NCT Number: NCT01532921
EASE TRICUSPID Expertise-based Assessment Study on Clinical Efficacy of Contour 3D® in TRICUSPID Valve Annuloplasty
Few clinical evidence for the Contour 3D Tricuspid Annuloplasty Ring exists; therefore, in order to position this product on the market, a post-market release study was completed. The purpose of this study was to evaluate the hemodynamic performance of the Contour 3D® Tricuspid Annuloplasty Ring following Tricuspid Valve (TV) repair in a post-market environment.
Looking for future studies?
Notify MeKey information
Conditions
Age range
18 year–85 year
Sex eligibility
All sexes
Study type
Observational
Primary location
Hôpital de Lyon - Hôpital Louis Pradel, Lyon, France
About this study
The EASE TRICUSPID Clinical Trial was a prospective, non-randomized, non-interventional, post-market release study. The purpose of this study was to evaluate the hemodynamic performance of the Contour 3D® Tricuspid Annuloplasty Ring following Tricuspid Valve (TV) repair in a post-market environment. Therefore, the primary objective of the EASE Tricuspid Study was to evaluate the hemodynamic performance of the Contour 3D® Tricuspid Annuloplasty Ring (Contour 3D ring) in subjects with tricuspid regurgitation who had a clinical indication for TV repair in a post-market use. Secondary objectives included the evaluation of the effect of TV repair with the Contour 3D ring on the right ventricular function, as well as the assessment of the effect of TV repair with the Contour 3D ring on the functional status in subjects undergoing TV repair in a post-market environment. Subjects eligible for TV repair and compliant with the enrollment criteria were considered by the Investigator for inclusion in the study. To minimize bias, enrolled subjects were followed by their own physician in accordance with the center's established practice for routine follow up. Follow-up sessions were planned at the physician's discretion. To meet the intended goals, appropriate clinical data were collected at baseline (pre-surgery), during the surgical procedure, at discharge and during the follow-up period at 6 months. Experienced echo-cardiologists evaluated the echos. At the time of enrollment it was not certain if the subject would receive a Contour 3D ring, since the surgeon might have decided during surgery that another treatment was more beneficial to the subject. In this case, the subject was terminated from the study.
Who can participate
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
- Willing to sign and date the Patient Informed Consent (PIC)
- Indicated for a concomitant surgical repair of the TV
- Willing to return to the hospital, where the implantation originally occurred, for a 6 month follow-up visit
Exclusion criteria
- Patients with a degenerative TV condition
- Patients with primary TV regurgitation
- Previous TV repair or replacement
- Stand-alone TV repair
- Already participating in another investigational device or drug study, possibly leading to bias and jeopardizing the scientific appropriate assessment of the study endpoints
- Life expectancy of less than one year
- Pregnant or desire to be pregnant within 12 months of the study treatment
- Under 18 years or over 85 years of age
- Patients with active endocarditis
- Patients with valvular retraction with severely reduced mobility
- Patients with a heavily calcified TV
Treatment and study plan
Left-sided heart surgery
ProcedureTricuspid valve repair was with the study device was only warranted if concomitant left-sided heart surgery was planned
Contour 3D Tricuspid Annuloplasty Ring
DeviceContour 3D Tricuspid Annuloplasty procedure was used during the tricuspid valve repair
Primary outcomes
-
Mean Gradient Across the Tricuspid Valve
Time frame: At Baseline, Discharge (up to 5 days post-implant) and 6 months post-implant
The mean gradient across the Tricuspid Valve (TV) measured via echocardiography at discharge (up to 5 days post-implant) through 6 months post-implant
-
Change in the Degree of Tricuspid Regurgitation From Baseline Through Discharge (up to 5 Days Post-implant) and 6 Months Post-implant
Time frame: Baseline to Discharge (up to 5 days post-implant) and through 6 months post-implant
Change in the degree of tricuspid regurgitation measured via echocardiography from Baseline through 6 months post-implant. The severity of tricuspid regurgitation is graded by using several qualitative and quantitative methods. The degree of regurgitation is classified as "none", "Mild", "Moderate" or "Severe".
-
Change in Tricuspid Valve (TV) Leaflet Coaptation Length From Baseline Through 6 Months Post-implant
Time frame: Baseline to Discharge (up to 5 days post-implant) and to 6 months post-implant
Change in the degree of TV leaflet coaptation length measured via echocardiography from Baseline through 6 months post-implant
-
Change in the Degree of Tricuspid Valve (TV) Leaflet Tethering Height From Baseline Through 6 Months Post-implant
Time frame: Baseline to Discharge (up to 5 days post-implant) and 6 months post-implant
Change in the degree of TV leaflet tethering height measured via echocardiography from Baseline through 6 months post-implant
Secondary outcomes
-
Change in the Right Ventricle (RV) Diastolic Area From Baseline Through 6 Months Post-implant
Time frame: Basline to Discharge (up to 5 days post-implant) and 6 months post-implant
-
Change in the Tricuspid Annular Diameter Measured at Diastole From Baseline Through 6 Months Post-implant
Time frame: Baseline to Discharge (up to 5 days post-implant) and 6 months post-implant
-
Change in the Right Ventricle (RV) Fractional Area From Baseline Through 6 Months Post-implant
Time frame: Baseline to Discharge (up to 5 days post-implant) and 6 months post-implant
-
Change in New York Heart Association (NYHA) Classification From Baseline Through 6 Months Post-implant
Time frame: Baseline to Discharge (up to 5 days post-implant) and 6 months post-implant
The New York Heart Association (NYHA) Functional Classification provides a simple way of classifying the extent of heart failure. It places patients in one of four categories based on how much they are limited during physical activity; the limitations/symptoms are in regard to normal breathing and varying degrees in shortness of breath and/or angina. NYHA I implies no limitations. NYHA II implies slight limitation of physical activity. NYHA III implies marked limitation of physical activity and finally, NYHA IV implies patients are Unable to carry on any physical activity without discomfort.
Sponsors and collaborators
Lead sponsor
Medtronic Cardiac Rhythm and Heart Failure
Industry
Registry information
Important dates
- Study start
- 2011
- Primary completion
- 2016
- Study completion
- 2016
- First posted
- Feb 15, 2012
- Registry last updated
- Aug 10, 2018
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Related clinical trials
Published trials that share one or more normalized conditions with this study.
Transcatheter Tricuspid Valve Interventions and Right Ventricular Function: Evaluation with Magnetic Resonance Imaging
NCT04522154
Cardiovascular Diseases, Heart Diseases
Bad Oeynhausen, North Rhine-Westphalia, Germany
View Trial DetailsTRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR
NCT03227757
Cardiovascular Diseases, Heart Diseases
Los Angeles, California, United States
View Trial DetailsTreatment of Tricuspid Valve Regurgitation in Patients Undergoing Left Ventricular Assist Device Implantation Study
NCT03775759
Cardiovascular Diseases, Heart Diseases
Durham, North Carolina, United States
View Trial DetailsLong-term Outcome After Isolated Tricuspid Valve Repair
NCT01537458
Cardiovascular Diseases, Heart Diseases
Leuven, Vlaams-Brabant, Belgium
View Trial Details