the heart to leak back into it. Aortic valvular regurgitation is evaluated by echocardiography over time. It is assessed on a scale from 0 to 4, where 0 represents no regurgitation and 4 represents severe regurgitation.
Higher numbers on the scale show a worsening outcome.
Edwards Lifesciences
Industry
A Randomized Comparison of the EDWARDS INTUITY Valve System anD commErcially Available Aortic Bioprostheses in Subjects uNdergoing surgiCal Aortic Valve Replacement Using Minimally InvaSive Techniques
Acronym: CADENCE-MIS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02338154
Aortic Stenosis, Aortic Valve Disease
Salzburg, Austria
View Trial DetailsNCT02688153
Aortic Stenosis, Aortic Valve Disease
Pessac, France
View Trial DetailsNCT07276711
Aortic Stenosis, Aortic Valve Disease
New Orleans, Louisiana, United States
View Trial DetailsNCT04437303
Aortic Valve Disease, Aortic Valve Stenosis
Aalst, Belgium
View Trial Details